SOLICITATION NOTICE
66 -- Probe Station
- Notice Date
- 3/25/2011
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 334515
— Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals
- Contracting Office
- Department of the Air Force, Air Force Materiel Command, 88 CONS/PK, 1940 ALLBROOK DRIVE, WRIGHT-PATTERSON AFB, Ohio, 45433-5309, United States
- ZIP Code
- 45433-5309
- Solicitation Number
- FA8601-11-P-0220
- Archive Date
- 4/30/2011
- Point of Contact
- Jennifer R. Begg, Phone: 9375222277
- E-Mail Address
-
Jennifer.Begg@wpafb.af.mil
(Jennifer.Begg@wpafb.af.mil)
- Small Business Set-Aside
- N/A
- Description
- The United States Air Force, ASC/Operational Contracting Division, Wright-Patterson AFB, Ohio 45433-5344 is procuring a firm-fixed price contract for providing a probe station to integrate a power device analyzer and curve tracer to be used for wafer measurements. We intend to award this contract sole source under the authority of FAR 6.302-1, Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements. All responsible sources may submit a proposal, by 30 March 2011 at 12:00 PM EST, which shall be considered. The proposed sole source is: Cascade Microtech, 2430 N.W. 206th Ave., Beaverton, OR 97006. The required specifications for the Probe Station are as follows: a. Must have a high voltage probe that connects to Agilent's HVTriax bulkhead Jack-Jack adapter and have the following specifications: able to sustain a maximum voltage of + 3000V DC and a maximum current of 8mA. b. Must hace high voltage probe or probes that connects to Agilent's HPSMU Protection Adapter with the following specifications: able to sustain a maximum voltage of + 2000 DC and a maximum current 1A. c. Must have high voltage probes that connect to Agilent's High Voltage Bias Tee with the following specifications: able to sustain a maximum voltage of + 3000V DC and a maximum current of 8mA. d. Must have high voltage probes that connect to Agilent's GNDU Protection adapter with following specifications: able to sustain a maximum voltage of + 3000V DC and a maximum current of 8mA. e. Must have high current probes that connect to Agilent's Kelvin Adapter for HCSMU adapter with the following specifications: able to sustain a maximum voltage of + DC and a maximum current of 30A pulsed. f. Must be able to satisfy the interlocks on the B1505a for high voltage and high current and to provide the appropriated safety measures needed to operate the test station. Delivery for the equipment shall be 12-15 weeks after receipt of order (ARO). FOB Destination. Payment Terms: Net 30 Days At this time no small business set-aside is expected. NAICS Code 334515, Size Standard 500 employees. Refer all questions and proposals concerning this combined synopsis/solicitation to Jennifer Begg, Contract Specialist, at jennifer.begg@wpafb.af.mil. The Department of Defense (DoD) has determined the Central Contractor Registration (CCR) to be the single DoD registration for contractors who conduct business or who are interested in conducting business with the DoD. Contractors must be registered in CCR prior to award for solicitations issued after 21 May 1998. You may contact CCR at 1-888-CCR-2423, fax at 1-703-696-0213. DUNS/CCR website: http://ccr.edi.disa.mil/ccr/cgi-bin/query.pl.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AFMC/88 CONS/FA8601-11-P-0220/listing.html)
- Record
- SN02409417-W 20110327/110325234439-336f52f1877aef7038fcf378f1175d63 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |