59 -- Cafeteria Generator - Project # 060210-1
- Notice Date
- 7/26/2010
- Notice Type
- Modification/Amendment
- NAICS
- 238210
— Electrical Contractors and Other Wiring Installation Contractors
- Contracting Office
- Department of Labor, Employment Training Administration, Sierra Nevada Job Corps Center, 14175 Mt. Charleston Street, Reno, Nevada, 89506-1225
- ZIP Code
- 89506-1225
- Solicitation Number
- Project060210-1
- Archive Date
- 9/3/2010
- Point of Contact
- Len Taylor, Phone: 775-789-0817
- E-Mail Address
-
taylor.len@jobcorps.org
(taylor.len@jobcorps.org)
- Small Business Set-Aside
- Total Small Business
- Description
- 1) Disconnect and dismantle and remove existing 30 kW diesel powered emergency generator. Disposal of this generator is required. 2) Install and connect to the building electrical system, and connect to the building electrical system a new 60 kW, 120/208v, 3-phase diesel powered emergency generator, including battery, charger, starter, muffler, base-mounted fuel tank, generator main breaker and automatic transfer switch. All miscellaneous fittings, wiring, and connectors required to complete this installation must be provided. New generator shall be connected to provide back-up power for building exit signs, building emergency lights, and other critical loads such as cooking equipment, walk-in freezer(s), walk-in cooler(s), new hot water heating system, and heating system. New generator shall connected to provide back-up power for building exit signs, building emergency lights, and other critical loads such as cooking equipment, walk-in freezer(s), walk-in cooler(s), new hot water heating system, and heating system. 3) Contractor must provide a submittal for review and approval of the proposed equipment and installation being submitted in the bid document. 4) Once installation is completed, and full testing has insured the generator is properly working, the contractor must provide a minimum of two hours of training to SNJCC Maintenance Staff. 5) A minimum of one year warranty on the installation must be provided in writing by the contractor and a minimum of one year parts and labor warranty must be provided by the equipment manufacturer. There are no drawings available for this project. ADDENDUM #1 This Addendum forms a part of the Contract Documents and is issued for the purpose of changing the scope of work of this project and/or provides additional essential information. Acknowledge receipt of Addendum in the space provided on the Bid Form. Item # 1: Insure the normal power service to the cafeteria is adequately sized to handle the 200 amp emergency panels. Upgrade if necessary. Item # 2: Upgrade all wiring, as necessary, to handle the increased loads going from the existing 30kw generator to the new 60kw generator. This would include increasing the wire size form the transfer switch to the emergency panel. The new wiring should be capable of handling 200 amps, which the generator circuit breaker is rated at. The larger wire could then require larger conduit from the transfer switch to the emergency panel. Item # 3: It is recommended to provide two automatic transfer switches. One for emergency (i.e. emergency / exit lighting, etc) and one for non-emergency loads such as cooking equipment, walk-in coolers / freezers, ansul fire suppression system, and kitchen exhaust fans and air intake fans. Item # 4: Fuel tank capacity should allow operation of generator for a minimum of 72 hours. Item # 5: The bid opening date has been extended to Thursday,, August 19, 2010 at 10:30 AM.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DOL/ETA/sierranevadajcc/Project060210-1/listing.html)
- Place of Performance
- Address: 14175 Mt. Charleston St., building # 22, Reno, Nevada, 89506, United States
- Zip Code: 89506
- Zip Code: 89506
- Record
- SN02218220-W 20100728/100726235515-c21679d3f99a15ad59d597b256e58204 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |