SOLICITATION NOTICE
66 -- Low Background Shielding for Detecters in Gamma Spec
- Notice Date
- 4/16/2010
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- Idaho OperationsU.S. Department of EnergyIdaho Operations1955 Fremont AvenueIdaho FallsID83415
- ZIP Code
- 83415
- Solicitation Number
- DE-SOL-0001718
- Response Due
- 5/5/2010
- Archive Date
- 6/4/2010
- Point of Contact
- Minor, Kelleen L 208-526-0144, minorkl@id.doe.gov
- E-Mail Address
-
Minor, Kelleen L
(minorkl@id.doe.gov)
- Small Business Set-Aside
- N/A
- Description
- This amendment to the previous Presolicitation Notice provides the following changes: FROM: Presolicitation Notice TO: Combined Synopsis/Solicitation under the Commercial Item Test Program. The Radiological and Environmental Sciences Laboratory (RESL) has a requirement for eight (8) High Purity Geranium Gamma-Ray Detectors Shields. The specifications for these shields follow: The interior shield dimensions must have at least a 28-cm diameter by 40-cm height. The shield must be of a graded shield design that has at least 4 inches of solid-cast lead with at least O.5-mm of tin sheet liner and 1.6-mm copper sheet liner on the interior. The lead, tin and copper shield should be contained within at least 9.5 mm thick low-carbon steel casing. The bottom of the shield should have at least a 3.5-inch opening with a lead plug that will accommodate ORTEC X-COOLER systems. The shield should be supported on a rigid steel table with the dimensions approximately 2-ft x 2-ft by at least 30-in high. The shield must have access from the top with either a split or single opening door and must be easy to open and close. The shield must have access from the front with either a split or single open door and must be easy to open and have a latch that will keep the doors closed during use. The shield should include an installation and maintenance manual, touch-up paint and lifting eyes. The lid must stay shut when in use and the bidder should describe how this is achieved. Bids that contain shields constructed out of different materials than described in these specifications must demonstrate how they are equivalent to the 4-inch lead graded liner shield design and will also be considered. Bids must also include freight charges to Idaho Falls, Idaho. The bid that is most advantageous to the government will be selected.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DOE/PAM/HQ/DE-SOL-0001718/listing.html)
- Record
- SN02124626-W 20100418/100416235619-adf59c92c2a9ff5378c2e6fac4e25d88 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |