SOLICITATION NOTICE
J -- This service to include preventive maintenance, repair and technical support for thirty (30) MINICAMS, Chrome-Net system, CHROM-LINK systems, and Stream Selection Systems in support of the ECBC Environmental Monitoring Laboratory.
- Notice Date
- 9/27/2010
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 811219
— Other Electronic and Precision Equipment Repair and Maintenance
- Contracting Office
- RDECOM Contracting Center, Aberdeen Installation Contracting (RDECOM-CC), Directorate of Contracting, 4118 Susquehanna Avenue, Aberdeen Proving Ground, MD 21005-3013
- ZIP Code
- 21005-3013
- Solicitation Number
- W91ZLK10T0518
- Response Due
- 9/29/2010
- Archive Date
- 11/28/2010
- Point of Contact
- Stacy R. Copeland, 410-278-5472
- E-Mail Address
-
RDECOM Contracting Center, Aberdeen Installation Contracting (RDECOM-CC)
(stacy.r.copeland@us.army.mil)
- Small Business Set-Aside
- N/A
- Description
- This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. The MINICAMS systems are used for analyzing Chemical Warfare Agents in the air. All repair parts, consumable supplies, travel, per diem, and report costs are also covered in the contract cost. The service to be performed on a semi-annual basis will include but is not limited to: " Functional testing of the MINICAMS electronics circuits and aligning pressure-transducer and electrometer circuits. " Cleaning the GC module and inlet system by back flushing them with solvents. " Checking GC module gas flows. " Replacing the preconcentrator tube, cleaning the inlet valve, and testing the gas inlet system for leaks. " Upgrading MINICAMS software ( with authorization and after testing is completed to ensure no communication problems) " Adjusting operation parameters and installing minor engineering upgrades as required. " Functional testing of the overall system by calibrating and challenging the system with an appropriate compound. " Verify error-free communications on the CHROM-NET air monitoring data network. " Check hard drive for errors and free space of the CHROM-NET air monitoring data network central processing unit.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/067eb094b79b20c854acbafa401f0722)
- Place of Performance
- Address: RDECOM Contracting Center, Aberdeen Installation Contracting (RDECOM-CC) Directorate of Contracting, 4118 Susquehanna Avenue Aberdeen Proving Ground MD
- Zip Code: 21005-3013
- Zip Code: 21005-3013
- Record
- SN02297733-W 20100929/100927234421-067eb094b79b20c854acbafa401f0722 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |