MODIFICATION
H -- RECOVERY--H--PROJECT NUMBER 8840, Harry S Truman Dam And Reservoir, MO The Government will make one generating unit available for tuning at a time. Government personnel will be made available to assist as necessary.
- Notice Date
- 3/17/2010
- Notice Type
- Modification/Amendment
- NAICS
- 335314
— Relay and Industrial Control Manufacturing
- Contracting Office
- USACE District, Kansas City, ATTN: CENWK-CT, 700 Federal Building 60l East 12th Street, Kansas City, MO 64106-2896
- ZIP Code
- 64106-2896
- Solicitation Number
- W912DQ-10-T-0009
- Response Due
- 4/5/2010
- Archive Date
- 6/4/2010
- Point of Contact
- James D. Kindle, 660-438-7317
- E-Mail Address
-
USACE District, Kansas City
(james.d.kindle@usace.army.mil)
- Small Business Set-Aside
- N/A
- Description
- The Government will make one generating unit available for tuning at a time. Government personnel will be made available to assist as necessary. Normal working hours are Monday through Friday 06:00 a.m. to 4:30 p.m., excluding Federal Holidays. Work outside these hours requires approval in advance by the Power Plant Superintendent. Tuning of Unit #1 requires contractor to provide and install a new MLDT kit on blade servo Unit #1. Governor tuning requires checking Atlas controller inputs and outputs while monitoring controller software for correct response, calibrating all tunable parameters and sensors. During calibration or testing, the contractor shall investigate all abnormal governor control functions. Provide necessary Atlas controller programming to eliminate abnormalities. C.4.3 List of known abnormal governor functions and interfaces with other equipment. 1. Unit #1 - synchronization problem. Check governor parameters. 2. Unit #6 - Atlas controller requiring reboot after unit shutdown. 3. Unit #6 When loaded does shutdown with no alarms or operator input 4. Some governors let Unit over-speed slightly upon startup. 5. All Atlas controllers at various times Open GM breaker on selecting Stop from OIT causing load rejection instead of ramping down. (Units 3 and 4 mainly) C.4.4 Contractor shall provide 4 complete sets of as-left Governor programming sheets, neatly bound in 11x17 format and provide final report with calibration worksheets for each unit with status of unit in as-found condition and as-left condition within 30 days of completion of on-site service. C.4.5Contractor shall provide a work schedule estimate with quote. C.5.5 Contractual Line Items: 0001Furnish all labor to calibrate, program and diagnose (6) six Atlas controlled Woodward governors 0002Calibration report 0003Provide 4 copies of as-left Governor programming sheets BRAND NAME OR EQUAL: 0004Provide (1) one General Electric MLDT Slide Mounting device Kit, Part #211D6760G0001
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA41/W912DQ-10-T-0009/listing.html)
- Place of Performance
- Address: USACE District, Kansas City, Harry S Truman Lake Project 15968 Truman Road Warsaw MO
- Zip Code: 65355
- Zip Code: 65355
- Record
- SN02094671-W 20100319/100317234639-1f1de8f0729aba18ee1ae7d597bd0686 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |