Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MARCH 27, 2011 FBO #3410
SOLICITATION NOTICE

J -- Full Service Maintenance for MRI Equipment

Notice Date
3/25/2011
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
334510 — Electromedical and Electrotherapeutic Apparatus Manufacturing
 
Contracting Office
N00259 NAVAL MEDICAL CENTER SAN DIEGO MATERIAL MANAGEMENT 34800 Bob Wilson Drive San Diego, CA
 
ZIP Code
00000
 
Solicitation Number
N0025911T0221
 
Response Due
3/31/2011
 
Archive Date
4/30/2011
 
Point of Contact
Reynaldo de Vera 619-532-5564
 
Small Business Set-Aside
N/A
 
Description
The proposed contract action is for commercial item, which the Naval Medical Center San Diego intends to solicit this requirement on a sole source basis to INVIVO CORP. under the authority of Far 13.106-1 (b). This is a combined solicitation/synopsis for commercial items, prepared in accordance with the format in FAR subpart 12.6 as supplemented with additional information included in this notice. This announcement constitutes only solicitation, quotations are being requested and a written solicitation will not be issued. The solicitation number, N00259-11-T-0221 is issued as a request for quotation (RFQ). The North American Industry Classification System (NAICS) Code for this acquisition is 334510. All interested bidders shall submit quotations electronically by email to reynaldo.devera@med.navy.mil or by facsimile at 619-532-5596, attention Reynaldo de Vera E-mail submissions are limited to 2MB. The submitter should confirm receipt of facsimile and email submissions. Quotations are due on or before 31 March 2011, 1:00PM Pacific Standard Time to be considered responsive. CLIN 0001 MRI Equipment Full Service Maintenance to include parts, labor, transportation, remote applications and tech support in accordance with the Statement of Work. Period of Performance: 01 April 2011 through 30 September 2011 CLIN 0001AA DynaSuite Serial #: 790353GE, ECN: 103093 QTY 2 Qrts $_______per Quarter CLIN 0001AB Esys Serial #: 14GE, ECN: 103105 QTY 2 Qrts $_______per Quarter CLIN 0001AC Esys Serial #: 790348 SMS, ECN: 103094 QTY 2 Qrts $_______per Quarter CLIN 0001AD Esys Serial #: 21SMS, ECN: 103104 QTY 2 Qrts $_______per Quarter CLIN 0002 Option Year MRI Equipment Full Service Maintenance to include parts, labor, transportation, remote applications and tech support in accordance with the Statement of Work. Period of Performance: 01 Octoberl 2011 through 30 September 2012 CLIN 0002AA DynaSuite Serial #: 790353GE, ECN: 103093 QTY 4 Qrts $_______per Quarter CLIN 0002AB Esys Serial #: 14GE, ECN: 103105 QTY 4 Qrts $_______per Quarter CLIN 0002AC Esys Serial #: 790348 SMS, ECN: 103094 QTY 4 Qrts $_______per Quarter CLIN 0002AD Esys Serial #: 21SMS, ECN: 103104 QTY 4 Qrts $_______per Quarter Under the authority of FAR 13.106-1(b), sole source justification is based on INVIVO CORP. software and hardware parts are proprietary that can only be serviced by OEM. Contractor must be registered to the Central Contractor Registration (CCR) prior to award. The website address for CCR registration is www.ccr.gov Contractor MUST complete FAR 52.212-3, Offeror Representations and Certifications “ Commercial Items, when submitting a proposal. The website address is http://www.acquisition.gov. DELIVERY ADDRESS: Naval Medical Center San Diego, 34800 Bob Wilson Drive, San Diego, CA. 92134 The solicitation document and incorporated provisions and clauses are those in effect through FAC 2005-50 and DFARS Change Notice 20110304. This acquisition incorporates the following FAR clauses: 52.204-7 Central Contractor Registration (APR 2008) 52.212-1 Instruction to Offerors-Commercial Item (JUN 2008) 52.212-3 Offeror Representations and Certification--Commercial Items (JAN 2011) 52.212-4 Contract Terms and Conditions--Commercial Items (JUN 2010) 52.212-5 Contract Terms and Conditions Required to Implement Statutes or Executive Orders--Commercial Items (JAN 2011) 52.217-5 Evaluation Of Options (JUL 1990) 52.217-8 Option To Estend Services (NOV 1999) 52.217-9 Option To Extend The Term Of The Contract (MAR 2000) 52.219-28 Post Award Small Business Program Representative (APR 2009) 52.222-3 Convict Labor (JUN 2003) 52.222-19 Child Labor -- Cooperation with Authorities and Remedies (JUL 2010) 52.222-21 Prohibition Of Segregated Facilities (FEB 1999) 52.222-26 Equal Opportunity (MAR 2007) 52.222.36 Affirmative Action for Workers with Disabilities (OCT 2010 52.222-48 Exemption from Application of the Service Contract Act to Contacts for Maintenance, Calibration, or Repair of Certain Equipment Certification (FEB 2009) 52.222-51 Exemption from Application of the Service Contract Act to Contracts for Maintenance, Calibration, or Repair of Certain Equipment-Requirements (NOV 2007) 52.223-7 Notice Of Radioactive Materials (JAN 1997) 52.223-18 Contractor Policy to Ban Text Messaging while Driving (SEP 2010) 52.225-13 Restrictions on Certain Foreign Purchases (JUN 2008) 52.232-33 Payment by Electronic Funds Transfer-Central Contractor Registration (OCT 2003) 52.237-3 Continuity Of Services (JAN 1991) 52.252-2 Clauses Incorporated By Reference (FEB 1998) 252.204-7003 Control Of Government Personnel Work Product (APR1992) 252.204-7004 Alt A Central Contractor Registration (52.204-7) Alt A (SEP 2007) 252.212-7001 Contract Terms and Conditions Required to Implement Statutes or Executive Orders Applicable to Defense Acquisitions of Commercial Items (APR 2007) 252.225-7001 Buy American Act and Balance of Payment Program (JAN 2009) 252.225-7002 Qualifying Country Sources As Subcontractors (APR 2003) 252.232-7003 Electronic Submission of Payment Requests (MAR 2008) All responsible sources may submit a quotation which shall be considered by the agency. STATEMENT OF WORK MEDICAL EQUIPMENT SERVICE MAINTENANCE WITH NO LOANER OPTION GENERAL REQUIREMENTS: The effort required hereunder shall be performed in accordance with this Statement of Work and in accordance with all other terms and conditions set forth herein. CONTRACTOR shall provide all services, materials and equipment necessary for the repair/preventive maintenance of x-ray equipment mention with ECN: 103094, 103105, 103095, 103104 located in the Radiology Department Naval Medical Center, San Diego (NMCSD)to ensure dependable and reliable equipment operation. The scope of work performed under these specifications includes the furnishing of all labor, and parts to perform all repairs on equipment listed, to assure continued operation at their designed efficiency and capacity. śRepair ť means any (a) modification, adjustment, or replacement of the hardware that corrects a malfunction by bringing the hardware into material conformity with the technical specifications for the hardware or (b) a procedure or routine that, when observed in the regular operation of the hardware, avoids the material adverse effect of the applicable nonconformity. NMCSD PREVENTIVE MAINTENANCE REQUIREMENTS: Perform service repair/preventive maintenance to industry standards. Ensure that only FULLY QUALIFIED FIELD ENGINEERS and TECHNICIANS who have gone through original equipment manufacturer (OEM) or comparable third party service schools for the above-mentioned equipment, shall be employed in the performance of any and all work performed under this contract. Upon request, CONTRACTOR Medical System shall provide training certificates (or notarized copies) to the Medical Repair Branch for verification. The highest standard of professional capability and electrical/mechanica1 workmanship is to be maintained throughout the life of this contract. Make repairs to the extent necessary (as determined by inspection tests or disassembly) to ensure a functional system that will efficiently serve its intended purpose. Installation of system update changes to resolve specific product reliability problems. Hardware and software upgrades, defined as those changes that enhance or add product features, are not included. CONTRACTOR shall perform all scheduled preventive maintenance as agreed upon during initial Contact with the Contract Administrator. NMCSD REPAIR REQUIREMENTS: NMCSD Biomedical Engineering will provide the initial assessment. Provide only the work necessary to restore the equipment to a serviceable/operating condition by adjustments, replacement parts, or minor repairs when it is determined that extensive repairs and parts replacements are not necessary. Equipment improvements/modifications shall be made only upon Medical Repair Branch written approval and direction. Notify the Medical Repair Branch immediately upon receipt of OEM or Replacement parts/equipment safety recalls notices. Insure that original design and functional capabilities will not be changed, modified, or altered unless the Medical Repair Branch authorizes such changes. Provide suitable OEM recommended repair equipment/tools required for the satisfactory execution of all repairs made. Furnish manufacturer OEM approved lubricants and lubricate wear points within the equipment. Extend to the Government all commercial warranties on replacement parts, consistent with standard industry practices. TRAVEL AND RELATED EXPENSES: CONTRACTOR shall be responsible for its service related trip expenses including round trip travel, mileage, and overnight living expenses. RESPONSE TIME: CONTRACTOR shall use commercially reasonable efforts to: Respond by telephone to any report of a malfunction requiring repair within one hour of notification by NMCSD, Monday “ Friday 0800-1700. Provide on-site support within 1 business day of notification by NMCSD personnel. TITLE TO EQUIPMENT: CONTRACTOR shall not assume possession or control of any part of the equipment. The Government retains ownership to title thereof. LIABILITY: CONTRACTOR shall not be liable for any loss, damage, or delay due to any cause beyond his reasonable control including but not limited to, acts of government, strikes, lockouts, fire, explosion, theft, floods, riot, civil commotion, war, malicious mischief or acts of God. UTILITIES: CONTRACTOR may use Government utilities, (e.g., electrical power, compressed air, and water) which are available and required for any service performed under this contract. The building engineer, to ensure compatibility with the Naval Medical Center's electrical wiring and equipment, must approve contractor electrical equipment. ACCESS TO EQUIPMENT: CONTRACTOR shall be provided reasonable access to all equipment that is to be serviced and utility outlets required to do the service. The contractor shall be free to start and stop all primary equipment incidentals to the operation of the maintained equipment after permission is received from on duty personnel responsible for such equipment. GOVERNMENT PERSONNEL: NMCSD employees will not perform maintenance or attempt repairs to equipment while such equipment is under the purview of this contract unless agreed to in writing by the contractor. PARTS AVAILABILITY: To ensure minimal equipment downtime, CONTRACTOR shall maintain replacement repair parts and materials necessary to perform each repair or supply said parts and Materials within 1 business day. LABOR: All compensation for labor (0800 through 1700 Local PST Time) is included in the contract price. Any labor performed outside of this timeframe is not included in the contract pricing. If services becomes necessary to be performed beyond 1700, NMCSD Biomedical Repair Division shall be notified prior to performance. Parts and materials: All compensation for parts and materials is included in contract price. PARTS/SUPPLIES QUALITY: Parts and Supplies provided under this contract shall be new. SECURITY REQUIREMENTS: Contractor will be required to contact the Medical Repair Branch at (619) 532-8010 to submit the required information to complete the NMCSD Security Pass Form by 1400 the day prior to the scheduled visit. In the case of emergent repairs/service, the contractor will wait at the main gate for an escort from Medical Repair Branch personnel. CONTRACTOR CHECK-IN/CHECK-OUT: CONTRACTOR is required to report to the Medical Repair Branch for Visitor Badges during the hours of 0800 - 1700, Monday through Friday, prior to and upon completion of any service/repair performed. FIELD SERVICE REPORTS: Contractor shall furnish a written or electronic vendor supplied Field Service Report (FSR) to the Duty Staff at: Naval Medical Center, San Diego Bio Medical Repair Building 1, Ground Floor, Room GD-18H1 Phone: 619-532-8010 Fax: 619-532-8013 Or electronically at: ca@med.navy.mil The contractor, or his representative, shall complete the vendor supplied Field Service Report to include the following: Contractor Name Technician's Printed Name, Telephone Number and Signature Date and Time of Arrival ECN (Equipment Code Number) and Serial Number Time Expended Repairing/Service; Labor Hours, Rate and Materials Summary of Work Performed and Accepted by End-User (Government Representative's Printed Name and Signature) All Field Service Reports shall be submitted within 72 hours of completion of service. COMPLETED FIELD SERVICE REPORTS ARE REQUIRED PRIOR TO ACCEPTANCE OF ANY INVOICE PREVENTIVE MAINTENANCE AND REPAIR SERVICES SCHEDULES SERVICES SHALL BE REQUIRED BASED UPON THE FOLLOWING AGREED SCHEDULES: PREVENTIVE MAINTENANCE: (Check One) __ X___One (1) time per fiscal yearSeptember __ ___Two (2) times per fiscal year __________ ________ __ ___Four (4) times per fiscal year_____/_____/_____/_____ REPAIR: (Check One) __X ___Monday - Friday, 0800-1700 hrs. ___Seven (7) days per week, 24-hour coverage CONTRACTOR POINT OF CONTACT (POC): __________________________________________ (Contractor/Dispatcher/Customer Service) Telephone Number: __________________________FAX : _____________________ E-Mail: ______________________________________
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/BUMED/N00259/N0025911T0221/listing.html)
 
Record
SN02409350-W 20110327/110325234355-ad2c574866c39c5a974478cee467c623 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.