Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF SEPTEMBER 22, 2010 FBO #3224
MODIFICATION

Y -- Amendment to Bldg 1219 Remodel/Renovation Solicitation.

Notice Date
9/20/2010
 
Notice Type
Modification/Amendment
 
Contracting Office
Fort Carson DOC, Directorate of Contracting, 1676 Evans Street, Building 1220, 3rd Floor, Fort Carson, CO 80913-5198
 
ZIP Code
80913-5198
 
Solicitation Number
W911RZ-10-B-0017
 
Response Due
9/24/2010
 
Archive Date
11/23/2010
 
Point of Contact
Nicole Mintus, 526-0368
 
E-Mail Address
Fort Carson DOC
(nicole.mintus@us.army.mil)
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
The purpose of this amendment is to 1.Incorporate a Question and Answer sheet for all questions compiled on 14 Sept 2010 for Contractor Information. 2.To revise section 804.15 In-House Performance Plan of the solicitation section 800, by deleting sentence ~Submit with proposal a plan for accomplishing at least 15% of work with its own employees.~ 3.Incorporate three new drawings (Roof Plan Barracks Wing& Second Floor, Shower Specifications, AND Roof plan Mess Wing) into clause 252.236-7001Contract Drawings and Specifications. 4.Incorporate revised drawings (Civil Details C-1.1 and Site Plan C-1.0). Bidders are urged to review the drawings as it addresses new work. 5.Incorporate excel spreadsheet labeled Door Schedule, which was left out of the original posting for 1219. 6.Note to bidders: When you open the ~Finished Schedule/Legend~ document, you will need to refer to both tabs for the Schedule and Legend. 7.Note to Bidders: The following requirement is incorporated into Drawing M-4.0(Center Wing Existing Mechanical): Some of the existing pipes and equipment in the Mechanical Room are identified to remain for reuse. After abatement (removal) of existing insulation has been completed on the existing domestic hot, cold, and return water pipes, the boiler supply and return pipes that are to remain for reuse in the Mechanical Room, Contractor shall re-insulate with 1inch thick Flexible closed cell foam pipe insulation sealing all joints. The existing horizontal Hot Water Storage Tank shall be re-insulated with 1inch thick Flexible closed cell foam insulation, and seal all joints. 8.Note to Bidders: Please refer to question 31 on the answer and question page for additional requirements for the bathrooms in Bldg 1219. 9.All other terms and conditions remain unchanged.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/fa246a6dbcc5e479b233e0c13092ef18)
 
Place of Performance
Address: Fort Carson DOC Directorate of Contracting, 1676 Evans Street, Building 1220, 3rd Floor Fort Carson CO
Zip Code: 80913-5198
 
Record
SN02288977-W 20100922/100920235002-fa246a6dbcc5e479b233e0c13092ef18 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.