Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF APRIL 07, 2011 FBO #3421
SOLICITATION NOTICE

J -- Annual Maintenance RFQ

Notice Date
4/5/2011
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
Department of the Navy, Bureau of Medicine and Surgery, NMC Portsmouth, 54 Lewis Minor St, Portsmouth, Virginia, 23708-2297, United States
 
ZIP Code
23708-2297
 
Solicitation Number
N00183-11-T-0148
 
Archive Date
4/30/2011
 
Point of Contact
Harold D Woodley, Phone: 757-953-7276, Danny W Davis, Phone: 757-953-2910
 
E-Mail Address
harold.woodley@med.navy.mil, danny.davis2@med.navy.mil
(harold.woodley@med.navy.mil, danny.davis2@med.navy.mil)
 
Small Business Set-Aside
Total Small Business
 
Description
Section B - Supplies or Services and Prices ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0001 12 Months Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Scanning System, Ultrasonic Model: 2101 Falcon PA #: 18353912 Serial #: 20041847622 Location: 2/441813 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQGY001 PURCHASE REQUEST NUMBER: N0018312RQGY001 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0002 12 Months Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Convex array Transducer Model: Associated with CLIN 0001 PA #: Associated with CLIN 0001 Serial #: Associated with CLIN 0001 Location: 2/441813 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQGY001 PURCHASE REQUEST NUMBER: N0018312RQGY001 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0003 12 Months Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Linear array Transducer Model: Associated with CLIN 0001 PA #: Associated with CLIN 0001 Serial #: Associated with CLIN 0001 Location: 2/441813 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQGY001 PURCHASE REQUEST NUMBER: N0018312RQGY001 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0004 12 Months Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Convex Rectal Transducer 7.5MHz MFI Model: Associated with CLIN 0001 PA #: Associated with CLIN 0001 Serial #: Associated with CLIN 0001 Location: 2/441813 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQGY001 PURCHASE REQUEST NUMBER: N0018312RQGY001 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0005 12 Months Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Convex Rectal Transducer 7.5MHz MFI Model: Associated with CLIN 0001 PA #: Associated with CLIN 0001 Serial #: Associated with CLIN 0001 Location: 2/441813 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQGY001 PURCHASE REQUEST NUMBER: N0018312RQGY001 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0006 12 Months Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Aony B/W Video Graphic Printer Model: Associated with CLIN 0001 PA #: Associated with CLIN 0001 Serial #: Associated with CLIN 0001 Location: 2/441813 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQGY001 PURCHASE REQUEST NUMBER: N0018312RQGY001 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0007 12 Months Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Single Element Probe Adapter for 210x Model: Associated with CLIN 0001 PA #: Associated with CLIN 0001 Serial #: Associated with CLIN 0001 Location: 2/441813 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQGY001 PURCHASE REQUEST NUMBER: N0018312RQGY001 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0008 12 Months Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Scanning System, Ultrasonic Model: 2202 PA #: 101396 Serial #: 1884354 Location: 2/2/GEN SURG See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQGS001 PURCHASE REQUEST NUMBER: N0018312RQGS001 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0009 12 Months Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Convex Array Transducer Model: Associated with CLIN 0008 PA #: Associated with CLIN 0008 Serial #: Associated with CLIN 0008 Location: Associated with CLIN 0008 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQGS001 PURCHASE REQUEST NUMBER: N0018312RQGS001 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0010 12 Months Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Linear Array Transducer Model: Associated with CLIN 0008 PA #: Associated with CLIN 0008 Serial #: Associated with CLIN 0008 Location: Associated with CLIN 0008 See Section C for Statement of Work FOB: Destination MILSTRIP: N0018312RQGS001 PURCHASE REQUEST NUMBER: N0018312RQGS001 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0011 12 Months Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Sony B/W Video Graphic Printer Model: Associated with CLIN 0008 PA #: Associated with CLIN 0008 Serial #: Associated with CLIN 0008 Location: Associated with CLIN 0008 See Section C for Statement of Work FOB: Destination MILSTRIP: N0018312RQGS001 PURCHASE REQUEST NUMBER: N0018312RQGS001 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0012 12 Months Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Convex Rectal Transducer 7.5Hz MFI Model: Associated with CLIN 0008 PA #: Associated with CLIN 0008 Serial #: Associated with CLIN 0008 Location: Associated with CLIN 0008 See Section C for Statement of Work FOB: Destination MILSTRIP: N0018312RQGS001 PURCHASE REQUEST NUMBER: N0018312RQGS001 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0013 12 Months Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Sony B/W Video Graphic Printer Model: Associated with CLIN 0008 PA #: Associated with CLIN 0008 Serial #: Associated with CLIN 0008 Location: Associated with CLIN 0008 See Section C for Statement of Work FOB: Destination MILSTRIP: N0018312RQGS001 PURCHASE REQUEST NUMBER: N0018312RQGS001 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0014 12 Months Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Single Element Probe Adapter for 210x Model: Associated with CLIN 0008 PA #: Associated with CLIN 0008 Serial #: Associated with CLIN 0008 Location: Associated with CLIN 0008 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQGS001 PURCHASE REQUEST NUMBER: N0018312RQGS001 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0015 12 Months Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Scanning System, Ultrasonic Model: 2101 Falcon PA #: 18388068 Serial #: 20021839604 Location: 2/221712 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQUR004 PURCHASE REQUEST NUMBER: N0018312RQUR004 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0016 12 Months Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Convex Array Transducer Model: 8830 PA #: Associated with CLIN 0015 Serial #: Associated with CLIN 0015 Location: Associated with CLIN 0015 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQUR004 PURCHASE REQUEST NUMBER: N0018312RQUR004 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0017 12 Months Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Linear Array Transducer Model: 8840 PA #: Associated with CLIN 0015 Serial #: Associated with CLIN 0015 Location: Associated with CLIN 0015 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQUR004 PURCHASE REQUEST NUMBER: N0018312RQUR004 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0018 12 Months Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Convex Rectal Transducer 7.5MHz MFI Model: 8808 PA #: Associated with CLIN 0015 Serial #: Associated with CLIN 0014 Location: Associated with CLIN 0014 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQUR004 PURCHASE REQUEST NUMBER: N0018312RQUR004 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0019 12 Months Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Convex Rectal Transducer 7.5MHz MFI Model: 8808 PA #: Associated with CLIN 0015 Serial #: Associated with CLIN 0015 Location: Associated with CLIN 0015 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQUR004 PURCHASE REQUEST NUMBER: N0018312RQUR004 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0020 12 Months Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Sony B/W Video Graphic Printer Model: 895UP PA #: Associated with CLIN 0015 Serial #: Associated with CLIN 0015 Location: Associated with CLIN 0015 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQUR004 PURCHASE REQUEST NUMBER: N0018312RQUR004 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0021 12 Months Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Single Element Probe Adapter for 210x Model: UA1255 PA #: Associated with CLIN 0015 Serial #: Associated with CLIN 0015 Location: Associated with CLIN 0015 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQUR004 PURCHASE REQUEST NUMBER: N0018312RQUR004 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0022 12 Months Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Scanning System, Ultrasonic Model: 2101A3 PA #: 101724 Serial #: 1886314 Location: UROLOGY See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQUR004 PURCHASE REQUEST NUMBER: N0018312RQUR004 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0023 12 Months Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Convex Array Transducer Model: Associated with CLIN 0022 PA #: Associated with CLIN 0022 Serial #: Associated with CLIN 0022 Location: Associated with CLIN 0022 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQUR004 PURCHASE REQUEST NUMBER: N0018312RQUR004 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0024 12 Months Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Linear Array Transducer Model: Associated with CLIN 0022 PA #: Associated with CLIN 0022 Serial #: Associated with CLIN 0022 Location: Associated with CLIN 0022 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQUR004 PURCHASE REQUEST NUMBER: N0018312RQUR004 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0025 12 Months Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Sony B/W Video Graphic Printer Model: Associated with CLIN 0022 PA #: Associated with CLIN 0022 Serial #: Associated with CLIN 0022 Location: Associated with CLIN 0022 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQUR004 PURCHASE REQUEST NUMBER: N0018312RQUR004 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0026 12 Months Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Convex Rectal Transducer 7.5MHz MFI Model: Associated with CLIN 0022 PA #: Associated with CLIN 0022 Serial #: Associated with CLIN 0022 Location: Associated with CLIN 0022 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQUR004 PURCHASE REQUEST NUMBER: N0018312RQUR004 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0027 12 Months Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Sony B/W Video Graphic Printer Model: Associated with CLIN 0022 PA #: Associated with CLIN 0022 Serial #: Associated with CLIN 0022 Location: Associated with CLIN 0022 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQUR004 PURCHASE REQUEST NUMBER: N0018312RQUR004 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0028 12 Months Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Single Element Probe Adapter for 210x Model: Associated with CLIN 0022 PA #: Associated with CLIN 0022 Serial #: Associated with CLIN 0022 Location: Associated with CLIN 0022 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQUR004 PURCHASE REQUEST NUMBER: N0018312RQUR004 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0029 12 Months OPTION Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Scanning System, Ultrasonic Model: 2101 Falcon PA #: 18353912 Serial #: 20041847622 Location: 2/441813 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQGY001 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0030 12 Months OPTION Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Convex array Transducer Model: Associated with CLIN 0029 PA #: Associated with CLIN 0029 Serial #: Associated with CLIN 0029 Location: 2/441813 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQGY001 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0031 12 Months OPTION Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Linear array Transducer Model: Associated with CLIN 0029 PA #: Associated with CLIN 0029 Serial #: Associated with CLIN 0029 Location: 2/441813 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQGY001 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0032 12 Months OPTION Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Convex Rectal Transducer 7.5MHz MFI Model: Associated with CLIN 0029 PA #: Associated with CLIN 0029 Serial #: Associated with CLIN 0029 Location: 2/441813 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQGY001 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0033 12 Months OPTION Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Convex Rectal Transducer 7.5MHz MFI Model: Associated with CLIN 0029 PA #: Associated with CLIN 0029 Serial #: Associated with CLIN 0029 Location: 2/441813 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQGY001 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0034 12 Months OPTION Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Sony B/W Video Graphic Printer Model: Associated with CLIN 0029 PA #: Associated with CLIN 0029 Serial #: Associated with CLIN 0029 Location: 2/441813 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQGY001 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0035 12 Months OPTION Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Single Element Probe Adapter for 210x Model: Associated with CLIN 0029 PA #: Associated with CLIN 0029 Serial #: Associated with CLIN 0029 Location: 2/441813 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQGY001 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0036 12 Months OPTION Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Scanning System, Ultrasonic Model: 2202 PA #: 101396 Serial #: 1884354 Location: 2/2/GEN SURG See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQGS001 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0037 12 Months OPTION Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Convex Array Transducer Model: Associated with CLIN 0036 PA #: Associated with CLIN 0036 Serial #: Associated with CLIN 0036 Location: Associated with CLIN 0036 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQGS001 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0038 12 Months OPTION Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Linear Array Transducer Model: Associated with CLIN 0036 PA #: Associated with CLIN 0036 Serial #: Associated with CLIN 0036 Location: Associated with CLIN 0036 See Section C for Statement of Work FOB: Destination MILSTRIP: N0018312RQGS001 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0039 12 Months OPTION Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Sony B/W Video Graphic Printer Model: Associated with CLIN 0036 PA #: Associated with CLIN 0036 Serial #: Associated with CLIN 0036 Location: Associated with CLIN 0036 See Section C for Statement of Work FOB: Destination MILSTRIP: N0018312RQGS001 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0040 12 Months OPTION Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Convex Rectal Transducer 7.5Hz MFI Model: Associated with CLIN 0036 PA #: Associated with CLIN 0036 Serial #: Associated with CLIN 0036 Location: Associated with CLIN 0036 See Section C for Statement of Work FOB: Destination MILSTRIP: N0018312RQGS001 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0041 12 Months OPTION Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Sony B/W Video Graphic Printer Model: Associated with CLIN 0036 PA #: Associated with CLIN 0036 Serial #: Associated with CLIN 0036 Location: Associated with CLIN 0036 See Section C for Statement of Work FOB: Destination MILSTRIP: N0018312RQGS001 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0042 12 Months OPTION Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Single Element Probe Adapter for 210x Model: Associated with CLIN 0036 PA #: Associated with CLIN 0036 Serial #: Associated with CLIN 0036 Location: Associated with CLIN 0036 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQGS001 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0043 12 Months OPTION Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Scanning System, Ultrasonic Model: 2101 Falcon PA #: 18388068 Serial #: 20021839604 Location: 2/221712 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQUR004 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0044 12 Months OPTION Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Convex Array Transducer Model: 8830 PA #: Associated with CLIN 0043 Serial #: Associated with CLIN 0043 Location: Associated with CLIN 0043 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQUR004 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0045 12 Months OPTION Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Linear Array Transducer Model: 8840 PA #: Associated with CLIN 0043 Serial #: Associated with CLIN 0043 Location: Associated with CLIN 0043 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQUR004 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0046 12 Months OPTION Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Convex Rectal Transducer 7.5MHz MFI Model: 8808 PA #: Associated with CLIN 0043 Serial #: Associated with CLIN 0043 Location: Associated with CLIN 0043 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQUR004 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0047 12 Months OPTION Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Convex Rectal Transducer 7.5MHz MFI Model: 8808 PA #: Associated with CLIN 0043 Serial #: Associated with CLIN 0043 Location: Associated with CLIN 0043 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQUR004 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0048 12 Months OPTION Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Sony B/W Video Graphic Printer Model: 895UP PA #: Associated with CLIN 0043 Serial #: Associated with CLIN 0043 Location: Associated with CLIN 0043 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQUR004 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0049 12 Months OPTION Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Single Element Probe Adapter for 210x Model: UA1255 PA #: Associated with CLIN 0043 Serial #: Associated with CLIN 0043 Location: Associated with CLIN 0043 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQUR004 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0050 12 Months OPTION Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Scanning System, Ultrasonic Model: 2101A3 PA #: 101724 Serial #: 1886314 Location: UROLOGY See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQUR004 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0051 12 Months OPTION Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Convex Array Transducer Model: Associated with CLIN 0050 PA #: Associated with CLIN 0050 Serial #: Associated with CLIN 0050 Location: Associated with CLIN 0050 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQUR004 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0052 12 Months OPTION Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Linear Array Transducer Model: Associated with CLIN 0050 PA #: Associated with CLIN 0050 Serial #: Associated with CLIN 0050 Location: Associated with CLIN 0050 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQUR004 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0053 12 Months OPTION Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Sony B/W Video Graphic Printer Model: Associated with CLIN 0050 PA #: Associated with CLIN 0050 Serial #: Associated with CLIN 0050 Location: Associated with CLIN 0050 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQUR004 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0054 12 Months OPTION Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Convex Rectal Transducer 7.5MHz MFI Model: Associated with CLIN 0050 PA #: Associated with CLIN 0050 Serial #: Associated with CLIN 0050 Location: Associated with CLIN 0050 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQUR004 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0055 12 Months OPTION Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Sony B/W Video Graphic Printer Model: Associated with CLIN 0050 PA #: Associated with CLIN 0050 Serial #: Associated with CLIN 0050 Location: Associated with CLIN 0050 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQUR004 NET AMT ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT 0056 12 Months OPTION Annual Maintenance FFP Manufacturer: B-K Medical Systems Nomenclature: Single Element Probe Adapter for 210x Model: Associated with CLIN 0050 PA #: Associated with CLIN 0050 Serial #: Associated with CLIN 0050 Location: Associated with CLIN 0050 See Section C for Statement of Work. FOB: Destination MILSTRIP: N0018312RQUR004 NET AMT Section C - Descriptions and Specifications CLAUSES INCORPORATED BY FULL TEXT CLAUSES INCORPORATED BY FULL TEXT DESCRIPTION/SPECIFICATION/WORK STATEMENT Statement of Work Selected vendor must be able to provide full contract support immediately upon award of a resulting order. Vendor will provide full maintenance support for the items listed in Section B and all support items / components. This contract shall provide for maintenance services which include on-site corrective repairs, normal working hour coverage (8:00 A.M. to 4:30 P.M. Monday through Friday excluding Federal holidays) and 24-hour emergency service and routine preventive maintenance services to Department of Defense owned equipment, as listed on the: DD Form 1155 "Order for Supplies or Services". It shall include all systems, subsystem components, and assemblies, (i.e.: contractor responsible for total maintenance of entire system). All maintenance provisions shall apply to hardware, firmware, and software, as appropriate, unless otherwise stated. 1. General a. The Contractor shall comply with Federal, State, and Local Laws, plus any Federal Regulations as applicable to the performance of this contract. b. The Contractor shall not accept any instructions issued by any person employed by the U. S. Government, other than: the Contracting Officer (KO), or Biomedical Engineering Division (BME), all acting within the limits of their authority. c. The Contractor shall be qualified / authorized by the Original Equipment Manufacturer (OEM) in the repair of all equipment listed within this contract. Contractor shall maintain current (within 2 years) qualifications throughout entire contract period. Qualification includes but not limited to the certification of all repair persons and repair facilities by the OEM as being trained / qualified to perform required repairs. The Government shall maintain the right to seek proof of qualification prior to award and anytime during contract period of performance. 2. Scope of Work a. The Contractor shall provide trained, experienced, English speaking personnel, labor, tools, diagnostic equipment, software, test phantoms, material, supplies, transportation, parts and equipment necessary to perform Preventive Maintenance (PM), Calibration (CAL), Safety testing (ST) and corrective maintenance. b. The Contractor shall provide telephonic communications with the Government to discuss technical matters relating to the performance of this contract. A systems operator will be made available to answer technical questions regarding system operations and applications. c. Equipment listed in this contract will be maintained to meet the original equipment manufacturer's (OEM's) specifications. d. Equipment and associated components shall be serviced as listed on: DD Form 1155, "Order for Supplies or Services". e. The Contractor Point of Contact (POC). The Contractor shall provide in writing the name and telephone number of a primary and alternate English-speaking individual to act as their representative for the scheduling and coordination of service calls, and to be responsible for the coordination of the contract with the Government. 3. Government furnished property, Materials and Services. a. The Contractor representative(s) at each site is encouraged to request a pre-maintenance inspection prior to the onset of the contract. As all apparent discrepancies must be identified upon submittal of quote, any and all claims must be received within 30 days of contract award or prior to contract start which ever occurs first. All non-apparent / hidden discrepancies, must be identified no later that the first scheduled preventative maintenance. Any claims resulting from hidden defects must be received within 30 days of first scheduled preventative maintenance. Any equipment found to be inoperable during this pre-maintenance inspection would be repaired using a separate purchase order. The cost of repairs shall not exceed contractor's normal retail rate for required repairs. The government certifies that the equipment to be maintained under this contract will be in good operating condition on the effective date of this contract. For the purpose of this contract, the clause, "good operating condition" means the conditions necessary for the equipment to function as intended without corrective maintenance. The Contractor agrees to leave the equipment in good operating condition at the expiration of this contract. During the final week of this contract, the Government will make final inspection of the equipment. Any correction of deficiencies noted during this inspection shall be resolved prior to contract end. The Government reserves the right to request the repair (at no additional cost to the Government) of items identified with latten defects after contract termination, when it has been determined that defects either are a result of contractor's performance or should have been discovered during normal performance of work under this contract. b. The government will be responsible for maintaining the proper environment, including utilities and site requirements necessary for the system to function properly as specified by the OEM. c. The Government will operate the system in accordance with the instruction manual provided by the OEM. d. The Government will not be responsible for the damage or loss due to fire, theft, accident, or other disaster of Contractor supplies, materials, or for the personal belongings brought onto Government property by Contractor's personnel. 4. Contractor Furnished Property and Material. a. The Contractor shall provide all service literature, reference publications, laptop computers and diagnostic software to be used by the contractor service technicians and as required for the completion of the services in accordance with this contract. 5. Replacement Parts. a. The Contractor shall have ready access to unique and/or high mortality replacement parts. All parts supplied shall be compatible with the existing system. In the event that replacements parts are required to be shipped. Shipping shall be performed in the fastest reasonable means possible (i.e., next day air) at no additional cost to the Government. b. The Contractor shall at their expense, replace all worn or defective parts necessary to restore the equipment to 100% operational condition as specified by the OEM. c. Contractor installed replacement parts shall become the property of the Government and the replaced malfunctioning part shall become the property of the Contractor. Replaced items shall be properly disposed of at no additional cost to the Government (contractor to pay all "environmental fees" where required). d. Freight, postage, and storage charges associated with shipment and receipt of replacement parts, and the return of parts shall be the responsibility of the Contractor. e. All replacement parts shall be new and certified as OEM replacement parts. In the event that new parts are not available, rebuilt parts and sub-assemblies are allowed provided that they are warranted to be free of defects for a period of time that meets or exceeds warranties of similar replacement parts. The contractor shall specifically annotate on the final Field Service report the use and identification of rebuilt parts and the period of warranty. When discrepancies occur, the Government will make the final determination on whether a replacement part is of equal or better quality. f. The Contractor must include software revisions and updates (field service changes), which are required due to FDA, or manufacturer announced safety-hazard recall, to include FDA Year 2000 Compliance Directive, as part of the contract at no additional cost to the Government. Updates shall be performed as soon as possible after release, but no later than the first scheduled Preventative Maintenance Inspection after release. For any updates that have been identified as critical, or required for the proper operation of equipment by the OEM, contractor shall provide installation within 30 days of release regardless of Preventative Maintenance Schedules. Specific Tasks. 6. Contractor Report Requirements. a. During normal duty hours, Contracted Field Service Engineer (FSE) personnel shall check-in with the Biomedical Engineering Division upon arrival at the Government site and again prior to departure. (Biomedical Engineering located in Build-250 1st floor; 757-953-5336). The Contractor FSEs shall personally notify Biomedical Engineering (BME) of problems that result in the equipment being left disabled upon their departure. After normal duty hours, Contractor FSE's shall notify the Officer of the Day Desk (Bldg 2, 2nd Floor) and the systems operator designated by BME. b. The Contractor shall provide to BME a full service report within two (2) days after completion of all service performed. The service report shall include, but not be limited to: contract number, equipment description (model, serial number, equipment control number) contractor's log number, detailed description of the service(s) performed, replacement part(s) information (part number, part value, nomenclature, unit price, manufacturer, if not OEM, and whether the part is new/used/reconditioned), the completion date and time, man-hours expended and the hourly rate normally charged for the type of service performed, model and serial numbers, and the name of the FSE performing the service. In the event that agents / sub-contractor's are used in the performance of repairs, said agent shall be identified on the service report by company name and contact information (i.e., telephone number). Additionally contractor will be required to affix a tag on equipment upon the completion of a preventative maintenance inspection. Tag may either be a "sticker" or "hanging tag". As a minimum the tag shall contain: the name of the contractor, technician performing inspection and date of inspection legibly printed. 7. Contractor Responsibility. a. The Contractor shall be responsible for the repair/replacement of damaged Government owned equipment and property due to the negligence of the Contractor or his representatives. All such replacement or repair shall be at the Contractor's expense and shall be inspected to the satisfaction of the KO or appointed representative. 8. Preventive Maintenance Services. a. In accordance with Naval Medical Logistics Command (NAVMEDLOGCOM) Risk Assessment Criteria, preventive maintenance shall be performed two (2) time per year in accordance with the Original Equipment Manufactures (OEM) recommendations. b. The Government shall select the months in which preventive maintenance services are to be performed. The preventive maintenance visits shall be performed during the following months: June (The Government Fiscal Year runs: October through September). The Contractor shall schedule and complete preventive maintenance services prior to the 15th of the selected month. c. All test equipment used in the performance of this contract must be calibrated (if required / as required by manufacture of test equipment) and shall be in compliance with Joint Commission on Accreditation of Healthcare Organizations (JCAHO), Original Equipment Manufacturer (OEM) and Federal Drug Administration (FDA) standards as required. 