SOLICITATION NOTICE

65 -- Audiology Equipment

Notice Date
8/9/2010
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
European Regional Contracting Office, ATTN:MCAA E, Building 3705, Landstuhl, Germany APO, AE 09180
 
ZIP Code
09180
 
Solicitation Number
W9114F10T0114
 
Response Due
8/20/2010
 
Archive Date
10/19/2010
 
Point of Contact
Christine Bauer-Newland, 011496371867597
 
E-Mail Address
European Regional Contracting Office
(christine.bauer-newland@amedd.army.mil)
 
Small Business Set-Aside
N/A
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. The solicitation number is W9114F-10-T- 0114. This solicitation is issued as a Request For Quotation, which incorporates provisions and clauses for commercial items in effect through Federal Acquisition Circular 2001-14. This is an unrestricted acquisition. The North American Industry Classification System (NAICS) code is 339112. The following Federal Acquisition Regulation (FAR) clauses and provisions apply to this acquisition: ITEM 0001, 1 Each Item#: 1761-9780-04, GSI 61 Audiometer w/ RS232 and printer port. 220V, 50Hz, BRAND NAME OR EQUAL ITEM 0002, 1 Each Item#: 1761-9650E English Language Kit BRAND NAME OR EQUAL ITEM 0003, 1 Each Addl. GSI 61 Instruction Manual, Item#: 1761-0100 BRAND NAME OR EQUAL ITEM 0004, 2 Each, GSI R1 service Manual Item#: 1761-0110 BRAND NAME OR EQUAL. ITEM 0005, 1 Each, High Performance Speakers for sound field testing. item#: 1761-9635, BRAND NAME OR EQUAL ITEM 0006, 1 Each, CD Player Item#: 1761-9621BRAND NAME OR EQUAL ITEM 0007, 1 Each, Paired Insert phones Item#: 1761-9606, Paired Insert phones BRAND NAME OR EQUAL. ITEM 0008, 1 Each, Tympstar Middle Ear Analyzer V2, Item#: 2000-9710-04, BRAND NAME OR EQUAL ITEM 0009, 1 Each, English Language Kit, Item#: 2000-9645E BRAND NAME OR EQUAL ITEM 0010, 1 Each, Addl.Tympstar User Manual, Item#: 2000-0100 BRAND NAME OR EQUAL ITEM 0011, 2 Each, Tympstar Service Manual, Item#: 2000-0110 BRAND NAME OR EQUAL ITEM 0012, 5 Each, Thermal Printer paper, Item#: 1700-9619 BRAND NAME OR EQUAL ITEM 0013, 3 Box, Eartip Set, Item#: TS212 BRAND NAME OR EQUAL ITEM 0014, 1 Each, Audera DPOAE Only, Item#: 2001-9731BRAND NAME OR EQUAL ITEM 0015, 1 Each, Addl. Audera manual for line item 0014 (1 included w/product) Item #: 2000-0100 BRAND NAME OR EQUAL ITEM 0016, 2 Each, Audera Service Manual, Item#: 2000-0110 for line item 0014 BRAND NAME OR EQUAL ITEM 0017, 1 Each, European, English Country Kit, Item#: 2001-9405 for line item 0014 BRAND NAME OR EQUAL ITEM 0018, 1 Each, Audera Laptop computer, Item#: 2001-9691for use with line item 0014 BRAND NAME OR EQUAL ITEM 0019, 1 Each, Laptop Cable Kit, Item#: 2001-9607 for use with line item 0014 BRAND NAME OR EQUAL ITEM 0020, 1 Each, Shipping to APO, Shipping, Ship directly to Vicenza, Italy 52.209-6, Protecting the Government's Interest When Subcontracting With Contractors Debarred, Suspended, or Proposed for Debarment, SEP 2006 52.222-19, Child Labor -- Cooperation with Authorities and Remedies, JUL 2010 52.222-50 Alt I, Combating Trafficking in Persons (Aug 2007) Alternate I, AUG 2007 52.225-13, Restrictions on Certain Foreign Purchases, JUN 2008 52.232-33, Payment by Electronic Funds Transfer--Central Contractor Registration, OCT 2003 52.233-3, Protest After Award, AUG 1996 52.233-4, Applicable Law for Breach of Contract Claim, OCT 2004 52.247-29, F.O.B. Origin, FEB 2006 252.203-7000, Requirements Relating to Compensation of Former DoD Officials, JAN 2009 252.203-7002, Requirement to Inform Employees of Whistleblower Rights, JAN 2009 252.211-7003, Item Identification and Valuation, AUG 2008 252.225-7041, Correspondence in English, JUN 1997 252.229-7000, Invoices Exclusive of Taxes or Duties, JUN 1997 252.232-7003, Electronic Submission of Payment Requests and Receiving Reports, MAR 2008 252.232-7008, Assignment of Claims (Overseas), JUN 1997 252.232-7010, Levies on Contract Payments, DEC 2006 252.233-7001, Choice of Law (Overseas), JUN 1997 ADDENDUM TO 52.212-4 ADDENDUM TO 52.212-1 52.252-2 Clauses Incorporated by Reference (Feb 1998) 52.252-6 Authorized Deviations in Clauses (Apr 1984) 252.212-7001 Contract Terms and Conditions Required to Implement Statutes or executive orders applicable to defense acquisitions of commercial items (APR 2010)(DEV) 252.229-7001 Tax Relief (JUN 1997) 252.229-7002 Customs Exemptions (Germany)(JUN 1997) ADDENDUM TO 52.212-1 INSTRUCTIONS TO VENDORS The following paragraphs are hereby amended: Para (a) Does not apply to this RFQ. Para (b) Replace subparagraph (4) with the following: (4)Technical Factor. The vendor must explain how you will comply with the requirements in the request for quote by submitting a written quote which describes: Salient Characteristics Standard - - Acceptable - - Unacceptable Line item 0001 GSI 61 Audiometer w/RS232 and printer port,, 1. All electrical components must be 220V/50Hz, 2. Offered Equipment must have Dual channel control with mixing/routing capability and be able to run clinic audiometric test batteries. 