MODIFICATION
J -- RECOVERY-SanDiego-MECHANICAL-IMPROVEMENT - Amendment 14
- Notice Date
- 3/8/2010
- Notice Type
- Modification/Amendment
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- General Services Administration, Public Buildings Service (PBS), Los Angeles Service Center (9PXC), 300 North Los Angeles Street, Suite 2300, Los Angeles, California, 90017-5460
- ZIP Code
- 90017-5460
- Solicitation Number
- RECOVERY-SD-MECHANICAL-IMPROVEMENT
- Point of Contact
- Henry Huynh, Phone: 7147221498, Thuy Ta, Phone: 415-522-3603
- E-Mail Address
-
henry.huynh@gsa.gov, thuy.ta@gsa.gov
(henry.huynh@gsa.gov, thuy.ta@gsa.gov)
- Small Business Set-Aside
- N/A
- Description
- 3. CLARIFICATION: The synopsis of work (file name Overview of Work at Schwartz) document is intended as a broad overview only, and did not include all subordinate tasks. In particular, the work described in the Enovity scope of work was summarized only in terms of the controls work. However the demand control ventilation, motor replacement, and AHU VFD requirements (corresponding to contract price form CLINs 6, 7, 8) still apply to the project. In order to avoid confusion, the synopsis is revised to itemize this work. Q&A 3-8-10 set 5 Q&A 3-4-104 Set 3 & 4 1. Questions & answers are posted (two attachments - "Q&A 3-4-10 set 3 & 4" and "Q&A 3-8-10 set 5"). 2. CLARIFICATION: Section 15625 Centrifugal Water Chillers, paragraph 2.02 B, only applies to chiller number 3. 3. CLARIFICATION: The synopsis of work (file name Overview of Work at Schwartz) document is intended as a broad overview only, and did not include all subordinate tasks. In particular, the work described in the Enovity scope of work was summarized only in terms of the controls work. However the demand control ventilation, motor replacement, and AHU VFD requirements (corresponding to contract price form CLINs 6, 7, 8) still apply to the project. In order to avoid confusion, the synopsis is revised to itemize this work. 4. CHANGE: Chiller project, specification section 15269, VFD, page 15269.5, paragraph 2.02.F.11 - requirement for output filters on chiller VFDs is deleted.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/GSA/PBS/9PXC/RECOVERY-SD-MECHANICAL-IMPROVEMENT/listing.html)
- Place of Performance
- Address: Schwartz Federal Building and USCH: 880 Front Street, San Diego, CA, United States
- Record
- SN02085254-W 20100310/100308234120-679419c88100bb2e55dd64e34d9b520d (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)