Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF APRIL 01, 2010 FBO #3050
SOURCES SOUGHT

Z -- Install a Solar Micro Grid at Ft. Hunter Liggett, California

Notice Date
3/30/2010
 
Notice Type
Sources Sought
 
NAICS
237130 — Power and Communication Line and Related Structures Construction
 
Contracting Office
USACE District, Sacramento, 1325 J. Street, Sacramento, CA 95814
 
ZIP Code
95814
 
Solicitation Number
W91238-10-S-2455285-01
 
Response Due
4/13/2010
 
Archive Date
6/12/2010
 
Point of Contact
Charles S. Crivellaro, (916) 557-5182
 
E-Mail Address
USACE District, Sacramento
(charles.s.crivellaro@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
This is a SOURCES SOUGHT NOTICE for a Market Research ONLY to determine the availability of potential small business firms for a potential small business category type set-aside. NO AWARD will be made from this Sources Sought. NO SOLICITATION, SPECIFICATIONS, OR DRAWINGS IS AVAILABLE AT THIS TIME; therefore, do NOT request a copy of a solicitation. Potential offerors having the skill, capabilities and bonding necessary to perform the described project are invited to provide feedback via email to Mr. Charles S. Crivellaro at charles.s.crivellaro@usace.army.mil. All responses will be used to determine the appropriate acquisition strategy for a potential future acquisition. Particularly, the purpose of this NOTICE is to gain knowledge of potential small business sources to include small business in the following categories: Certified 8a, Certified HUB Zone, and Service-Disabled Veteran-Owned Small Business (SDVOSB), for a contract to install a Solar Micro Grid, Ft Hunter Liggett, California. The capabilities will be evaluated solely for the purpose of determining to Set-Aside for the Small Business Community or to conduct as an Unrestricted Procurement. Other than small businesses may respond to this NOTICE in the event the market does not indicate SB interest, however, preference will be given to the SB categories listed above. The government must ensure there is adequate competition among the potential pool of available contractors. This project is planned for advertising in April 2010. The estimated cost range according to the FAR 36.204 is between $5,000,000 and $10,000,000. The NAICS Code is 237130, the size standard is $14 million, and the Federal Supply Code is Y249, Other Utilities. Under Federal Acquisition Regulation (FAR) guidelines 52.219-14, the concern will perform at least 15% of the cost of the contract, not including the cost of materials, with its own employees. PROJECT DESCRIPTION Provide a one (1) Mega Watt Solar Power field on 6.3 acres to support a micro grid at the Cantonment. Power connections and meter to reroute excess energy back to the main grid. The micro grid will provide energy security by providing energy during electrical outages and provide energy cost savings by feeding back excess energy into the mail grid. Project includes compliance with the following processes: Renewable Energy Rebate Program, Renewable Energy Certificate Green Tag Program, Western Power Region/Utility Power Pool Coordination, EA, LEED Certification with Renewable Energy Rebate Compliance, Renewable Energy Certificate/Green Tag Compliance Metering, and 12 foot Support Structure for solar Renewable. Solar lighting and Security fencing are required. An all weather road is required to access the site in inclement weathers. A meter for verification and monitoring of usage and energy fed back to the power grid. AEWRS Data is current for Fort Hunter Liggett. All Fort Hunter Liggett Electric Power projects are being developed in full compliance and coordination with local commercial energy providers to ensure that all requirements are met, to include equipment, permitting and certifications. CAPABILITY STATEMENT The following requests are designed to apprise the US Army Corps of Engineers, Sacramento District, of any prospective construction contractors project execution capabilities. Please provide your response to the following. The submission is limited to 20 pages. 1) Offerors name, address, point of contact, phone number, and e-mail address. 2) Offerors interest in bidding on the solicitation when it is issued. 3) Offerors capability to perform a contract of this magnitude and complexity and comparable work performed within the past 5 years Describe your self performed effort, brief description of the project, customer name, timeliness of performance, customer satisfaction, and dollar value of the project) provide at least 3 examples. 4) Offerors type of small business and Business Size (Small Business, HUBZone, Service Disabled Veteran Owned and/or Small Business, 8(a)) 5) Offerors Joint Venture information if applicable existing and potential 6) Offerors Bonding Capability in the form of a letter from Surety The Capabilities Statement for this sources sought is not expected to be a Request for Proposal or Invitation for Bid, nor does it restrict the Government to an ultimate acquisition approach, but rather short statements regarding the companys ability to demonstrate existing-or-developed expertise and experience in relation to the areas specified herein. Any commercial brochures or currently existing marketing material may also be submitted with the Capabilities statement. Submission of Capabilities statement is not a prerequisite to any potential future offerings, but participation will assist the Corps of Engineers in tailoring requirements to be consistent with industry capabilities. This synopsis is for information and planning purposes only and is neither to be construed as a commitment by the Government nor will the Government pay for information solicited. Respondents will not be notified of the results of the evaluation. After completing its analysis, the Government will determine whether to limit competition among 8(a), Service Disabled Veteran, HubZone, or all Small Business firms or proceed with full and open competition as Unrestricted. Offers that do not meet all requirements or submit within the allotted time will not be considered. All interested contractors should notify this office in writing by email or mail by 5:00 PM Pacific Time on April 13, 2010. Submit response and information to: Mr. Charles S. Crivellaro CECT-SPK-A, Room 878 US Army Corps of Engineers-Sacramento District 1325 J Street Sacramento, CA 95814 or charles.s crivellaro@usace.army.mil
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA05/W91238-10-S-2455285-01/listing.html)
 
Place of Performance
Address: N/A N/A Ft. Hunter Ligget CA
Zip Code: N/A
 
Record
SN02106381-W 20100401/100330234854-cf4a2b75498a0d9d4a5aa09cd2607cf3 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers