SOLICITATION NOTICE
Z -- Design-Build, Repair Gas Mains (9000 & 10000 Areas) Project Number: MPLS 06-9041
- Notice Date
- 4/7/2011
- Notice Type
- Presolicitation
- NAICS
- 237120
— Oil and Gas Pipeline and Related Structures Construction
- Contracting Office
- Department of the Air Force, Air Education and Training Command, Lackland AFB - 802th Contracting Squadron, 1655 Selfridge Avenue, Lackland AFB, Texas, 78236-5253, United States
- ZIP Code
- 78236-5253
- Solicitation Number
- FA3047-11-B-0004-GasMains
- Point of Contact
- Chad J. Stemick, Phone: 2106711712, JACKIE L. MURRAY, Phone: 2106711711
- E-Mail Address
-
chad.stemick@us.af.mil, jackie.murray@us.af.mil
(chad.stemick@us.af.mil, jackie.murray@us.af.mil)
- Small Business Set-Aside
- HUBZone
- Description
- TITLE: Design-Build, Repair of Gas Mains (9000 & 10000 Areas) Project Number: MPLS 06-9041 PROJECT SCOPE Contractor shall provide a complete design (Title I services A & B) for the replacement of approximately 10000 linear feet of gas main piping in the 9,000 and 10,000 Areas. All work shall be in conformance with the drawings and specifications and applicable codes, standards and regulations and shall include the furnishing of all materials, labor, plant, tools, equipment, and services necessary and incidental thereto. The work required to be performed by the contractor shall consist of but is not limited to the following principal items: DESIGN Contractor shall provide a complete design for the replacement of gas mains. The design shall consist of plans, specifications, design analysis and cost estimate. A design package shall be submitted at the 65% and 95% stages of design. The 65% design submittal will be reviewed and accepted by the government prior to continuation to 95%. Construction will commence upon acceptance of the 95% design submittal. GAS MAIN REPLACEMENT Existing gas piping shall be abandoned in place. The contractor shall provide all materials, labor, plant, tools equipment and services necessary to provide a complete and fully functioning system in compliance with design drawings, specifications and submittal register and in conformance with all applicable codes standards and regulations.. In this contract the contractor shall perform all the work but not limited to the following: • Installation of approximately 5800 linear feet of 6"polyethylene pipe and approximately 1800 linear feet of 4" polyethylene pipe, approximately 850 linear feet of 2" polyethylene pipe and approximately 1300 linear feet of 1-1/4" polyethylene pipe. • Replace two regulator stations. • Relocate approximately 20 service lines from existing mains to new mains. • Replace existing service valves with a new polyethylene valve at each service. • Replace approximately 20 main line isolation valves with polyethylene valves. • Contractor shall carefully restore all excavated areas to its original condition after the underground work is completed. Period of Performance and Magnitude: The magnitude for this requirement is between $1,000,000.00 and $5,000,000.00. The period of performance is 75 days for design and 247 days for construction. SET ASIDE: HUBZone NAICS Code: North American Industry Classification System (NAICS) code. The applicable NAICS code for this acquisition is 237120 (Oil and Gas Pipeline and Related Structures Construction) with a small business size standard of $33,500,000.00. BID BOND: In accordance with FAR 52.228-1 Bid Guarantee an original bid bond must be submitted with your bid package to be responsive. The amount of the bid guarantee shall be 20% of the bid price or $3,000,000.00, whichever is less. Bids are due on 07 Jun 11 (Estimated) no later than 11:00am (CST). Specific instructions can be found in Section H, L and M of the upcoming Invitation for Bid (IFB). Pre-Bid Conference / Site Visit is Scheduled for 20 May 11 (Estimated) at 9:00am (CST). Location: 802D Contracting Squadron 1655 Selfridge Ave, Bldg. 5450, (Legacy Room), Lackland AFB, TX 78236. It is anticipated that the following viewers will be needed to view the solicitation: Microsoft Word (.doc), Adobe Acrobat Reader (.pdf), WinZip (.zip or.exe.), and / or AutoCAD. More information concerning these viewers can be found on the FBO website. Note: Any prospective contractor must be registered in the Central Contractor Registration (CCR) database in order to be eligible for award. Registration requires applicants to have a DUNS number from Dun and Bradstreet. Registration may take up to three weeks to process. Recommend registering immediately in order to be eligible for timely award. Effective 01 Jan, 2005, the Federal Acquisition Regulation (FAR) requires the use of Online Representations and Certifications Application (ORCA) in Federal solicitations as part of the proposal submission process. All prospective contractors submitting an offer in response to the subject solicitation must go to http://www.bpn.gov/ to add/update its ORCA record. Primary POC is Mr. Basilio Solis, Contract Specialist at (210) 671-1706; email:basilio.solis@us.af.mil; Alternate POC is Ryan D. Bueno, Contract Specialist at (210) 671-0644; email: ryan.bueno.1@us.af.mil or Mr. Jack Murray, Contracting Officer at (210) 671-1711; email: Jackie.murray@us.af.mil.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AETC/LackAFBCS/FA3047-11-B-0004-GasMains/listing.html)
- Place of Performance
- Address: Lackland AFB- 802 Contracting Squadron, San Antonio, Texas, 78236, United States
- Zip Code: 78236
- Zip Code: 78236
- Record
- SN02419396-W 20110409/110407234431-f54c0b85fcc77fdc1278629104f30cf0 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |