AWARD
M -- RECOVERY--M--PROJECT NUMBER 2730, Carters Dam and Lake, GA Repair / Rehab Project Building in order to improve Energy Efficiency - Carter's Lake Project Office
- Notice Date
- 5/24/2010
- Notice Type
- Award Notice
- NAICS
- 561210
— Facilities Support Services
- Contracting Office
- USACE District, Mobile, P. O. Box 2288, 109 Saint Joseph Street (zip 36602), Mobile, AL 36628-0001
- ZIP Code
- 36628-0001
- Solicitation Number
- W91278-10-130-ARRA
- Archive Date
- 6/23/2010
- Point of Contact
- Alisa C. Murray, (251) 441-5578
- E-Mail Address
-
USACE District, Mobile
(alisa.c.murray@usace.army.mil)
- Small Business Set-Aside
- N/A
- Award Number
- W91278-06-C-0052, Mod P00043
- Award Date
- 5/21/2010
- Awardee
- MS TECHNOLOGY, INC. (877508770)<br> 137 UNION VALLEY RD<br> OAK RIDGE, TN 37830-8097
- Award Amount
- $587,684.00
- Line Number
- 0021
- Description
- RECOVERY - PER FAR 5.7 THIS NOTICE IS PROVIDED FOR INFORMATION PURPOSES ONLY; THEREFORE FAR 5.203 DOES NOT APPLY. THIS OPPORTUNITY WAS AVAILABLE ONLY TO CONTRACTOR(S) UNDER THE CURRENT CONTRACT NUMBER(S): MS Technology, Inc W91278-06-C-0052, Operations and Maintenance of Government Owned Facilities and Equipment This contract action was not awarded as a fixed price type because uncertainties involved in contract performance did not permit costs to be estimated with sufficient accuracy to use any type of fixed price contract. As such, a cost-reimbursement type action was awarded (FAR 16.301-2). The project number originally publized under this requirement was incorrect. Project Number 10973 is corrected to read Project Number 2730 Carter's Dam and Lake. Mod P00043 awarded against Contractor Number W91278-06-c-0052 requirements are: 1) For Project Office/Visitor Center: replacement of the staff break room cabinets and appliances; installation of a landscape irrigation system; improvements in thermal installation fenestration, hot water, electrical and security systems. 2) For Ranger Shop: Evaluate fire separation requirements between storage room and office in keeping with NFPA 101 requirements; Evaluate thermal resistance and vapor barrier; Provide on-demand in-line water heating. 3) For Operations and Maintenance Contractor Building: Provide exterior wall rating R 20 with ceiling rating R 30; Coordinate required resistance with as built and determine extend of required upgrades; Install insulation; Replace windows with high-efficient insulated units; Evaluate the existing HVAC System and redesign to meet federal, state and local codes; Evaluate the existing HVAC system for humidity contract and recommend and design upgrades.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA01/W91278-10-130-ARRA/listing.html)
- Record
- SN02157744-W 20100526/100524234134-dbc07ca5dd870d80ad4542895d8a6c85 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |