Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF NOVEMBER 25, 2010 FBO #3288
SOURCES SOUGHT

61 -- Station Service Transfer Bus Circuit Breaker Replacement, 27KV SF6 Circuit Breakers A136 and N136

Notice Date
11/23/2010
 
Notice Type
Sources Sought
 
Contracting Office
Bureau of Reclamation - LC - Lower Colorado Regional Office P.O. Box 61470 Boulder City NV 89006
 
ZIP Code
89006
 
Solicitation Number
11-007LC
 
Response Due
12/7/2010
 
Archive Date
11/23/2011
 
Point of Contact
Brooke Mena Contracting Specialist 7022938489 bmena@usbr.gov;
 
E-Mail Address
Point of Contact above, or if none listed, contact the IDEAS EC HELP DESK for assistance
(EC_helpdesk@NBC.GOV)
 
Small Business Set-Aside
N/A
 
Description
THIS IS A SOURCES SOUGHT ANNOUNCEMENT ONLY. If a solicitation is released, it will be synopsized and posted at www.FedBizOpps.com. The Bureau of Reclamation, Lower Colorado Region, is conducting market research to ascertain if there are small businesses which have the capability to design, manufacture, and install 2 station service circuit breakers at Hoover Dam. The circuit breakers to be manufactured and installed will be rated at 27KV and will be rated to interrupt 128,000 amps (rms; symmetrical) fault current. The work requirement also requires removal of existing circuit breaker equipment. All interested businesses are encouraged to respond to this announcement no later than December 7, 2010, 4:30 PM PST. Please submit all requested documentation listed below to: Brooke Mena, Bureau of Reclamation, P.O. Box 61470, Boulder City, Nevada 89006-1470 or via email, bmena@usbr.gov. Interested parties should submit a capabilities package demonstrating the ability to perform the principal components of work listed above. Packages should include the following information: (1) Business name, address, business size and type (8a, HUBZone, Service Disabled Veteran, Small Business, Large Business, etc.) (2) a positive statement of your intention to submit an offer for this requirement as a prime contractor, and (3) demonstration of your firm's experience shown by providing a list of actual jobs completed within the past five years, including a listing of specific projects where circuit breakers rated to interrupt 128,000 amps (rms) or more and rated at 27 KV or higher were designed and installed by your firm. Additionally, for each circuit breaker installation listed, provide the following: a brief description of the work performed, project title, dollar amount for your work, which parts of the work were the responsibility of sub contractors, and the plant (or facility) name & location. In addition, a customer's contact name and phone number should be included, for each circuit breaker installation listed, to provide a reference knowledgeable of the work completed. Also, include attachments cataloging your firm's equipment assets, personnel resources, and financial resources that demonstrate your firm's responsibility and capability to perform the required work. Responsible sources having relevant experience and the capabilities to perform the work will be considered. The applicable North American Industry Classification System (NAICS) code is 335313, "Breakers, Power, manufacturing", and the related small business size standard is 1,000 employees. The estimated dollar magnitude of this project is anticipated to be between $3,000,000 and $4,000,000. It is anticipated that the contract duration will be approximately two (2) years in duration. Central Contractor Registration (CCR) and Annual Representations and Certifications, as required by FAR 4.1102 and 4.1201, will apply to this procurement. Prospective contractors must be registered prior to award. Lack of registration in the CCR database will make an offeror ineligible for award. Information on CCR registration can be obtained via the Internet at http://www.ccr.gov. Information on Annual Representations and Certifications can be obtained via the Internet at http://orca.bpn.gov.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/324cc1f69fb030be4ee710fa91123bb8)
 
Place of Performance
Address: Hoover Dam and Powerplant
Zip Code: 89005
 
Record
SN02332407-W 20101125/101123234106-324cc1f69fb030be4ee710fa91123bb8 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers