Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JUNE 09, 2010 FBO #3119
SOLICITATION NOTICE

66 -- High Temperature Environmental Chamber

Notice Date
6/7/2010
 
Notice Type
Presolicitation
 
NAICS
334519 — Other Measuring and Controlling Device Manufacturing
 
Contracting Office
Department of the Air Force, Air Force Materiel Command, 88 CONS/PK, 1940 ALLBROOK DRIVE, WRIGHT-PATTERSON AFB, Ohio, 45433-5309, United States
 
ZIP Code
45433-5309
 
Solicitation Number
FA8601-10-P-0438
 
Archive Date
7/6/2010
 
Point of Contact
Jennifer R. Begg, Phone: 9375222277
 
E-Mail Address
Jennifer.Begg@wpafb.af.mil
(Jennifer.Begg@wpafb.af.mil)
 
Small Business Set-Aside
N/A
 
Description
The United States Air Force, 88th Air Base Wing, Wright-Patterson AFB, Ohio 45433-5344 is preparing to solicit for a firm-fixed price contract for an environmental high temperature chamber. The contract line items will be firm-fixed price. Proposal equipment shall meet the requirements contained in the specifications below: 1. Quantity of one (1) environmental high temperature chamber must have the following characteristics. a. Digital control handset b. Optical glass window for use with optical and video extensometers c. Temperature range: -150° C to + 350° C d. Internal Height: 660 mm; Internal Width: 400 mm; Internal Depth: 400 mm e. External Height: 810 mm; External Width: 550 mm; External Depth: 930 mm f. High Door hinged on the left side of the chamber g. Line Voltage: 240 VAC single phase, 30 A, 50/60 Hz. Fitted with 250 V/30 A, NEMA L6-30P h. Removable Wedge option i. Chamber filler plug, for use Type C (5/8"), Type O (12 mm) or Type OO (6mm) pullrods. Plug inner diameter: 35 mm; plug outer diameter: 66.5 mm 2. Quantity of one (1) Cooling Options for environmental high temperature chamber a. LN2 Cooling Module b. LN2 Cooling Module w/ temperature range -150° C c. LN2 Coolant hose set, 2 meters ½ in BSP female on both ends d. Coolant Inlet Hose for LN2, 1.8 meters insulated PTFE hose with a ½ in BSP female and a CGA 295 female end 3. Quantity of one (1) Roller Carriage Mounting a. Roller Carriage Brackets for specific chamber b. Chamber roller bracket c. Frame mounting bracket d. Short support Leg (leg height adjustable 710 - 1360 mm 4. Quantity of one (1) Installation Half Day Installation of hardware/software by service representative Temperature Verification, In-Situ Method, Single Point Environmental Chamber or furnace. Temperature Verification, additional point We intend to award this contract sole source under the authority of FAR 6.302-1, Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements. All responsible sources may submit a capability statement which shall be considered. The proposed source is Instron, 825 University Avenue, Norwood, MA 02062-2643. At this time no small business set-aside is expected. NAICS Code 334519, Size Standard 500 employees. Refer all questions concerning this synopsis to Jennifer Begg, Contract Specialist, at 937-522-2277, fax at 937-656-1412, or email at jennifer.begg@wpafb.af.mil. An Ombudsman has been appointed to hear concerns from offerors or potential offerors during the proposal development. The purpose of the Ombudsman is to communicate contractor concerns, issues, disagreements, and recommendations to the appropriate director or contracting officer. Accordingly, the Ombudsman does not participate in the preparation of solicitations, the evaluation of the proposals, or the source selection process. Therefore, for routine matters on individual solicitations, please contact Jennifer Begg at the above number. When requested, the Ombudsman will maintain strict confidentiality as to the source of the concern. The Department of Defense (DoD) has determined the Central Contractor Registration (CCR) is the single DoD registration for contractors who conduct business or who are interested in conducting business with the DoD. Contractors must be registered in CCR prior to award for solicitations issued after 21 May 1998. You may contact CCR at 1-888-CCR-2423, fax at 1-703-696-0213. DUNS/CCR website: http://ccr.edi.disa.mil/ccr/cgi-bin/query.pl.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AFMC/88 CONS/FA8601-10-P-0438/listing.html)
 
Place of Performance
Address: WPAFB, Ohio, 45433, United States
Zip Code: 45433
 
Record
SN02170602-W 20100609/100607235158-f046cfad0c98bbbb8ef7af906bfe6220 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.