FBO DAILY ISSUE OF JANUARY 13, 2011 FBO #3337
SOLICITATION NOTICE

Y -- Replace two existing variable frequency drives

Notice Date
1/11/2011
 
Notice Type
Presolicitation
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
General Services Administration, Public Buildings Service (PBS), Acquisition Services (7PQC), 819 Taylor St., Fort Worth, Texas, 76102, United States
 
ZIP Code
76102
 
Solicitation Number
GS-07P-11-UK-M-0030
 
Archive Date
2/10/2011
 
Point of Contact
Judy P. Tidwell, Phone: 8179783040, Janis A. Gaulden, Phone: 8179783040
 
E-Mail Address
judy.tidwell@gsa.gov, janis.gaulden@gsa.gov
(judy.tidwell@gsa.gov, janis.gaulden@gsa.gov)
 
Small Business Set-Aside
Total Small Business
 
Description
SUMMARY OF WORK FURNISH LABOR, MATERIALS, AND SUPERVISION TO REPLACE TWO EXISTING VARIABLE FREQUENCY DRIVES AT THE R.C. WHITE FEDERAL BUILDING, 700 EAST SAN ANTONIO AVE., EL PASO, TEXAS 01. STATEMENT OF WORK A. SCOPE: Provide all labor, material, equipment and supervision necessary to perform all work required for the replacement of two (2) variable frequency drives in accordance with the specifications. B. PURPOSE: (1) The purpose of this project is to replace two (2) existing Variable Frequency Drives, 100 Horsepower each. C. MAJOR ITEMS OF WORK: The project includes but is not limited to the following items: (1) Remove existing panels, Variable Frequency Drives (VFDs), wiring and hardware as necessary to accommodate the new hardware, wiring and new VFDs. (2) Furnish and install new VFDs. New Variable Frequency Drives are to be for the HVAC units (fans) and are to be 100 HP. Units are to be ABB Inc., ACH550 or equivalent with bypass designed specifically for the HVAC service. (3) Units must have bypass and manual operational capabilities. (4) Installation shall include enclosure cabinets, hardware and all modifications required for installation in existing motor control center. (5) Provide all connections and programming to connect to the existing Building Automation System. (6) Provide and install service disconnects. (7) Provide start-up and operational checks, training and operating manuals. (8) All work must be done after-hours and must not interfere with the operation of the building HVAC system. (9) Contractor must not start any on-site work before the materials, supplies and equipment are received and on site. The Contractor shall submit a written schedule to the COR for approval before any work is to begin on this project. (10) All hardware and equipment must be fully compatible with the existing control equipment system. Use of additional relays and components for integration is not allowed.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/GSA/PBS/7PMO-EP/GS-07P-11-UK-M-0030/listing.html)
 
Place of Performance
Address: R.C. WHITE FEDERAL BUILDING, 700 EAST SAN ANTONIO AVE, EL PASO, Texas, 79901, United States
Zip Code: 79901
 
Record
SN02358522-W 20110113/110111234606-09188cf0bc52207120b467d6c5a9a488 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.