DOCUMENT
65 -- Heart Valve Durability Test System - SFVAMC - Attachment
- Notice Date
- 12/8/2010
- Notice Type
- Attachment
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- VA Northern California HealthCare System;150 Muir Road;Martinez CA 94553
- ZIP Code
- 94553
- Solicitation Number
- VA26111RQ0047
- Response Due
- 12/15/2010
- Archive Date
- 1/14/2011
- Point of Contact
- Angela Oppenheimer
- E-Mail Address
-
Contract Specialist
(angela.oppenheimer@va.gov)
- Small Business Set-Aside
- N/A
- Description
- This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotations are being requested and a written solicitation will not be issued. The simplified acquisition procedures of FAR Part 13 will be used in conjunction with commercial items procedures of FAR Part 12. NAICS code is 339112, size standard is 500 employees. This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2005-46 effective October 29, 2010, and VAAR rewrite dated 12/08/2009. Only emailed requests received directly from the requester are acceptable. This solicitation is requesting a ViVitro Hi-Cycle System, or equal. This accelerated pulse duplicator system is used for testing the durability of different bioprosthetic heart valves. It.# Qty/UPDescription Unit PriceExtended Price 11 EAHi-Cycle System for $ __________ $ __________ Accelerated cycling of Heart Valves ViVitro HCS4991 or equal 2 1 EAData Acquisition and $ __________ $ __________ Control System Computer and Hardware Hi-Test H10 Software System Win XP Pro or Win 7 Pressure Measuring System AP9991 ViVitro HCDA2010 or equal 3 1 EALaboratory Cart for Hi-Cycle $ __________ $ __________ With cooling fan assembly ViVitro HCCART or equal 4 1 EAPS-700 Stroboscope with $ __________ $ __________ Universal Voltage Charger ViVitro PS-700 or equal 5 1 EAPressure Reference - $ __________ $ __________ Digital Manometer ViVitro M200-DN0200 or equal GRAND TOTAL: $ ____________ Salient characteristics of required system: o Must be able to test multiple samples simultaneously. o Excitation waveform and cycle rate must be adjustable. o Real-time pressure monitoring of each chamber must be provided using software and proper transducers. o Mounting washers suitable for implantation of prosthetic valves should be included. o Fluid contact areas should be made from corrosion resistant materials. o Viewports should be included in the system to be able to view prostheses within the chambers. o Controlled temperature unit should be included to run the system in ambient and 37 ºC. Please specify any promotional or trade-in allowances, if available. DELIVERY SCHEDULE San Francisco VA Medical Center, 4150 Clement Street, San Francisco, CA 94121 Offeror proposed delivery date: _______________ Days ARO FOB Destination: Shipping costs must be included in unit prices; no separate shipping charges allowed. Only electronic offers will be accepted. Offers are due to angela.oppenheimer@va.gov by 4:00 PM. Pacific Time, December 15, 2010. SOLICITATION PROVISIONS/CONTRACT CLAUSES: "FAR 52.212-1 Instructions to Offerors - Commercial Items (Jun 2008). "FAR 52.212-3 Offeror Representations and Certifications -- Commercial Items (Oct 2010): oOfferors must include a completed copy of the provision with its offer or fill out online representations and certifications at https://orca.bpn.gov/. "FAR 52.212-4 Contract Terms and Conditions -- Commercial Items (Jun 2010). "FAR 52.212-5 Contract Terms and Conditions Required To Implement Statutes Or Executive oOrders -- Commercial Items (Oct 2010) For the purposes of this clause items (b) 4, 19, 20, 21, 22, 23, 25, 32, 33(ii), 41 are considered checked and apply. "FAR 52.232-38 Submission of Electronic Funds Transfer Information with Offer (May 1999) "FAR 52.252-1 - Solicitation Provisions Incorporated by Reference (Feb 1998); for the purpose of this provision, the fill-in's are https://www.acquisition.gov/far/index.html and http://www1.va.gov/oamm/oa/ars/policyreg/vaar/ respectively. "FAR 52.252-2 - Clauses Incorporated by Reference (Feb 1998); for the purpose of this clause, the fill-in's are https://www.acquisition.gov/far/index.html and http://www1.va.gov/oamm/oa/ars/policyreg/vaar/ respectively. "VAAR 852.203-70 Commercial Advertising (Jan 2008) "VAAR 852.211-70 Service Data Manuals (NOV 1984) (a) 811.107(a) "VAAR 852.246-71 Inspection (Jan 2008) "VAAR 852.273-76 Electronic Invoice Submission (Interim-October 2008)
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VANCHCS/VANCHCS/VA26111RQ0047/listing.html)
- Document(s)
- Attachment
- File Name: VA-261-11-RQ-0047 VA-261-11-RQ-0047.doc (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=165817&FileName=VA-261-11-RQ-0047-000.doc)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=165817&FileName=VA-261-11-RQ-0047-000.doc
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA-261-11-RQ-0047 VA-261-11-RQ-0047.doc (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=165817&FileName=VA-261-11-RQ-0047-000.doc)
- Record
- SN02340522-W 20101210/101208234037-b9532145d58a3f4985280a47f450357c (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |