10 -- INFANT WARMERS

Notice Date
9/16/2010
 
Notice Type
Modification/Amendment
 
NAICS
339113 — Surgical Appliance and Supplies Manufacturing
 
Contracting Office
European Regional Contracting Office, ATTN:MCAA E, Building 3705, Landstuhl, Germany APO, AE 09180
 
ZIP Code
09180
 
Solicitation Number
W9114F10T0139
 
Response Due
9/21/2010
 
Archive Date
11/20/2010
 
Point of Contact
Christine Bauer-Newland, 011496371867597
 
E-Mail Address
European Regional Contracting Office
(christine.bauer-newland@amedd.army.mil)
 
Small Business Set-Aside
N/A
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. The solicitation number is W9114F-10-T-0139. This solicitation is issued as a Request For Quotation, which incorporates provisions and clauses for commercial items in effect through Federal Acquisition Circular 2001-14. This is an unrestricted acquisition. The North American Industry Classification System (NAICS) code is 339113 The following Federal Acquisition Regulation (FAR) clauses and provisions apply to this acquisition: ITEM 0001, 7 EACH Giraffe Bedded Warmer; General Item Description:Radiant warming units designed to provide thermal stability to infants while allowing direct observation. Units can be operated either with the heating elements turning on and off according to the changes in the infant's skin temperature (automated mode) or by setting the heater at a constant power level for a set period of time (manual mode). These units are available in several different configurations, including freestanding and mounted on an integral bassinet to facilitate continuous thermal support for newborns and critically ill infants; they are also used for infants undergoing long treatment in a cool environment. Detailed item Description: Item#M1118179, Giraffe BW SPO2 T-Piece Resus Bedded Warmer which consists of the following componets: M1111951:Giraffe Bedded Warmer with elevating base and aimable procedure light; M1111958: Masimo SpO2 Option -Probe Panel with patient temperature probe, Masimo SpO2 and in bed-scale connections; M1111959:Giraffe In-Bed Scale; M1111965:T-Piece Resuscitation System with blender and high pressure yokes; M1111967: DISS Inlet Fittings; M1111976:Standard Single Drawer; M1117756: English Language Version - Warmer, Masimo SpO2 and T-Piece Resuscitation Manuals and Labels; M1112018: Disposable Patient Probe; M1150616: Kit, Service Manual, Giraffe-Panda iRES Warmers, M1150617: Service manual Kit, Giraffe-Panda Resuscitation System; German Power Cord 220V, 2 prong; 2 ea operators and service manuals in English, all electrical components need to be 220V-50Hz. BRAND NAME OR EQUAL ITEM 0002, 7 EACH Item#6700-0458-804, 8 IN Oxygen Assembly DISS H-I-T; BRAND NAME OR EQUAL ITEM 0003, 7 EACH Item#6700-0458-803, 8 IN Air Hose Assembly DISS H-I-T; BRAND NAME OR EQUAL ITEM 0004, 7 EACH Item#6600-0513-801, Instrument Shelf 12in x 12in, Center Mounted; BRAND NAME OR EQUAL. ITEM 0005, 7 EACH Item#6600-0851-800, Rotating IV Pole BRAND NAME OR EQUAL ITEM 0006, 7 EACH Item#M1091316, T-Piece Disp w/Mask Size 0, Pack of 10; BRAND NAME OR EQUAL ITEM 0007, 7 EACH Item#M1091335, T-Piece Disp, Pack of 10; BRAND NAME OR EQUAL. ITEM 0008, 7 EACH Item#M1091365, T-Piece Disp w/Mask Size1, Pack of 10; BRAND NAME OR EQUAL ITEM 0009, 7 EACH Item#6600-0837-800, Tubing Management Arm; BRAND NAME OR EQUAL ITEM 0010, 7 EACH Item#6600-0853-800, Silo Support; BRAND NAME OR EQUAL ITEM 0011, 7 EACH Item#6600-1793-500,Corner Tray - SE and NW; BRAND NAME OR EQUAL ITEM 0012, 7 EACH Item#6600-1794-500,Corner Tray - SW and NE; BRAND NAME OR EQUAL ITEM 0013, 7 EACH Item#6600-0873-700, Giraffe Disposable probe (box of 10); BRAND NAME OR EQUAL ITEM 0014, 7 EACH Item# M1121896, Infant Care Installation Fee; BRAND NAME OR EQUAL SHIPPING ADDRESS: Direct Shipment Door-to-Door to: Landstuhl Regional Medical Center Attn: Anne Braxton Property Management Branch Geb 3739 66849 Landstuhl Kirchberg 52.209-6, Protecting the Government's Interest When Subcontracting With Contractors Debarred, Suspended, or Proposed for Debarment, SEP 2006 52.222-19, Child Labor -- Cooperation with Authorities and Remedies, JUL 2010 52.222-50 Alt I, Combating Trafficking in Persons (Aug 2007) Alternate I, AUG 2007 52.225-13, Restrictions on Certain Foreign Purchases, JUN 2008 52.232-33, Payment by Electronic Funds Transfer--Central Contractor Registration, OCT 2003 52.233-3, Protest After Award, AUG 1996 52.233-4, Applicable Law for Breach of Contract Claim, OCT 