SOLICITATION NOTICE
Z -- N40083-10-R-0025; Repair Sampson Street Bridge at the Naval Station, Great Lakes, IL
- Notice Date
- 5/3/2010
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 237310
— Highway, Street, and Bridge Construction
- Contracting Office
- N40083 NAVFAC MIDWEST 201 Decatur Avenue Building 1A GREAT LAKES, IL
- ZIP Code
- 00000
- Solicitation Number
- N4008310R0025
- Response Due
- 6/4/2010
- Archive Date
- 6/7/2010
- Point of Contact
- Terryll Zade 847.688.2600 ext 417 Terryll Zade, 847.688.2600 ext 417Chris Payton, 847.688.2600 ext 171
- E-Mail Address
-
Contract Specialist
(terryll.zade@navy.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- N40083-10-R-0025, Design/Build Construction Contract Repair Sampson Street Bridge, Naval Station, Great Lakes, IL Phase I proposals due on June 4, 2010 @ 2:00 P.M. CST. This solicitation is being issued as a competitive Small Business set-aside for competition in Region V (Minnesota, Wisconsin, Illinois, Michigan, Indiana, and Ohio). This is a two-step design/build construction project for the Repair Sampson Street Bridge, Naval Station, Great Lakes, Request for Proposals, #N40083-10-R-0025. The proposed contract is limited to Small Businesses in Region V (Minnesota, Wisconsin, Illinois, Michigan, Indiana, and Ohio) of the Small Business Administration. The Government will not consider offers from large firms. Firms that are not serviced by Region V SBA District Offices, but have a bona fide place of business (as defined by SBA) within the geographic area served by Region V District Office's are also eligible to submit offers. Small Business firms not serviced by Region V SBA District Offices must consult its servicing District Office regarding the establishment of a bona fide place of business of status of a previously established bona fine place of business. All other firms are deemed ineligible to submit offers. PROJECT DESCRIPTION: It is the intent and objective of the Government to obtain design and construction services including labor, material, transportation, equipment and supervision required to design/build this construction project that will consist of repair by replacement of the Sampson Street Bridge (S9), which is a three span closed sprandrel concrete arch bridge that is approximately 345-ft long and 40-ft wide. The bridge will be removed to foundations and a new structure built on existing pier footings. The repaired bridge will contain above-deck elements of historic character, including historic street lamps and handrail with historic appearance. The period of performance is 555 days after notice to proceed. The NAICS Code for this proposed procurement is 237310 and the annual size standard is $33.5 million. This proposed solicitation is a Small Business Set-Aside. Estimated cost of this potential contract is between $7,000,000.00 and $10,000,000.00. Procurement Method: The solicitation utilizes source selection procedures which require offerors to submit a technical proposal, past performance and experience information, and a price (or cost) proposal for evaluation by the Government. The two phases consist of the following: PROPOSAL EVALUATION - PHASE 1 2.1Evaluation Factors - Phase 1. The areas of consideration for evaluation of technical proposals are detailed below. For evaluation purposes, Factors 1 through 3 are equal in importance. Phase I. Proposals will be evaluated on the following technical evaluation factors:.Factor 1 - Past Performance and Relevant Project Experience Sub-factor 1A - Design TeamSub-factor 2A - Construction Team.Factor 2 - Technical Qualifications Sub-factor 2A - Design TeamSub-factor 2B - Construction Team.Factor 3 - Management Approach Sub-factor 3A - Management ApproachSub-factor 3B - Construction Quality ControlSub-factor 3C - Safety & Experience Modifier Rate (EMR) The factors for Phase II are as follows: Factor 1 - Past Performance and Relevant Project Experience, Technical Qualifications and Management Approach (same as Phase I unless conditions change) Factor 2 - Technical Solutions Factor 3 - Durability, Maintainability, Sustainability of Bridge Factor 4 - Project Schedule and Phasing This is a new procurement. It does not replace an existing contract. No prior contract information exists. Phase I RFP is attached. Phase I proposals are due on June 4, 2010 at 2:00 P.M. Central Standard Time. Inquiries to Phase I RFP must be received no later than May 25, 2010. If you have any questions, please contact Terryll Zade, Contract Specialist, (847) 688-2600 ext 417 or via e-mail at terryll.zade@navy.mil.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/NAVFAC/N68950/N4008310R0025/listing.html)
- Place of Performance
- Address: Sampson Street BridgeNaval Station, Great Lakes, IL
- Zip Code: 60088
- Zip Code: 60088
- Record
- SN02138250-W 20100505/100503234339-ddd95621bace7a494b927960126dbb2b (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |