Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MARCH 19, 2011 FBO #3402
MODIFICATION

66 -- Process Automation Controller (PAC) Panels

Notice Date
3/17/2011
 
Notice Type
Modification/Amendment
 
NAICS
334519 — Other Measuring and Controlling Device Manufacturing
 
Contracting Office
Department of Commerce, National Institute of Standards and Technology (NIST), Acquisition Management Division, 100 Bureau Drive, Building 301, Room B129, Mail Stop 1640, Gaithersburg, Maryland, 20899-1640
 
ZIP Code
20899-1640
 
Solicitation Number
SB1341-11-RQ-0140
 
Archive Date
4/8/2011
 
Point of Contact
Joshua D. Holliday, Phone: 3019758497, Andrea A Parekh, Phone: (301)975-6984
 
E-Mail Address
joshua.holliday@nist.gov, andrea.parekh@nist.gov
(joshua.holliday@nist.gov, andrea.parekh@nist.gov)
 
Small Business Set-Aside
Total Small Business
 
Description
Amendment to Solicitation SB1341-11-RQ-0140 for Process Automation Controller (PAC) Panels. The above referenced solicitation is hereby amended to respond to technical questions submitted, incorporate technical changes, and extend the due date for quotations. 1.) Technical questions and responses are hereby provided: QUESTION #1: Please confirm no programming is required? RESPONSE #1: No programming is required. QUESTION #2: Were any drawings issued pertinent to this RFQ? RESPONSE #2: No drawings were issued. QUESTION #3: Line Item 0001, Specification #3 states the panels must have a 28" x 18" footprint including 1.5" of clearance space all the way around the panel reserved for mounting. Is the 28" x 18" footprint set in stone? RESPONSE #3: An alternate mounting location will support 36" x 19" per panel. Both 28" x 18" and 36" x 19" are acceptable footprints. QUESTION #4: Please confirm that the panels are backplane only, no enclosure? RESPONSE #4: Backplane only. No enclosure required. QUESTION #5: Line Item 0001, Specifications #9 states analog inputs must be bank isolated with a maximum of four (4) inputs per bank. Specification #10 states analog input modules must have a maximum density of eight (8) inputs per module. There is no OPTO-22 module that has 8 inputs in two (2) isolated banks. There is a module in which all 8 inputs share a reference, but are isolated from the other modules. Alternately, there is a module with 4 inputs per card that share a reference, but are isolated from the other modules. Which card will be acceptable, the 8 input or 4 input? RESPONSE #5: The 8 input module that is isolated from the other modules is acceptable (equivalent to OPTO-22 SNAP-AIV-8). QUESTION #6: Will the OPTO-22 SNAP AIV-8 be acceptable? RESPONSE #6: Yes, the OPTO-22 SNAP AIV-8 is acceptable. QUESTION #7: Are the panels going to be wall-mounted or floor-mounted? If floor mounted, how tall can they be? RESPONSE #7: The panels are to be horizontally mounted. They must not be more than 8" tall off of the backplane. 2.) The following changes are hereby incorporated to the specifications under Line Item 0001. 2.1) Specification #3 changed to read as follows: From: The panels must have a 28" x 18" footprint including 1.5" of clearance space all the way around the panel reserved for mounting. To: The panels must have a 28" x 18" or 36" x 19" footprint including 1.5" of clearance space all the way around the panel reserved for mounting. 2.2) Specification #9 changed to read as follows: From: Analog inputs must be bank isolated with a maximum of four (4) inputs per bank. To: Analog input modules must be isolated from the other input modules by at least 600V. 3.) The due date for quotations is hereby extended: From: 3:00 PM eastern time, on March 18, 2011. To: 3:00 PM eastern time, on March 24, 2011.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DOC/NIST/AcAsD/SB1341-11-RQ-0140/listing.html)
 
Place of Performance
Address: 100 Bureau Drive, Gaithersburg, Maryland, 20899, United States
Zip Code: 20899
 
Record
SN02403692-W 20110319/110317234942-bab53398ecc9c73839d614443153c807 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.