Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF OCTOBER 01, 2010 FBO #3233
SOLICITATION NOTICE

66 -- Award to be made by SAIC-F under prime contract with the NCI-F. There will be no privity of contract between the seller and the Government (see description for further detail). Request for Quotation for Initiator Exp Microwave System or equivalent

Notice Date
9/29/2010
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
Department of Health and Human Services, National Institutes of Health, Science Applications International Corporation, Building 1050, Boyles Street, Frederick, Maryland, 21702
 
ZIP Code
21702
 
Solicitation Number
A57328
 
Archive Date
10/22/2010
 
Point of Contact
Shelly K. Hollinger, Fax: (301) 846-5311
 
E-Mail Address
hollingersk@mail.nih.gov
(hollingersk@mail.nih.gov)
 
Small Business Set-Aside
N/A
 
Description
This procurement is being solicited for award by SAIC-F under its contract #HHSN261200800001E for Operations and Technical support at the National Cancer Institute-Frederick, a federally funded research and development center. SAIC-F is the prime contractor charged with operations and technical support of the government owned contractor operated (GOCO) facility. Please provide a price quote for the following items. 1) 1 each Part number 355302, Initiator Exp Microwave System includes Crimper and Decapper, process vials start up kit including: ten 0.2-0.5ml vials, twenty 0.5-2ml, twenty 2-5ml vials, twelve 10-20ml vials, caps, reseal septa and stir bars, adaptor pack including: ten adapters for 0.2-0.5ml vials and twelve adapters for 10-20ml vials 2) 1 each Part number SER-IN1-IN, Installation and training for Initiator 1 includes 1/2 day field service site visit for installation, start-up and training 3) 1 each Part number 352016, microwave vials, 0.5-2ml, 100/case includes 100 process vials; 107 caps and reseal septa and 107 magnetic stir bars 4) 1 each Part number 351521, Microwave vials, 2-5ml, 100/case includes 100 process vials; 107 caps and reseal septa and 107 magnetic stir bars 5) 1 each part number 354833, Microwave vials, 10-20ml, 50/case, includes 50 process vials, 55 caps and reseal septa and 5 magnetic stir bars Specifications: 1) Compact system 2) Must be able to safely process reaction volume from 0.2ml to 20ml at up to 250C and 20-bar overpressure 3) Must have a built-in temperature and pressure sensors to allow real time monitoring and full control of the reaction 4) Ensures optimal heating efficiency through out the full volume range, with up to 400W of output power. 5) Must have a safety lock system with triple tier safety to ensure maximum operator safety at all times. 6) Includes stepwise parameter control and user set stirring speed 7) Instrument includes full start up kit 9) The catalog number listed are Biotage. 10) Offerors are requested to quote on the items as specified or an equivalent. For an equivalent, complete specifications and/or descriptive literature will be provided with the response. Offerors are requested to indicate any differences from the specifications listed. Failure to provide complete information may cause offer to be non-responsive. 11) Warranty shall commence upon date of installation, integration, validation, and/or final acceptance. Warranty period shall be ________ months, including parts, labor and travel 12) Vendor must provide a copy of the software license agreement or any other supplemental contractual requirement. 13) SAIC-Frederick, Inc. is eligible for Federal Supply Schedule pricing. 14) All offers must be F.O.B. destination, and freight may be paid or prepaid and add. 15) Any shipping charges must be identified and listed on the response for evaluation. 16) Partial offers will not be accepted. 17) Offerors agrees to make delivery of the quoted items in _________ days after receipt of order 18) If any freight charge exceeds $250.00 a separate invoice must be sent. A copy of the actual freight bill must be included with the invoice. This freight invoice from the shipper/freight forwarder must be received before the shipping charges can be paid by SAIC Frederick, Inc. 19) Offeror must provide a certificate of insurance.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/HHS/NIH/NCIFCRF/A57328/listing.html)
 
Place of Performance
Address: NCI-Frederick, SAIC-Frederick, Inc., Bldg 1050, Frederick, Maryland, 21702, United States
Zip Code: 21702
 
Record
SN02301929-W 20101001/100929235858-86527f5798a512aea1697175db25bac4 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers