Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MARCH 25, 2011 FBO #3408
SOURCES SOUGHT

58 -- MADO

Notice Date
3/23/2011
 
Notice Type
Sources Sought
 
Contracting Office
CECOM Contracting Center (CECOM-CC), ATTN: AMSEL-AC, Building 1208, Fort Monmouth, NJ 07703-5008
 
ZIP Code
07703-5008
 
Solicitation Number
MARKET-SURVEY-5060-1
 
Response Due
4/4/2011
 
Archive Date
6/3/2011
 
Point of Contact
Harold Schwake, 000-000-0000
 
E-Mail Address
CECOM Contracting Center (CECOM-CC)
(harold.schwake@us.army.mil)
 
Small Business Set-Aside
N/A
 
Description
John Padre 443-395-1281 AND/OR Franklin Lee 732-532-2287 FOR MORE INFORMATION PLEASE CONTACT John Padre, EMAIL john.padre@us.army.mil, Franklin Lee, EMAIL franklin.f.lee@us.army.mil **You must respond NO LATER than the Respond Date and Time The ACC-APG-C4ISR intends to acquire the following in support of the Multi Award Delivery Order (MADO): Group 1 - Aviation and Ground Night Vision Goggle Systems ***The below Image Intensifier Tubes and/or Ground Systems WILL have either GEN II or GEN III Image Intensifier Tubes with a Figure of Merit (FOM) of: Non-NATO Countries, unless otherwise specified, FOM is greater than or equal to 1200 but no greater than 1400 oMinimum Resolution is greater than or equal to 57 lp/mm NATO Countries, unless otherwise specified, FOM is greater than or equal to 1400 but no greater than 1600 oMinimum Resolution greater than or equal to 57 lp/mm Halo must be greater than or equal to 0.85 (GEN III Only) Ground systems and weapon sights must meet spot specs: GEN II Spots for Ground Systems Zones123 >.014000 >.011 -.014 (in.)000 >.009 -.011 (in.)00.03 >.005 -.009 (in.)0.07.07 >.002 -.005 (in.).03.07.07.012 or larger000 >.009 -.012 (in.)001 >. 006 -.009 (in.)022 >. 003 -.006 (in.)023 No emission points Mandatory Requirements for all Ground Systems: 1)All Image Intensifier Tubes must bear some permanent marking sufficient to identify each tube's Manufacturer and each Tube by a unique serial number. 2)Inclusion of a Manufacturer's Data Sheet is MANDATORY for each Image Intensifier Tube, identified by its unique serial number. 3)Must not have a wrap around gated power supply with auto-gating feature. ***The below Image Intensifier Tubes and/or Aviation Systems WILL have either GEN II or GEN III Image Intensifier Tubes with a Figure of Merit (FOM) of: Non-NATO Countries, unless otherwise specified, FOM is greater than or equal to 1200 but no greater than 1400 oMinimum Resolution is greater than or equal to 64 lp/mm NATO Countries, unless otherwise specified, FOM is greater than or equal to 1400 but no greater than 1600 oMinimum Resolution greater than or equal to 64 lp/mm GEN II Spots for Aviation Systems Zones123 greater than.014000 greater than.011 -.014 (in.)000 greater than.009 -.011 (in.)000 greater than.005 -.009 (in.)0.03.03 greater than.002 -.005 (in.).03.07.07 less than.002MinMinMin GEN III Spots for Aviation Systems Zones123 greater than.012 or larger000 greater than.009 -.012 (in.)000 greater than. 006 -.009 (in.)011 greater than. 003 -.006 (in.)022 Mandatory Requirements for all Aviation Systems: 1)All Image Intensifier Tubes must bear some permanent marking sufficient to identify each tube's Manufacturer and each Tube by a unique serial number. 2)Inclusion of a Manufacturer's Data Sheet is MANDATORY for each Image Intensifier Tube, identified by its unique serial number. 3)Must not have a wrap around gated power supply with auto-gating feature. Non-standard commercial export AVS-6/9 Aviator Night Vision Goggle System or equivalent. Each AVS-6/9 shall include one (1) each of the following: Hard or Soft Carrying Case, Lens Caps, Lens Paper, Neck Cord, Low-Profile Battery Pack and Suitable Mounting Kit, Operator Manual, Helmet Modification Instructions, Helmet Mount Salient Characteristics: EMI/EMC Shielded System per MIL-STD 461 Magnification: Unity Field of View: 40 nominal +-2 degrees Resolution: 1.3 cy/mr, minimum for 64 lp/mm System Brightness Gain: 5500 fl/fl minimum Collimation: less than=1 convergence less than =0.3 dipvergence/divergence Interpupillary Adjustment: Independent, 51 to 72mm total Vertical Adjustment: 25 mm Fore and Aft Adjustment: 27 mm Tilt Adjustment: 10 Objective Lens Focus: Range 41 cm to infinity Eyepiece Lens: EFL 23-27mm Eyepiece Exit Pupil/Eye Relief: On-axis: 14 mm @ 25 mm distance Full-field: 6 mm @ 25 mm distance Eye Piece Adjustment: +2 to -6 diopters Flip-up/Flip-down: Button release Automatic Breakaway: 11 to 15 g Battery Type: Commercially available 4 each AA (1.5 V) size OR CR123 (3 V DC) Weight of AVS-9 (maximum): 590 grams (without mount) Operating Temperature: -30 C to +50 C System Test Data Sheet: Yes Warranty (minimum): 1 year GEN II Spots for Aviation Systems Zones123 greater than.014000 greater than.011 -.014 (in.)000 greater than.009 -.011 (in.)000 greater than.005 -.009 (in.)0.03.03 greater than.002 -.005 (in.).03.07.07 less than.002MinMinMin GEN III Spots for Aviation Systems Zones123 greater than.012 or larger000 greater than.009 -.012 (in.)000 greater than. 006 -.009 (in.)011 greater than. 003 -.006 (in.)022 Non-standard commercial export PVS-7B/D Night Vision Goggle System or equivalent. Each PVS-7B/D shall include one (1) each of the following: PVS-7B/D compatible Head Mount Assembly with one set of brow pads (if required), Sacrificial Window, Carrying Case, (2) Demist Shields, Lens Paper, Lens Cap, (2) Soft Eye Cup, Shoulder Strap, Neck Cord, Operator Manual, (2) commercially available batteries. Salient characteristics: Field of View: 40 ( 2 ) Magnification: Unity Resolution: 1.0 cy/mr, minimum System Brightness Gain: 3000 fL/fL, minimum Collimation: 1 1 in the horizontal plane less than or equal to 1/2 dipvergence Diopter Adjustment: +2 to -6 diopters Interpupillary Adjustment: 55 to 71 mm Eye Relief: 15 mm Objective Lens: 25-27mm, F/1.2, T/1.3 Eyepiece Lens: EFL 25-27 mm Focus Range: 25 cm to infinity Weight of the PVS-7B/D: 680 grams maximum Operating Temperature Range: -30 C to +49 C Storage Temperature Range: -50 C to +70 C Battery Type: Commercially available batteries Immersion: 1 meter at 30 minutes System Test Data Sheet: Yes Warranty (minimum): 1 year Non-standard commercial export PVS-14 with Manual Variable Gain Night Vision Goggle System or equivalent. Each PVS-14 shall include one (1) each of the following: Small Arms Adapter (MIL-STD 1913), Shuttered Eye Guard, PVS-14 Compatible Head Mount Assembly, Medium and Thick Brow Pads, Eye Cup, Operator Manual, Demist Shield Assembly, Sacrificial Window Assembly, Soft Carrying Case, Shoulder Strap, Lens Paper, Head Mount Adapter. Salient Characteristics: Magnification: Unity Range Focus: 25 cm to infinity Diopter Adjustment: +2 to -6 diopters Eye Relief: 25 mm (1 in) Field of View: 40 ( 2 ) System Brightness Gain: Adjustable from 25 to more than 3,000 Operating Temperature: -30 C to +49 C Storage Temperature: -50 C to +70 C Weight of PVS-14 w/o Batteries (maximum): 400 grams Battery Type: commercially available Batteries Immersion: 1 meter at 30 minutes System Test Data Sheet: Yes Warranty (minimum): 1 year Non-standard commercial export Mini Monocular Night Vision Goggle. Each Mini Monocular shall include one (1) each of the following: Head Mount Assembly, Weapons Mount, Small, Medium and Large Brow Pads, Head Mount Adapter, Eye Cup, Soft Carrying Case, Lens Paper, Sacrificial Window, and Demist Shield. Salient Characteristics: Magnification: Unity Range Focus: 25 cm to infinity Diopter Adjustment: +2 to -6 diopters Eye Relief: 25 mm (1 in) Field of View: 40 ( 2 ) Operating Temperature: -30 C to +49 C Storage Temperature: -50 C to +70 C Power Source: commercially available batteries Weight w/Batteries: 370 Grams IR Illuminator: Yes (Built-in) Immersion: 1 meter at 30 minutes System Test Data Sheet: Yes Warranty (minimum): 1 year GROUP 2 - Ground Night Vision Sights/Scopes Non-standard commercial export PVS-10 Day/Night Sniper Sight or equivalent. Each PVS-10 Day/Night Sniper Sight shall include one (1) each of the following: Eyepiece Bumper, AA Batteries, Lens Paper, Sun Shade, Tool Kit, Technical Bulletin/Operation Manual, Soft Carrying Case. Salient Characteristics: Integrated day/night operation Manual gain control Adjustable, illuminated reticle Low profile for balance and signature reduction Field of View (FoV): 2.0 Focal Length: 125 mm (4.9 in) Minimum Focus Distance: 25 m (27.3 yd) Magnification: 8.5X Detection Range: 600 m night/ 800 m day (656.2 yd night/ 874.9 yd day) Diopter: +2 to -5 Eye Relief: 76 mm (3 in) Power Source: 2 AA Batteries Battery Life: 24(+) hours @ room temperature Color: Black Length: 34.2 cm (16.1 in) Width: 10.4 cm (4.1 in) Height: 11.7 cm (4.6 in) Weight: 2.2 Kg with batteries (4.9 lbs) Mount: Mount for Picatinny Rail (MIL-STD-1913) Standard (Optional Mounts & Tool Kits Available for Multiple Weapons System Test Data Sheet: Yes Warranty (minimum): 1 year Non-standard commercial export PVS-26 Universal Night Sight-Long Range or equivalent. Each PVS-26 UNS-LR System shall include the following: Shroud Wrap, Lens Cover, Base Adjustment Wrenches, Lens Cleaning Kit, 1913 mounting capabilities, AA Battery, Hard Carrying Case, Technical Manual. Salient Characteristics: Size: 3.0" OD x 9.5 long Weight: 3.0 lbs Power: Commercially available batteries Mount: Quick Attach/Detach to Mil-STD-1913 Rail Field of View: 9 Immersion: 1 meter at 30 minutes Bore Sight: Factory Bore Sight to within.5 MOA of alignment to the day scope point of impact Boresight Retention: <.5 MOA over 300 rounds, 300 WIN MAG firing schedule Tested for use on weapons up to and including.50 caliber rifles 120MM Refractive Telephoto Lens Design Magnification: Unity Focus Range: 20 meters to infinity Warranty (minimum): 1 year GROUP 3 - Thermal Imaging Devices Non-standard commercial export Light Thermal Weapon Sight. Each LTWS shall include one (1) each of the following: hard-side carrying case, soft-side carrying case, operator manual, quick reference guide, batteries, and lens cleaning kit. Salient Characteristics: Detector: Uncooled Microbolometer Spectral Response: 8-12 m Pixel Pitch: 25 m or higher Pixel Count (Resolution): 320 X 240 Horizontal Field of View (HFOV) - Wide: 12 -24 2x e-zoom (minimum) Standard Mount: MIL-STD-1913 Picatinny Rail Reticles: Adjustable to Boresight Weight with Batteries: 3.3 lbs (maximum) Operating Temperature: -30 C to +50 C Storage Temperature: -40 C to +70 C Source: Commercially available Batteries Operating Time: 5 Hours at room temperature (minimum) Frame Rate: 30 Hz (minimum) Display Resolution: 640 x 480 (minimum) Diopter Adjustment: +2 to -6 diopters Non-standard commercial export Medium Thermal Weapon Sight. Each MTWS shall include one (1) each of the following: hard-side carrying case, soft-side carrying case, operator manual, quick reference guide, batteries, and lens cleaning kit. Salient Characteristics: For NATO+ countries: 640 x 480 Uncooled Microbolometer Pixel Count (Resolution): 640 X 480, 25 micron pitch Horizontal Field of View (HFOV) - Wide: 14 -20 For all eligible countries Detector: Uncooled Microbolometer Spectral Response: 8-12 m Pixel Pitch: 25 m or higher Pixel Count (Resolution): 320x240 Uncooled Microbolometer, 25 micron pitch Horizontal Field of View (HFOV) - Wide: 8 -15 2x e-zoom (minimum) Standard Mount: MIL-STD-1913 Picatinny Rail Reticles: Adjustable to Boresight Weight with Batteries: 3.3 lbs (maximum) Operating Temperature: -30 C to +50 C Storage Temperature: -40 C to +70 C Source: Commercially available Batteries Operating Time: 5 Hours at room temperature (minimum) Frame Rate: 30 Hz (minimum) Display Resolution: 640 x 480 (minimum) Diopter Adjustment: +2 to -6 diopters Non-standard commercial export Heavy Thermal Weapon Sight. Each HTWS shall include one (1) each of the following: hard-side carrying case, soft-side carrying case, operator manual, quick reference guide, batteries, and lens cleaning kit. Salient Characteristics: For NATO+ countries: 640 x 480 Uncooled Microbolometer Pixel Count (Resolution): 640 X 480, 25 micron pitch Horizontal Field of View (HFOV) - Wide: 8 -12 For all eligible countries Detector: Uncooled VOx Microbolometer Spectral Response: 8-12 m Pixel Pitch: 25 m or higher Pixel Count (Resolution): 320 X 240 Horizontal Field of View (HFOV) - Wide: 4-8 2x e-zoom (minimum) Standard Mount: MIL-STD-1913 Picatinny Rail Reticles: Adjustable to Boresight Weight w/ Batteries: 4.0 lbs (maximum) Operating Temperature: -30 C to +50 C Storage Temperature: -40 C to +70 C Source: Commercially available Batteries Operating Time: 5 Hours at room temperature (minimum) Frame Rate: 30 Hz (minimum) Display Resolution: 640 x 480 (minimum) Diopter Adjustment: +2 to -6 diopters Non-standard commercial export Clip-On Night Vision Device - Thermal Sight. Each CNVD-TS shall include the following: soft carrying case, operator manual, quick reference guide, lens cleaning kit, hooded aperture, eyecup assembly, commercially available batteries. Salient Characteristics: Weight: 2 lbs w/Batteries (maximum) Multi-use: Hand-held or weapons mounted Unity Magnification Start-up time under 5 seconds at room temperature 2X digital zoom Boresight Adjustable Focus Range: 3 Meters to Infinity ( ) Mounts to any MIL-STD-1913 Picatinny Rail Polarity and calibration Reticle On/Off: Reticle adjustment Immersion to 1 meter for 30 minutes Operating Time: 5 Hours at room temperature (minimum) Boresight retention (1 minute of angle relative to the daysight) Group 4 - Image Intensifier Tubes and Test Equipments Non-standard commercial export MX-10130 GEN III Image Intensifier Tubes for the PVS-7B/D Night Vision Goggle Salient Characteristics: Resolution: 57 lp/mm (minimum) High-Light Resolution @ 20 fc (minimum): 12 Photocathode Sensitivity @1400 FOM = 1350 A/lm @830 nm = 135 and @ 880 nm = 65 @1600 FOM = 1500 A/lm @830 nm = 155 and @880 nm = 77 Halo, mm (minimum): 0.85 EBI, X10^-11 lm/cm^2 (Maximum) 2.5 Luminous Gain, fL/fc @2X10^-6 fc: 40000 - 70000 @2X10^-4 fc: 10000 - 20000 Output Brightness, fL@1 and 20 Fc: 2.0-4.0 Output Brightness, Uniformity (Maximum) @2856 K and @880 nm: 3.1 MTF (Minimum) @2.5 lp/mm: 92% @7.5 lp/mm: 80% @15.0 lp/mm: 61% @25.0 lp/mm: 38% Photocathode Diameter, mm (Minimum): 17.5 Phosphor: P-43 Maximum Spots Allowed in Each Zone (for Ground Systems): greater than.012 or larger000 greater than.009 -.012 (in.)001 greater than. 006 -.009 (in.)022 greater than. 003 -.006 (in.)023 No emission points Warranty (minimum): 1 year Non-standard commercial export MX-10160 GEN III Image Intensifier Tubes for the AVS-6/9 Aviator Night Vision Goggle Salient Characteristics: Resolution: 64 lp/mm (for Aviation Systems) Resolution: 57 lp/mm (for Ground Systems) High-Light Resolution @ 20 fc (minimum): 12 Photocathode Sensitivity (Minimum) @1400 FOM = 1350 A/lm @830 nm = 135 and @ 880 nm = 65 @1600 FOM = 1500 A/lm @830 nm = 190 and @880 nm = 80 Halo, mm (minimum): 0.85 EBI, X10^-11 lm/cm^2 (Maximum) 2.5 Luminous Gain, fL/fc @2X10^-6 fc: 40000 - 70000 @2X10^-4 fc: 10000 - 20000 Output Brightness, fL@1 and 20 Fc: 2.0 - 4.0 Output Brightness, Uniformity (Maximum) @2856 K and @880 nm: 3.1 MTF (Minimum) @2.5 lp/mm: 92% @7.5 lp/mm: 80% @15.0 lp/mm: 61% @25.0 lp/mm: 38% Maximum Spots Allowed in Each Zone (for Ground Systems): Zones123 greater than.012 or larger000 greater than.009 -.012 (in.)001 greater than. 006 -.009 (in.)022 greater than. 003 -.006 (in.)023 No emission points Maximum Spots Allowed in Each Zone (for Aviation Systems): Zone Spot Size (in.): 123 greater than.012 or Larger: 000 greater than.009 -.012 (in.)0 00 greater than.006 -.009 (in.)011 greater than.003 -.006 (in.)022 Warranty (minimum): 1 year Non-standard commercial export MX-11769 GEN III Image Intensifier Tubes for the PVS-14 Night Vision Monocular Salient Characteristics: Resolution: 57 lp/mm (minimum) High-Light Resolution @ 20 fc (minimum): 12 Photocathode Sensitivity (Minimum) @2856 : K, A/lm: 1500 @830 nm, mA/W: 155 Halo, mm (minimum): 0.85 EBI, X10^-11 lm/cm^2 (Maximum) 2.5 Luminous Gain, fL/fc @2X10^-6 fc: 40000 - 70000 @2X10^-4 fc: 10000 - 20000 Output Brightness, fL@1 and 20 Fc: 2.0 - 4.0 Output Brightness, Uniformity (Maximum) @1400 FOM = 1350 A/lm @830 nm = 135 and @ 880 nm = 65 @1600 FOM = 1500 A/lm @830 nm = 155 and @880 nm = 77 MTF (Minimum) @2.5 lp/mm: 92% @7.5 lp/mm: 80% @15.0 lp/mm: 61% @25.0 lp/mm: 38% Photocathode Diameter, mm (Minimum): 17.5 Phosphor: P-43 Maximum Spots Allowed in Each Zone (for Ground Systems): Zones123 greater than.012 or larger000 greater than.009 -.012 (in.)001 greater than. 006 -.009 (in.)022 greater than. 003 -.006 (in.)023 No emission points Warranty (minimum): 1 year Non-standard commercial export GEN II Image Intensifier Tubes for the AVS-6/9 Aviator Night Vision Goggle Salient Characteristics:UnitsMinMax Gain at 2.10^-5 lxcd/m^2/lx900015000 Gain at 2.10^-6 fcfl/fc2825047100 Maximum Output Brightnesscd/m^248 Maximum Output Brightnessfl1.22.3 M.T.F. at 2.5lp/mm9292 at 7.5lp/mm8080 at 15 lp/mm5858 at 25 lp/mm4545 at 30lp/mm3535 E.B.I. lx0.30 Burn-inhours50 Image Inversiondegrees179181 Shear Distortion m50 Gross Distortion m75 Useful Cathode Diametermm17.5 Bright Source Protectionseconds60 Fixed Pattern Noise at 2 mlx%-10+10 Image Alignmentmm0.3 Massgrams85 GEN II Spots for Aviation Systems Zones123 greater than.014000 greater than.011 -.014 (in.)000 greater than.009 -.011 (in.)000 greater than.005 -.009 (in.)0.03.03 greater than.002 -.005 (in.).03.07.07 less than.002MinMinMin Non-standard commercial export GEN II Image Intensifier Tubes for the PVS-7B/D Night Vision Goggle Salient Characteristics:UnitsMinMax Gain at 2.10^-5 lxcd/m^2/lx900015000 Gain at 2.10^-6 fcfl/fc2825047100 Maximum Output Brightnesscd/m^248 Maximum Output Brightnessfl1.22.3 M.T.F. at 2.5lp/mm9292 at 7.5lp/mm8080 at 15 lp/mm5858 at 25 lp/mm4545 at 30lp/mm3535 Burn-inhours50 Shear Distortion m60 Gross Distortion m75 Useful Cathode Diametermm17.0 Massgrams95 GEN II Spots for Ground Systems Zones123 greater than.014000 greater than.011 -.014 (in.)000 greater than.009 -.011 (in.)000.3 greater than.005 -.009 (in.)0.07.07 greater than.002 -.005 (in.).07.07.11 less than.002MinMinMin Non-standard commercial export GEN II Image Intensifier Tubes for the PVS-14 Night Vision Monocular (including support for Manual Gain) Salient Characteristics:UnitsMinMax Gain at 2.10^-5 lxcd/m^2/lx900015000 Gain at 2.10^-6 fcfl/fc2825047100 Maximum Output Brightnesscd/m^248 Maximum Output Brightnessfl1.22.3 M.T.F. at 2.5lp/mm9292 at 7.5lp/mm8080 at 15 lp/mm5858 at 25 lp/mm4545 at 30lp/mm3535 Burn-inhours50 Image Inversiondegrees178182 Shear Distortion m60 Gross Distortion m75 Useful Cathode Diametermm17.0 Image Alignmentmm0.5 Massgrams85 GEN II Spots for Ground Systems Zones123 greater than.014000 greater than.011 -.014 (in.)000 greater than.009 -.011 (in.)000.3 greater than.005 -.009 (in.)0.07.07 greater than.002 -.005 (in.).07.07.11 less than.002MinMinMin TS-4348/UV Night Vision Device Assessor ANV-20/20 Night Vision Device Infinity Focus System ANV-126A-001 Night Vision Device Assessor ANV-126A-006 Night Vision Device Assessor Respond to My Attention by COB on Tuesday, 5 April 2011 john.padre@us.army.mil, franklin.f.lee@us.army.mil Army Contracting Command-Aberdeen Proving Ground-C4ISR N/A Army Contracting Command-Aberdeen Proving Ground-C4ISR 21005
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/notices/d4afa7346157daa03bd0d6f4c2977d71)
 
Place of Performance
Address: CECOM Contracting Center (CECOM-CC) ATTN: AMSEL-AC, Building 1208 Fort Monmouth NJ
Zip Code: 07703-5008
 
Record
SN02407954-W 20110325/110323234853-d4afa7346157daa03bd0d6f4c2977d71 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.