3. Offered Equipment must be able to test pure tone and speech,, 4. Offered Equipment must be compatible with AudBase Audiometric Software for uploading into AHLTA System. (Enerprise-wide medical and dental information management system for Military Health System) Line item 0008 Tympstar Middle Ear Analyzer V, 1. Offered Equipment must be 220V/50Hz, 2. Offered Equipment must allow simple one button test protocol selection. 3. Offered Equipment must provide default parameters per test mode, allow to alter set test parameters, automate desired test sequence, and enable multiple operators to set up their own default parameters.,, 4. Offered Equipment must provide capacity to test Admittance (Y), Susceptance (B) and Conductance (G) at 226, 678 and 1000 Hz probe tones.,, 5. Offered Equipment must provide the following features as a minimum: Tympanometry: Screening, Diagnostic, Two-Component Reflex: Threshold ETF: Intact TM, Perforated TM Reflex Decay ARLT Reflex Sensitization Multiple Frequency Program Mode, 6. Offered Equipment must be compatible with AudBase Audiometric Software for uploading into AHLTA System,, Line item 0014 Audera Hearing Analyzer 1.Offered Equipment must be 220V/50Hz,, 2. Offered Equipment must provide Distortion Product Otoacoustic Emissions Testing (DPOAE) Failure to receive an acceptable rating of any of the listed salient characteristics will result in an unacceptable technical rating unless the error(s), deficiency (ies) or omission (s) can be corrected. All CLINs shall be priced. If you fail to price all CLINs, your quote will not be considered for award. Para (c) Change 30 to 60. Para (d) Does not apply to this request for quote (RFQ). Para (i) Does not apply to this RFQ. Add the following: Para (m) Quotes shall describe how your system contains the salient characteristics and is an equal to the Labconco Logic Purifier Biosafety Cabinets and Stands. Para (n) ELECTRONIC QUOTES. Vendors may submit electronic quotes in response to this RFQ. The quote must arrive by the time specified in the RFQ to the following email address: Christine.bauer-newland@amedd.army.mil. Vendors may call Christine Bauer-Newland 06371-86-7597 to verify receipt of the quote. If the vendor chooses to email the quote, the Government will not be responsible for any failure of transmission or receipt of the quote, or any failure of the vendor to verify receipt of the emailed quote. Para (o) QUESTIONS. Prospective vendors are strongly encouraged to submit any questions regarding this RFQ two days before closing date of quote submission by e-mail to christine.bauer-newland@amedd.army.mil. All questions received will be answered officially through an amendment for distribution to all prospective vendors. SPECIAL NOTE: All offerors must be registered in the Central Contractor Registration (CCR) prior to award, and lack of registration shall make an offer ineligible for award. Offerors may obtain information on registration and annual confirmation requirements by calling 1-888-227-2423 or via Internet at http://www.ccr.gov/. All quotes are due 20 Aug 2010 before 5:00 p.m. Central European Time. Offers may be sent via email at christine.Bauer-Newland@amedd.army.mil, hand-delivered, or faxed to 011-49-6371-86-8070. The point of contact for this acquisition is Christine Bauer-Newland, phone no. 011-49-6371-86-7597.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/MEDCOM/DADA19/W9114F10T0114/listing.html)
 
Place of Performance
Address: European Regional Contracting Office ATTN:MCAA E, Building 3705 Landstuhl, Germany APO AE
Zip Code: 09180
 
Record
SN02234400-W 20100811/100809235818-eea26e05b268228875ee37b0dcccf836 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.