AWARD
41 -- REMOVE AND INSTALL TWO (2) LIEBERT HVAC UNITS AT THE NWS WFO LOCATED IN PLEASANT HILL, MO
- Notice Date
- 9/20/2010
- Notice Type
- Award Notice
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- Department of Commerce, National Oceanic and Atmospheric Administration (NOAA), Eastern Region Acquisition Division-KC, 601 East 12th Street, Room 1756, Kansas City, Missouri, 64106, United States
- ZIP Code
- 64106
- Solicitation Number
- NWWR40001018462CMM
- Archive Date
- 10/3/2010
- Point of Contact
- Carey M. Marlow, Phone: (816)426-7460
- E-Mail Address
-
carey.m.marlow@noaa.gov
(carey.m.marlow@noaa.gov)
- Small Business Set-Aside
- Total Small Business
- Award Number
- WC133W10SE3817
- Award Date
- 9/18/2010
- Awardee
- THE WILSON GROUP INC, PO BOX 546<br />, LEES SUMMIT, MO 64063, LEES SUMMIT, Missouri 64063, United States
- Award Amount
- $94,784.00
- Line Number
- 0001
- Description
- RECOVERY - IN COMPLIANCE WITH THE TRANSPARENCY AND ACCOUNTABILITY REQUIREMENTS ASSOCIATED WITH THE SUPPLEMENTAL APPROPRIATIONS PROVIDED BY THE AMERICAN RECOVERY AND REINVESTMENT ACT (ARRA), PUBLIC LAW 111-5, THE DEPARTMENT OF COMMERCE, NATIONAL OCEANIC AND ATMOSPHERIC ADMISISTRATION (NOAA), EASTERN ACQUISITION DIVISION - KANSAS CITY (EAD-KC) ANNOUNCES THE AWARD OF CONTRACT NUMBER WC133W-10-SE-3817 TO THE WILSON GROUP INC. OF LEES SUMMIT, MO TO COMPLETELY REPLACE TWO (2) LIEBERT HVAC UNITS AT THE NATIONAL WEATHER SERVICE (NWS), WEATHER FORECAST OFFICE (WFO) LOCATED AT 1803 NORTH 7 HIGHWAY, PLEASANT HILL, MO 64080. DESCRIPTION: This serves as notice of award of Contract Number WC133W-10-SE-3817 to Conditioned Air Mechanical of Grand Island, NE to completely replace two (2) Liebert HVAC units at the National Weather Service (NWS), Weather Forecast Office (WFO) located in Pleasant Hill, MO. Work to be performed will consist of the following: • RECOVERY - Supply and install (2) each new 15 ton Liebert Digital Model # DSO53ADAOE1216A Scroll Down-flow cooling systems. • With all features listed below on a per unit basis. • 460v/3ph/60Hz, 5000 amps rms short Circuit Current rating. • 14 ga. welded frame with Autophoretic coating. The frame can be separated for installation. (IBM off white color). • Down-flow Supply Air (Bottom)/ Return Air (Top). Exterior panels insulated and powder coated. • 4" filters w/MERV 8 Ratings. • Centrifugal blower, minimum 200,000 hrs L3 permanently lubricated pillow block bearings. Static regain duct attached to bottom of blower with • 3hp motor with open drip proof NEMA premium efficiency • Infrared Humidifier w/ automatic flush cycle Capacity of 11lbs/hr • (3) Three stage, finned tubular, 304/304 SS electric reheat w/15KW BTUH Capacity. • Crankcase heaters. • Liquid lines filter driers, refrigerant site glasses, expansion valves and liquid line solenoid valves. • Two (2) independent Digital Scroll Compressors provide variable capacity. (3yr. Warranty) • A-frame evaporator coil with stainless steel drain pain. • R-407C refrigerant. • Dual fixed-pitched motor sheaves, dual fixed-pitched fan pulleys, dual belts and automatic belt tensioning system. (5yrs warranty) • iCom control system with the ability to connect both units together/Lead-Lag • and compatible to set up with the Automatic Logic system for controls with Icom service bracket. And large display. • Non-Locking disconnect switch. • Smoke sensor with unit alarms and shutdown. Includes supervision contacts • Dual Refrigerant Circuits. With hot gas mufflers. • Floor stands with turning vane for floor stand. • Intellislot 485 Card (OC485-LBDS) Delivers Modbus communications capabilities. • Liebert manufactured outdoor Fan-Speed condenser designed for 100F outdoor ambient. • High Temp. Sensor shuts down at 125 F degree. • Fan speed control (Lee Temp) on condenser for operation -30F (208V/3ph/60hz) • Condenser disconnect switch. • Water detector alarm system. • Control Unit requirements: Standby- unit on, Low Suction pressure, Loss of Power, Firestat on. • Dual Float condensates pump w/ alarm sensor. • LT410 Point leak sensor. • 12" floor stand with turning vane for stand. • New Piping will be an ACR copper with 50/50 silver solder joints. Hot gas lines to be insulated. • New electrical to new systems. • Evacuate refrigerant from existing Lieberts system. (Do not reuse refrigerant). • Recover refrigerant and oil and provide disposal according to EPA guidelines. • Remove and properly dispose of old unit. • Evacuate and recharge system to manufacturer's specifications. • Warranty (5) years on compressor, all other parts and labor (1 year). This notice is for full disclosure compliance and announcement of potential subcontracting opportunities only. Original Point of Contact: Carey Marlow, Contract Specialist, Phone: (816) 426-7460, FAX (816) 274-6923, Email: carey.m.marlow@noaa.gov. Questions of a technical nature should be referred to Mark Betsch, Project Manager, (816) 268-3156, Email: mark.betsch@noaa.gov
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DOC/NOAA/CASC/NWWR40001018462CMM/listing.html)
- Place of Performance
- Address: NWS WFO PLEASANT HILL, MO, 1803 NORTH 7 HIGHWAY, PLEASANT HILL, MO 64080, PLEASANT HILL, Missouri, 64080, United States
- Zip Code: 64080
- Zip Code: 64080
- Record
- SN02289636-W 20100922/100920235634-100bbb502e22dd6b95ac3d3c076e157b (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |