66 -- AUTOMATED MICROPLATE READER AND ACCESSORIES

Notice Date
11/4/2010
 
Notice Type
Presolicitation
 
NAICS
423450 — Medical, Dental, and Hospital Equipment and Supplies Merchant Wholesalers
 
Contracting Office
US Army Medical Research Acquisition Activity, ATTN: MCMR-AAA, 820 Chandler Street, Frederick, MD 21702-5014
 
ZIP Code
21702-5014
 
Solicitation Number
W81XWH11T0013
 
Response Due
11/22/2010
 
Archive Date
1/21/2011
 
Point of Contact
Suzanne Rogers, 301-619-7631
 
E-Mail Address
US Army Medical Research Acquisition Activity
(suzanne.rogers@us.army.mil)
 
Small Business Set-Aside
N/A
 
Description
Basic Description: The request is for an automated microplate reader that provides superior flexibility and sensitivity for the definition, finetuning and validation of the wide range of assays and reagents. A reader that supports a broad range of microplate-based detection assays for primary and secondary screening; enzymatic assays including kinase and protease assays; G protein coupled receptor assays; ion channel-related assays; receptor-ligand binding studies and other molecular interaction assays; cell-based assays; DNA/RNA quantification; and applications based on UV fluorometry. Minimum Essential Characteristics: 1.Premium Quad4 Monochromator technology that reduces stray light down to 2 x 10-7, improves spectral blocking, brings more light onto the sample and the detector, and includes a flash lamp with 2 x more power. 2.A flexible wavelength selection from UV to NIR with high accuracy and adjustable bandwidth settings for fine adjustments towards the fluorophore. 3.High speed recording for excitation, emission, and absorbance spectra in the fast scanning mode. 4.Rapid 3D scanning enabling characterization of unknown samples, and Z-focusing in all top reading modes. 5.A well Scanning mode, heated Incubation from +4C to 42C, and linear or orbital shaking in 3 speeds. 6.Accommodates 6, 12, 24, 48, 96, 384 and 1536 well plate formats. Includes ability to measure wavelength range of in tunable 1nm increments with software-selectable variable bandwidth. 7.Fast ratiometric measurements immediate changes in wavelength in FRET assays and change of polarization direction within one millisecond for FP measurements. 8.On-board control buttons for instant start/stop control of pre-programmed measurement workflows. 9.A luminescence module that provides access to single and dual color luminescence measurements, glow and flash luminescence with three fibers adapted for 96-well, 384-well and 1,536-well plates. 10.Optional injectors with variable syringe size, volume and speed settings. 11.Flexibility a.Wavelength/Bandwidth/Accuracy (fluorescence intensity) i.Wavelength selection Premium Quad4 Monochromators ii.Wavelength range 1.Excitation: 230 nm 850 nm 2.Emission: 280 nm 850 nm iii.Bandwidth Adjustable 1.less than 300 nm: 2.5 nm 10 nm 2.greater than 300 nm: 5 nm 20 nm iv.Wavelength accuracy 1.Less than 300 nm: 0.5 nm 2.greater than 300 nm: 1 nm v.Wavelength precision 1.less than 300 nm: 0.5 nm 2.greater than 300 nm: 1 nm b.Wavelength/Bandwidth/Accuracy (absorbance) i.Wavelength selection Double monochromator ii.Wavelength range 230 nm 1,000 nm iii.Bandwidth 2.5 nm below 300 nm, 5 nm above iv.Wavelength accuracy 1.less than 300 nm: 0.5 nm 2.greater than 300 nm: 1 nm v.Wavelength precision 1.less than 300 nm: 0.5 nm 2.greater than 300 nm: 1 nm vi.Measurement range 0 4 OD vii.Linearity 0 3 OD: R2 greater than 0.999 @ 280 nm and 492 nm viii.Accuracy at 492 nm 1 OD: less than 0.5 % and 0.006 OD ix.Precision at 492 nm 1 OD: less than 0.5 % and 0.006 OD 12.Sensitivity a.Fluorescence sensitivity values i.Fluorescence top reading 384-well plate 0.17 fmol / well ii.Fluorescence bottom reading 384-well plate 2 fmol / well iii.TRF 384-well plate 10 amol / well Europium (100 flashes) iv.FP 384-well plate 2 mP standard deviation @1 nM Fluorescein b.Luminescence sensitivity values i.Glow luminescence 384-well plate 0.7 fmol ATP / well ii.Flash luminescence 384-well plate less than 80 amol ATP / well
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/USAMRAA/DAMD17/W81XWH11T0013/listing.html)
 
Place of Performance
Address: US Army Medical Research Acquisition Activity ATTN: MCMR-AAA, 820 Chandler Street Frederick MD
Zip Code: 21702-5014
 
Record
SN02322754-W 20101106/101104234354-859b180529f80f3e35a6bdaadc23bd48 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.