SOURCES SOUGHT
Z -- SOURCES SOUGHT - FY11 DLA MILCON PN DESC1190 ALTER FUEL STORAGE TANKS, HICKAM AIR FORCE BASE, OAHU, HAWAII
- Notice Date
- 9/10/2010
- Notice Type
- Sources Sought
- NAICS
- 237120
— Oil and Gas Pipeline and Related Structures Construction
- Contracting Office
- USACE District, Honolulu, Building 230, Fort Shafter, HI 96858-5440
- ZIP Code
- 96858-5440
- Solicitation Number
- W9128A-11-Z-0001
- Response Due
- 9/17/2010
- Archive Date
- 11/16/2010
- Point of Contact
- Maria Buckner, 808-438-8583
- E-Mail Address
-
USACE District, Honolulu
(maria.r.buckner@usace.army.mil)
- Small Business Set-Aside
- N/A
- Description
- This announcement constitutes a Sources Sought Synopsis (market survey). This is not a Request for Quote (RFQ) or a Request for Proposal (RFP). This announcement is for information and planning purposes only and is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or award a contract. The U.S. Army Corps of Engineers, Honolulu District is performing a market research for a construction requirement entitled: FY11 DLA MILCON PN DESC1190 Alter Fuel Storage Tanks, Hickam Air Force Base, Oahu, Hawaii. This requirement will be awarded as a firm-fixed price construction contract. The construction price range is between $5,000,000.00 and $10,000,000.00. The purpose of this sources sought is to determine interest and capability of potential qualified 8(a) small businesses, Historically Underutilized Business Zone (HUBZONE) small businesses and Service Disabled Veteran Owned Small Businesses (SDVOSBs) relative to the North American Industry Classification code (NAICS) 237120. The Small Business size standard for this NAICS code is $33.5 million average annual revenue. To make an appropriate acquisition decision for this project, the Government may use responses to this sources sought synopsis. The type of solicitation issued and the manner of advertisement may depend on the responses to this sources sought synopsis. SUBMISSION REQUIREMENTS FOR RESPONSES TO THIS SOURCES SOUGHT SYNOPSIS (1) Your intent to submit a proposal for this project when it is formally advertised (2) Name of firm with address, phone and point of contact. (3) CAGE Code and DUNS number (4) Size of firm including category of small business, such as 8(a), HUBZONE, or SDVOSB (5) Firms Bonding Capacity (6) Statement of Capability (SOC) stating your skills, experience, knowledge, and equipment required to perform the specified type of work. This should include documentation of past specialized experience and technical competence in performing similar projects, up to three (3) past projects for which your firm was the prime contractor. The SOC should be no more than two pages in length. Firms responding to this sources sought synopsis, who fail to provide ALL of the required information requested, will not be used to assist the Government in the acquisition decision, which is the intent of this sources sought synopsis. NOTE: IF YOU DO NOT INTEND TO SUBMIT A PROPOSAL FOR THIS PROJECT WHEN IT IS FORMALLY ADVERTISED, PLEASE DO NOT SUBMIT A RESPONSE TO THIS SOURCES SOUGHT SYNOPSIS. If inadequate responses are received, the solicitation may be issued for full and open competition. Where to send responses: Submit responses to Ms. Maria Buckner via email at maria.r.buckner@usace.army.mil Response deadline: September 16, 2010 at 4:00 p.m. (Hawaiian Standard Time) Place of Performance: Hickam Air Force Base, Oahu, Hawaii Requirement description for FY11 DLA MILCON PN DESC1190 Alter Fuel Storage Tanks, Hickam Air Force Base, Oahu, Hawaii: Provide labor, materials, permits and equipment to to perform work on fuel storage Tanks No. 1 and No. 2, Hickam Air Force Base, Oahu, Hawaii. Work shall include but not be limited to: installation of floating pans; install high-high and low level alarms; install service platforms; install a secondary concrete dike containment; restore stairs in tank area; replace hand-operated fuel recovery system with electrical operated pump; install tank piping in dike area; construct building for existing emergency stand-by generator; perform related demolition work; replace high level control valve and float control; install ATG water probe and slotted still well; install roof access manway/ladder; install roof access hatch to install floating pans; install cathodic protection system for issue lines. Other information: The solicitation will be posted to the Federal Business Opportunities web site (www.fbo.gov) when released. Proposals will be due approximately 30 days after the actual solicitation issuance date.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA83/W9128A-11-Z-0001/listing.html)
- Place of Performance
- Address: HICKAM AIR FORCE BASE HICKAM AFB HONOLULU HI
- Zip Code: 96858-5440
- Zip Code: 96858-5440
- Record
- SN02276101-W 20100912/100910235246-c5e95290005ccf454febefb463397d44 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |