Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF FEBRUARY 02, 2011 FBO #3357
MODIFICATION

Z -- Repair Electrical System, B2145 (PH2)

Notice Date
1/31/2011
 
Notice Type
Modification/Amendment
 
NAICS
237130 — Power and Communication Line and Related Structures Construction
 
Contracting Office
Department of the Air Force, Air Combat Command, 9 CONS, 6500 B St Ste 101, Beale AFB, California, 95903-1712
 
ZIP Code
95903-1712
 
Solicitation Number
FA4686-11-R-0006
 
Archive Date
2/25/2011
 
Point of Contact
Howard Gregory, Phone: (530) 634-3409
 
E-Mail Address
howard.gregory@beale.af.mil
(howard.gregory@beale.af.mil)
 
Small Business Set-Aside
N/A
 
Description
The Air Force is conducting a MARKET SURVEY to determine the interest and capability of potential offerors to project BAEY 110166P1, Repair Electrical System, B2145 (PH2). It is anticipated that this acquisition will be offered for full and open competition (unrestricted) subject to the North American Industry Classification System (NAICS) code 237130, with a corresponding size standard of $33.5M. 8(a), HUBZone, Service-Disabled Veteran-Owned Small Business, and Women-owned Small Business are encouraged to participate. This is a sources sought notice for planning purposes only, and there will be no pre-announcement of when the solicitation will be available. The work shall consist of the furnishing of all labor, materials, supplies, equipment, engineering expertise, transportation, supervision, and all other resources necessary to accomplish this two-part project which will complete the replacement of all existing building power centers with new mini-substations. Part 1 design and engineering work consists of: 1) engineering studies including a load study, short circuit analysis, protective device coordination analysis, voltage stability study, and arc fault analysis, and, 2) preparation of an electrical panels schedule, equipment monitoring report, Uninterruptable Power Supply (UPS) systems evaluation, power fluctuation troubleshooting and design improvement plan, associated electrical drawing as-builts, and all necessary submittals. Part 2 construction work consists of: The supply and installation of 3 ea mini-sub pairs to replace the existing power centers, a new 2000KW generator and load bank, distribution panels and associated control, switching, and backup power equipment, and infrastructure improvements to facilitate a safe and consistent electrical power supply. An attached, draft project-specific Statement of Work forms a part of this market survey, and provides additional details regarding this description of the work. Notice: This is very specialized medium-high voltage work requiring close engineering and construction coordination to ensure the project is completed within the period of performance without any unscheduled electrical power interruptions. Prior experience with medium-high voltage substations is essential. The work site is an active military facility where the contractor will be subject to strict security and operational restrictions. Magnitude of Construction: The estimated magnitude of the project is between $5,000,000 and $10,000,000. Responses should include the following: (1) a positive statement of your intention to submit a bid for this solicitation as a Prime Contractor; (2) listing of experience in work similar in type and scope to include contract numbers, project titles, dollar amounts, points of contact with their phone numbers, and an explanation of the relevancy of the project; (3) documentation from surety or their agent of your capability to be bonded for bid, performance and payment bonds for this project Please limit responses to 5 pages, and include your CAGE Code on your response. If your firm is interested in supplying a proposal for this project, please contact the Contract Administrator Howard Gregory via email, phone, or facsimile as noted below. Positive responses by prospective offerors are requested by this Sources Sought Announcement closing time/date of 3:00 PM PST on Thursday, 10 Feb 2011. This is NOT a request for proposal, and does not constitute any commitment by the Government. Responses to this sources sought notice will be used by the Government to make appropriate acquisition decisions. All interested sources must respond to future solicitation announcements separately from responses to this market survey. The solicitation will be posted on the Federal Business Opportunities website (https://www.fbo.gov/) and no paper copies will be provided. Notice to Offerors: Funds are not presently available for this project. No award will be made under this solicitation until funds are available. The Government reserves the right to cancel this solicitation, at any time prior to award of a contract.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/ACC/9CONS/FA4686-11-R-0006/listing.html)
 
Place of Performance
Address: 9th Contracting Squadron, 6500 B Street, Suite 101, Beale AFB, CA 95903-1712, Beale AFB, California, 95903, United States
Zip Code: 95903
 
Record
SN02369475-W 20110202/110131233855-4d097daf7117fd7b1279efccb98173e3 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.