Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JULY 03, 2010 FBO #3143
MODIFICATION

59 -- RECOVERY - - 59--Sole Source Procurement of Station Progammable Logic Controller Equipment

Notice Date
7/1/2010
 
Notice Type
Modification/Amendment
 
NAICS
423610 — Electrical Apparatus and Equipment, Wiring Supplies, and Related Equipment Merchant Wholesalers
 
Contracting Office
USACE District, Savannah, P.O. Box 889, Savannah, GA 31402-0889
 
ZIP Code
31402-0889
 
Solicitation Number
W912HN-10-T-0048
 
Archive Date
7/26/2010
 
Point of Contact
Elaine D Parker, Phone: 912-652-5654
 
E-Mail Address
elaine.d.parker@usace.army.mil
(elaine.d.parker@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Description
RECOVERY - THIS NOTICE IS PROVIDED FOR INFORMATION ONLY. THIS OPPORTUNITY IS AVAILABLE ONLY TO CONTRACTORS UNDER W912HN-10-T-0048 - The U.S. Army Corps of Engineers, Savannah District, intends to award a sole source purchase order pursuant to 10 U.S.C 2304(c)(1) and FAR 6.302-1 to McNaughton-McKay Electric Company, 35 Old Mill Road, Greenville, SC 29607, for the supply of Allen Bradley Control Logix Equipment for Station Automation Control at the Hartwell Powerplant, Hartwell, Georgia. This procurement will be funded with American Recovery and Reinvestment Act (ARRA) Funds. This proposed award is for the procurement of Allen Bradley Programmable Logix Controllers (PLCs) to allow control and monitoring of the new Station Service Switchgear and Motor Control Centers at the Hartwell Project. The Hartwell Project, the Hydropower Technical Center, and the remaining Savannah District Hydroelectric Dams are using Allen Bradley PLCs that were provided by a previous contract as part of the governor upgrade for all of the generators at Hartwell and other hydroelectric power plants on the Savannah River. The PLCs have proven to be very reliable. The items purchased will monitor and control the new station service switchgear and Motor Control Centers, be programmed to interface with the plant SCADA system, and will communicate via the existing ControlNet network using DeviceNet and ControlNet Protocol. The Controller platform will be the backbone for the Plant Automation Project and must be compatible with existing equipment. The use of the Allen Bradley ControlLogix platform is required to communicate on the existing ControlNet network.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA21/W912HN-10-T-0048/listing.html)
 
Record
SN02194075-W 20100703/100701235202-b123ccb7b5a60392d7a684cefb96d58b (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.