Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF APRIL 01, 2011 FBO #3415
MODIFICATION

34 -- Heat Treat Ovens and Furnaces

Notice Date
3/30/2011
 
Notice Type
Modification/Amendment
 
NAICS
333994 — Industrial Process Furnace and Oven Manufacturing
 
Contracting Office
Department of the Air Force, Air Force Materiel Command, Hill AFB OO-ALC, OO-ALC/PKXB, 6038 Aspen Ave (Bldg 1289), Hill AFB, Utah, 84056
 
ZIP Code
84056
 
Solicitation Number
FA8224-11-T-0011-0001
 
Archive Date
4/1/2011
 
Point of Contact
Mike Garner, Phone: 801-586-8610
 
E-Mail Address
michael.garner@hill.af.mil
(michael.garner@hill.af.mil)
 
Small Business Set-Aside
N/A
 
Description
Question 1: The new (24 Feb 11) Purchase Description/Specifications for the three ovens in this Solicitation do not address interior wall construction. Does the Air Force still want Stainless Steel interior panels as specified earlier? In the 500 deg. oven this would be optional with aluminized steel panels as standard. In the 1,050 deg. and 1,250 deg. ovens, stainless steel panels are a must. Answer: All interior walls shall be constructed using any 300 series stainless steel. Question 2: The new (24 Feb 11) Purchase Description/Specifications for the three ovens in this Solicitation states that installation and testing will be accomplished by the Air Force, and that a factory rep may be present. We will requote this Solicitation with separate pricing for our installation supervisor to be on hand during the tests. Will the government accomplish these tests in one (1) day, or should we plan on more than one day? Answer: The Operational test (pp 10.2.1) can be run simultaneously on all three ovens and can be completed during a single 8 hour shift. The System Accuracy Tests (pp 10.2.2) can be run concurrently with the Operational test. The Temperature Uniformity Surveys take much longer and due to a lack of equipment, we can only run a survey on one oven at a time and would take longer than 1 day to complete all three ovens. However, the manufacturer's representative need not be present while that is completed.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AFMC/OOALC/FA8224-11-T-0011-0001/listing.html)
 
Place of Performance
Address: 533 CMMXS, 7169 6th Street Bldg 510, Hill AFB, Utah, 84050, United States
Zip Code: 84050
 
Record
SN02412581-W 20110401/110330234207-3369224f347dbf2d890ecfa65568336e (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.