9. Corrective Maintenance a. Normal Working Hour Maintenance Coverage Maintenance Coverage will be Monday through Friday, between 8:00 A.M. to 4:30 P.M. A contractor Service Tech shall respond via telephone within 2 hours after receipt of trouble call, and provide on-site service no later than the close of business (4:30 pm) on the next business day. Equipment shall be operational within 48 hours. The Government reserves the right to deduct from the Contractor's payment an amount not to exceed the hourly rate of $50.00 per hour for each hour the Contractor fails to respond, as specified in the contract. a. In the event that emergency service outside the normal working hours are required by the Government, additional work shall be billable to the Government at published commercial rates, and negotiated and approved by a Contracting Officer prior to services rendered. b. Government request for corrective maintenance will be placed by BME, to the Contractor's POC. Corrective Maintenance shall be completed during the hours specified in the contract. c. The Contractor shall assign a unique Log/Reference Number to each Government request for corrective Maintenance. d. Contractor's response to requests for service may include telephone consultation with the equipment user/operator and a Contractor FSE. Telephone consultation shall: 1) provide instruction in determining operator error; 2) to determine the most likely cause of the problem; 3) to determine if resolution of the problem requires the dispatch of a FSE; and 4) to identify replacement parts likely to be required in order to return the equipment to 100% operational condition as specified by the OEM. e. Contractor's pricing shall be inclusive of all cost including parts, labor, travel and shipping, unless otherwise indicated. Any/all exclusions are listed as follows: No Exclusions f. The Contractor shall have his/her own service manuals, specifications, schematic diagrams, and parts lists to assist in the evaluation/repair of all equipment included in this contract. 10. Removal of Government Property a. Whenever the repair of equipment cannot be performed at the Government site as determined by the Contractor, the Contractor shall notify BME who will make arrangements for the Contractor to remove the item to the Contractor's designated site. The Contractor may be required to sign a Government form accepting responsibility for the Government equipment. The Contractor shall provide a detailed description of removed items. For associated items / accessories, contractor to provide a detailed description and quantities of items to be removed. Description to include as a minimum manufacturers serial numbers and equipment control number (ECN) of all equipment / items removed. In the event that items / sub-assemblies / accessories are repaired via "Repair by Replacement" a detailed description of replaced items is to be included upon return of repaired components. b. All charges resulting from a Contractor determined requirement to transport Government owned property, covered by this contract, to and from an alternate repair location shall be the responsibility of the Contractor. 11. Equipment Modification Upgrades a. The Contractor shall only incorporate OEM specified modifications, alterations and upgrades. Approval shall be obtained from BME prior to the Contractor installation of any modification, alteration, or upgrades. b. The Contractor shall maintain contact with the OEM to determine the requirement for field modifications and to ensure accomplishment of these modifications in accordance with the time schedule set forth by the OEM. c. The Government shall not alter the system without prior notification to the Contractor. d. The contractor at no additional cost shall provide software updates to the Government. Installation of updates will be left to the discretion of the Government. All supplied software is to be warranted current and free of defects such as viruses. 12. Service Beyond the Scope of the Contract a. The Contractor shall immediately, but not later than 24 consecutive hours after discovery, notify BME, in writing, of the existence or the development of any defects in, or repair required to the scheduled equipment, which the Contractor considers they are not responsible for under the terms of this contract. b. At the same time of the notification, the Contractor shall furnish BME with written estimate of the cost to make the necessary repairs. Repairs considered by the Contracting Officer to be outside the scope of this contract shall not be covered under this contract, but shall be ordered under a separate purchase order.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/BUMED/N00183/N00183-11-T-0148/listing.html)
 
Place of Performance
Address: Naval Medical Center Portsmouth, 54 Lewis Minor Street, Building 250, Portsmouth, Virginia, 23708, United States
Zip Code: 23708
 
Record
SN02417227-W 20110407/110405234646-48913e914fd7d59bb205aaf9d834547a (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.