2004 52.247-34, F.O.B. Destination, NOV 1991 252.203-7000, Requirements Relating to Compensation of Former DoD Officials, JAN 2009 252.203-7002, Requirement to Inform Employees of Whistleblower Rights, JAN 2009 252.211-7003, Item Identification and Valuation, AUG 2008 252.225-7041, Correspondence in English, JUN 1997 252.229-7000, Invoices Exclusive of Taxes or Duties, JUN 1997 252.232-7003, Electronic Submission of Payment Requests and Receiving Reports, MAR 2008 252.232-7008, Assignment of Claims (Overseas), JUN 1997 252.232-7010, Levies on Contract Payments, DEC 2006 252.233-7001, Choice of Law (Overseas), JUN 1997 ADDENDUM TO 52.212-4 ADDENDUM TO 52.212-1 52.252-2 Clauses Incorporated by Reference (Feb 1998) 52.252-6 Authorized Deviations in Clauses (Apr 1984) 252.212-7001 Contract Terms and Conditions Required to Implement Statutes or executive orders applicable to defense acquisitions of commercial items (APR 2010)(DEV) 252.229-7001 Tax Relief (JUN 1997) 252.229-7002 Customs Exemptions (Germany)(JUN 1997) ADDENDUM TO 52.212-1 INSTRUCTIONS TO VENDORS The following paragraphs are hereby amended: Para (a) Does not apply to this RFQ. Para (b) Replace subparagraph (4) with the following: (4)Technical Factor. The vendor must explain how you will comply with the requirements in the request for quote by submitting a written quote which describes: Salient Characteristics Standard - - Acceptable - - Unacceptable 1. Offered System must provide un-interrupted thermal support 2. Offered System must provide integrated resuscitation capability. 3. Offered System must provide integrated SpO2 capability with Masimo SET Technology. 4. Offered System must have integrated in-bed scale with weight range from 300g to 8 kg (0.66 lbs to 17.6 lbs) 5. Offered System must be 220V/50Hz. 6. Offered System must provide aimable procedure light and built-in dimmable observation lights. Failure to receive an acceptable rating of any of the 6 technical factors will result in an unacceptable technical rating unless the error(s), deficiency (ies) or omission (s) can be corrected. All CLINs shall be priced. If you fail to price all CLINs, your quote will not be considered for award. Para (c) Change 30 to 60. Para (d) Does not apply to this request for quote (RFQ). Para (i) Does not apply to this RFQ. Add the following: Para (m) Quotes shall describe how your system contains the six salient characteristics and is an equal to the GE GIRAFFE BEDDED WARMER W/ACCESSORIES Para (n) ELECTRONIC OFFERS. Vendors may submit electronic quotes in response to this RFQ. The quote must arrive by the time specified in the RFQ to the following email address: Christine.bauer-newland@amedd.army.mill Vendors may call Christine Bauer-Newland 06371-86-7597 to verify receipt of the quote. If the vendor chooses to email the quote, the Government will not be responsible for any failure of transmission or receipt of the quote, or any failure of the vendor to verify receipt of the emailed quote. Para (o) QUESTIONS. Prospective vendors are strongly encouraged to submit any questions regarding this RFQ two days before closing date of quote submission by e-mail tochristine.bauer-newland@amedd.army.mil, or Fax 06371-86-8070. All questions received will be answered officially through an amendment for distribution to all prospective vendors. ACQUISITION PROCEDURE This is a commercial item under FAR Part 12 and the acquisition procedures to be used for this purchase will be in accordance with FAR Part 13. SPECIAL NOTE: All offerors must be registered in the Central Contractor Registration (CCR) prior to award, and lack of registration shall make an offer ineligible for award. Offerors may obtain information on registration and annual confirmation requirements by calling 1-888-227-2423 or via Internet at http://www.ccr.gov/. All quotes are due 21 Sep 2010 before 5:00 p.m. Central European Time. Offers may be sent via email to christine.Bauer-Newland@amedd.army.mil, hand-delivered, or faxed to 011-49-6371-86-8070. The point of contact for this acquisition is Christine Bauer-Newland, phone no. 011-49-6371-86-7597.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/MEDCOM/DADA19/W9114F10T0139/listing.html)
 
Place of Performance
Address: European Regional Contracting Office ATTN:MCAA E, Building 3705 Landstuhl, Germany APO AE
Zip Code: 09180
 
Record
SN02285756-W 20100918/100917000637-a857ad9eaa5b1c61bd32a02098d5da83 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.