Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MAY 20, 2010 FBO #3099
SOLICITATION NOTICE

66 -- SPECTRORADIOMETER

Notice Date
5/18/2010
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
Department of Health and Human Services, Food and Drug Administration, Office of Acquisitions and Grants Services, 5630 Fishers Lane, Room 2129, Rockville, Maryland, 20857-0001
 
ZIP Code
20857-0001
 
Solicitation Number
1073272
 
Archive Date
6/18/2010
 
Point of Contact
WIKIKI HENTON, Phone: 4042531252
 
E-Mail Address
wikiki.henton@fda.hhs.gov
(wikiki.henton@fda.hhs.gov)
 
Small Business Set-Aside
Total Small Business
 
Description
Description: This is a combined synopsis/solicitation for commercial items prepared in accordance with FAR13 - Simplified Acquisition Procedures. This announcement constitutes the only solicitation, quotations are being requested, and a separate written solicitation document will not be issued. The North American Industrial Classification Code System (NAICS) for this procurement is 334516 with a business size standard of 500 employees. Background: The medical display laboratory of the Food and Drug Administration (FDA) performs measurements of performance characteristics of display devices and develops methods for the assessment of image quality using different display technologies and strategies. The laboratory is equipped with instrumentation that captures the optical emissions of display devices with high accuracy and precision and over a wide rage of conditions. The current spectroradiometer is not capable of measuring the spectral information in low light levels. Objective: The FDA requires a spectroradiometer capable of measuring ultra-low luminance levels of 0.0005 cd/m2 from various light-emitting devices and LCDs as well as performing high-accuracy measurements corresponding to scotopic relative luminosity. a measurement angle switching function should cover measurement angles of 0.1°, 0.2°, and 1°. The minimum measuring area should be smaller than a diameter of 0.5 mm and 0.1 mm with a close-up lens. The following specifications are required: Measurement angle includes 0.1°, 0.2° and 1° Measurement wavelength range: 380 to 780nm Spectral wavelength: <= 5nm Wavelength resolution: <= 1nm/pixel Median wavelength precision: <= ±0.3nm Luminance measurement range: 0.0005 to 5,000 cd/m2 Luminance Accuracy: <= ±2% Chromaticity Accuracy: x,y: <= ±0.002 (0.001 to 0.05 cd/m2) and x,y: <=±0.0015 (from 0.05 cd/m2) Repeatability of Luminance: <= 0.15% (0.05 to 5,000 cd/m2) Polarization error: <= 3% Color space mode Lv x y, Lv u' v', Lv TΔuv, XYZ,spectral waveform, dominant wavelength USB Communication Control software for analysis and reporting of data for MS Windows platforms Additional Requirements: 1. The instrument should have a factory warranty of one year and include additional (other than the original calibration that comes with the new instrument) calibrations traceable to the NIST light source to be used within a period of 2-3 years from the purchase date. 2. If the delvier time is more than 2 weeks, a temporary device shall be provided so that activities can get started in the laboratory. Line Item 0001: Spectroradiometer Quantity = 1 each Delivery: Delivery shall be FOB Destination. FDA shall not be responsible for any transit liability. Final Acceptance: Final acceptance shall be provided and payment in full shall be made upon receipt and acceptance of Line Item 0001. Evaluation Criteria and Basis for Award: Award will be made on a technically-acceptable, lowest-price basis. Technically-acceptable refers to meeting or exceeding the technical specifications delineated in this Solicitation and acceptable to the End User. Price shall not be evaluated on quotes that are determined not to be technically-acceptable. PROVISIONS AND CLAUSES The full text of a FAR provision or clause may be accessed electronically at www.acqnet.gov/far. The following provisions apply to this acquisition: 52.212-1 - Instructions to Offerors - Commercial; and 52.212-3 - Offeror Representations and Certifications - Commercial Items. In accordance with FAR 52.212-3 Offeror Representations and Certifications - Commercial Items, offerors must complete annual representations and certifications on-line at http://orca.bpn.gov. If paragraph (j) of the provision applies, a written submission is required; The following clauses apply to this acquisition: 1) 52.212-4 - Contract Terms and Conditions (Commercial Items); 2) 52.212-5 - Contract Terms and Conditions Required to Implement Statutes or Executive Orders (Commercial Items including subparagraphs); 3) 52.222-3 - Convict Labor; 4) 52.222-19 - Child Labor (Cooperation with Authorities and Remedies); 5) 52.222-21 - Prohibition of Segregated Facilities; 6) 52.222-26 - Equal Opportunity; 7) 52.222-36 - Affirmative Action for Workers with Disabilities; 8) 52.225-1 - Buy American Act-Supplies; 9) 52.225-13 - Restriction on Certain Foreign Purchases (E.O. 12722, 12724, 13059, 13067, 13121, and 13129); 10) 52.232-33 - Payment by Electronic Funds Transfer (Central Contractor Registration); and
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/HHS/FDA/DCASC/1073272/listing.html)
 
Place of Performance
Address: U.S. FOOD AND DRUG ADMINISTRATION, WHITE OAK CAMPUS, BUILDING 62, 10903 NEW HAMPSHIRE AVE., SILVER SPRING, Maryland, 20993, United States
Zip Code: 20993
 
Record
SN02152784-W 20100520/100518235044-996fe4c210fd406c7297ba9c8b078e6d (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |