Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF DECEMBER 04, 2010 FBO #3297
AWARD

Z -- RECOVERY--Z--PROJECT NUMBER 5790, Fall River Lake, KS

Notice Date
12/2/2010
 
Notice Type
Award Notice
 
NAICS
237990 — Other Heavy and Civil Engineering Construction
 
Contracting Office
USACE District, Tulsa, ATTN: CESWT-CT, 1645 South 101st East Avenue, Tulsa, OK 74128-4609
 
ZIP Code
74128-4609
 
Solicitation Number
W912BV-09-R-1010
 
Archive Date
1/1/2011
 
Point of Contact
Phyllis O. Jordan, 918 832-4120
 
E-Mail Address
USACE District, Tulsa
(phyllis.jordan@usace.army.mil)
 
Small Business Set-Aside
N/A
 
Award Number
W912BV-09-D-1010, TO 0001, 000105
 
Award Date
11/22/2010
 
Awardee
HARTMAN-WALSH CORPORATION (008908568) <br> 7144 N MARKET ST<br> SAINT LOUIS, MO 63133-1899
 
Award Amount
$4,835.50
 
Description
RECOVERY - PER FAR 5.7 THIS NOTICE IS PROVIDED FOR INFORMATION PURPOSES ONLY; THEREFORE FAR 5.203 DOES NOT APPLY. THIS OPPORTUNITY WAS AVAILABLE ONLY TO CONTRACTOR(S) UNDER: Multiple Award Task Order Contract (MATOC) As part of Operations and Maintenance, Army, Recovery Act, this modification has been issued to Hartman Walsh Painting Company, to perform the following work: Fall River Lake--Repair Cracked Weld on Tainter Gate No. 6: 1.1 Provide labor, materials and equipment to repair the two cracked welds identified on the gusset plates attached to the east trunnion arm cross brace on tainter gate No. 8. Work includes: Provide labor, material and equipment to remove the attached gussett plates and remove all rust by grinding or mechanically cleaning and check condition of the braces. After cleaning and removal of all pack rust is completed make the necessary preparations to re-weld in the same location new 1/2-inch thick A36 steel gusset plates with the same type of weld as previously used. The final step will be to seal all sides and of the plates with a single pass weld on all open edges. 1.2 All steel repairs shall follow specification 05 05 50 of the original contract. All welds, procedures, qualifications, personnel etc., shall conform to the original construction specifications section 05 05 50 and as directed from the USACE Tulsa District EC-DC. All replaced steel components shall be properly prepared and painted per specification 099702 section.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA56/W912BV-09-R-1010/listing.html)
 
Record
SN02337172-W 20101204/101202234134-aaf7a4d873abb372ffda93b173edcc3d (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.