Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF OCTOBER 24, 2010 FBO #3256
SOLICITATION NOTICE

Y -- Presolicitation NoticeSummary Statement of WorkFor the Construction of Tactical Operations Center

Notice Date
10/22/2010
 
Notice Type
Presolicitation
 
Contracting Office
RCO Bavaria (PARC Europe, 409th CSB), Attn: AEUCC-G, Unit 28130, APO, AE 09114-8130
 
ZIP Code
09114-8130
 
Solicitation Number
W912PB10R8004
 
Response Due
11/8/2010
 
Archive Date
1/7/2011
 
Point of Contact
Solinsky, 00499641838726
 
E-Mail Address
RCO Bavaria (PARC Europe, 409th CSB)
(christian.solinsky@eur.army.mil)
 
Small Business Set-Aside
N/A
 
Description
Presolicitation Notice Summary Statement of Work For the Construction of Tactical Operations Center 1.CHARACTERISTICS OF BUILDING (as per design plans): a.Total area (approximates): 444 m2 i.Area 1 (gross): 226 m2 ii.Area 2 (gross): 200 m2 iii.Passage gallery (adjoining walkway): 18 m2 b.Number of floors: 1 story c.Building height: 4.7 m d.Floor height to suspended ceiling: 3.1 m e.Roof type: Gabled 2. BRIEF DESCRIPTION OF FACILITY: a.Overall: This shall be new construction on an existing site. Foundation is a newly emplaced concrete foundation with stub-ups for all required facility utilities. b.Facility: Pre-engineered building procured and erected by the awarded contractor. "Exterior walls and roof are to be two-layered sandwich -type panels. "Interior partitions and walls shall be constructed of gypsum boards mounted on metal studs/framework and filled with industrial wool or other suitable material. "A proper lightning arresting system must be installed. Components protruding from the roof must be connected into the arresting system. c. Layout: "Area 1 contains 2 ea individual offices, 2 each training classrooms, 2 ea communal office spaces, 1 male and 1 female restroom, and a mechanical room, "Area 2 contains 1 ea Operations Center, 2 ea secret connection rooms, 1 individual office, 1 planning room, 1 electrical room, 1 server room and 1 storage room. d.Heating, Ventilation and Air Conditioning: Technical characteristics of all ventilation systems are presented in document No. 240-TP-SV-TCH (attached). e.Electrical: General capacity of all electrical devices for the facility: 41.0 kW. All electrical devices shall be supplied with 400/230 V voltage power with frequency of ~50 Hz. Uninterrupted power supply shall be ensured for fire alarm system and computer networks. f.Communications: A computer network system of category 5e is planned in the designed building. The computer network shall meet the following: cable-laying standards: ISO/IEC 11801, CENELEC EN50173, ANSI/EIA/TIA-568A and its annexes; standards on methods of laying cables: ANSI/EIA/TIA-569; testing standards: EIA/TIA TSB 67.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/a693f4a20b630c2b329f43cacde3141a)
 
Place of Performance
Address: RCO Bavaria (PARC Europe, 409th CSB) Attn: AEUCC-G, Unit 28130, APO AE
Zip Code: 09114-8130
 
Record
SN02315936-W 20101024/101022234125-a693f4a20b630c2b329f43cacde3141a (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.