Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF FEBRUARY 20, 2011 FBO #3375
SOLICITATION NOTICE

99 -- U.S. EPA - RFQ for One (1) Autoclave

Notice Date
2/18/2011
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
339114 — Dental Equipment and Supplies Manufacturing
 
Contracting Office
HPODUS Environmental Protection AgencyHeadquarters Procurement OperationsAriel Rios Building1200 Pennsylvania Avenue, NWWashingtonDC20460USA
 
ZIP Code
00000
 
Solicitation Number
PR-OCSPP-11-00044
 
Response Due
3/4/2011
 
Archive Date
4/3/2011
 
Point of Contact
Stefan Martiyan
 
E-Mail Address
Stefan Martiyan, Contract Specialist
(martiyan.stefan@epa.gov)
 
Small Business Set-Aside
N/A
 
Description
The U.S. Environmental Protection Agency (EPA), Office of Acquisition Management (OAM) has a requirement for the purchase of one (1) autoclave. The autoclave will replace an existing non-operational unit, which will be used for the Select Agent (Bacillus anthracis)-registered laboratory in order to decontaminate biohazardous materials. THIS IS A REQUEST FOR QUOTE. The current autoclave is a Steris Amsco Century SG-120. Its inner dimensions are 20" x 20" x 38". Its outer dimensions are 46" x 30" x 76.5". The unit has a single power door and is not recessed through a wall. The replacement autoclave must fit into the footprint of the Steris Amsco Century SG-120 and have the same utility requirements. This is essential because of the amount of space available, the location of the exhaust canopy, the floor drain, and the electric supply location cannot be changed. In accordance with FAR Subpart 11.104, this item is being solicited on a brand name or equal purchase basis. The brand name is Steris Corporation. A general description of the requirement's salient characteristics is as follows: 1.Unit must have a chamber size of approximately 20" x 20" x 38".2.Unit must have outer dimensions similar to 46" x 30" x 76.5" so that it fits into the current unit's footprint and so that all other salient characteristics are still met.3.Unit must have a single power door.4.Unit must not be recessed through any walls.5.Unit must have programmable cycles and provide both gravity and liquid cycles.6.Unit must be able to program in degrees Celsius.7.Unit must have an automatically-flushing integral steam generator.8.Unit generator must be equipped with a system to prevent scale build up over time in order to extend the life of the unit.9.Unit must have a water saving control system and automatic utilities startup/shutdown.10.Unit must have an optimal solution cooling system in place for liquid cycles, which will be used to sterilize prepared media in bottles and tubes.11.Unit must have a control system that provides an easy-to-read display, continuous cycle monitoring and control, and protects critical components from heat and moisture to avoid recurring and expensive circuit board replacement.12.Unit must have a self-prompting display.13.Unit must have printer with easy spool replacement.14.Unit available accessories must include a rack and two (2) shelves. Additionally, the successful vendor must be able to: de-install the current Steris Amsco Century SG-120 autoclave and remove it from the site; install the new autoclave within thirty (30) days after receipt of order (ARO); and provide, at least, a one (1) year preventative maintenance agreement. *Note - the successful vendor will have ownership of the current autoclave after its de-installation and removal from the site. Given that the current unit has a value, offerors may find it wise to reduce their price quote accordingly. The reason for the current autoclave?s inoperability is unknown. Vendors must meet all characteristics as described above in order to be acceptable for award. Vendors will be evaluated on a lowest-priced, technically acceptable basis. Interested vendors are instructed to submit a price proposal for a brand name or equal item in response to this solicitation no later than the response date. All responses and/or questions should be sent via email to Stefan Martiyan at martiyan.stefan@epa.gov. The deadline for submitting a proposal in response to this solicitation is 4 March 2011, 3:00 PM, ET. Late responses will not be evaluated for award.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/EPA/OAM/HQ/PR-OCSPP-11-00044/listing.html)
 
Place of Performance
Address: Michele Cottrill, MicrobiologistU.S. EPA701 Maples RoadFt. MeadeMD20755-5350USA
Zip Code: 20755-5350
 
Record
SN02383683-W 20110220/110218234219-ad3261b101da4ceb57227fd568267518 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.