Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF APRIL 09, 2011 FBO #3423
DOCUMENT

Y -- Construction Project, RM09-2494 - Energy Conservation & Repairs to Sub Enclosures (RSCs), Naval Shipyard, Portsmouth, New Hampshire - Attachment

Notice Date
4/7/2011
 
Notice Type
Attachment
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
N40085 NAVFAC MID-ATLANTIC Naval Facilities Engineering Command, Mid-Atlantic Code AQ, 9742 Maryland Avenue Norfolk, VA
 
Solicitation Number
N4008511R7246
 
Response Due
5/9/2011
 
Archive Date
5/24/2011
 
Point of Contact
Philip Cole (757)341-1970.
 
E-Mail Address
<!--
 
Small Business Set-Aside
N/A
 
Description
THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR PROPOSAL. THERE WILL NOT BE A SOLICITATION, SPECIFICATIONS, OR DRAWINGS AVAILABLE AT THIS TIME. The Naval Facilities Engineering Command, Mid-Atlantic is seeking eligible small business firms capable of performing Construction Services for RM09-2494, Energy Conservation and Repairs to Submarine Enclosures at Dry Dock #2, Naval Shipyard, Portsmouth, New Hampshire. The contract will provide: The repair and modernization of the removable submarine covers (RSCs), which are mission critical (MDI 97) air conditioned structures that enclose submarines during maintenance and refueling/defueling availabilities in Dry Dock #2. The RSCs are comprised of 17 stacks and 6 stair towers that will be disassembled and transported off the Shipyard to a vendor's facility to be blasted and painted. Project includes the installation of new hardware and fall protection anchors, structural repairs, and major upgrades to HVAC, electrical, fire protection and lighting systems. Additional work in Dry Dock #2 will include blasting, painting and minor structural repair of the west stairway at Building 343 and repair of the structural tie downs. Energy savings will be gained through repair of the 14 inoperable existing Rooftop HVAC Units (RTUs) that currently prevent energy recovery of conditioned air, thereby heating and cooling spaces with 100% make-up air. With air-to-air heat exchange restored, two high efficiency 150 ton chillers will be installed and attached to existing utilities to provide adequate conditioning to both sides of the submarine, as well as provide required redundancy in the event of casualty operation. Enhanced controls and metering devices throughout will regulate conditioning with new variable speed fans to react to opened compartments limiting heating and cooling losses. Further savings will be gained by cladding RSC units with additional R-15 metal insulated panels, and refurbishing existing insulation and weatherization throughout. Total energy reduction of approximately 76% is expected over current baseline operations. The magnitude of this project is between $25,000,000 and $100,000,000. All Service Disabled Veteran (SDV) small businesses certified HUBZone small businesses, certified 8(a) small businesses, and other certified small businesses are encouraged to respond. Upon review of industry response to this Sources Sought Synopsis, the Government will determine whether a set-aside acquisition in lieu of full and open competition is in the Government ™s best interest. This office anticipates award of a contract for these construction requirements by September 2011. The appropriate NAICS code for this procurement is 236220 and the small business size standard is $33,500,000. THIS SYNOPSIS IS NOT A REQUEST FOR PROPOSAL. This synopsis is a market research tool being used to determine the availability and adequacy of potential small business sources prior to determining the method of acquisition and ultimate issuance of an award. The Government is not obligated to and will not pay for any information received from the potential sources as a result of this synopsis. It is requested that interested small businesses submit to the contracting officer a brief capabilities statement package (no more than 10 pages in length, single spaced, 12 point font minimum) demonstrating ability to perform the requested services. The documentation shall address, as a minimum, the following: (1) Relevant Experience to include experience in performing efforts of similar value, size, and scope within the last five (5) years including contract number, indication of whether your firm acted as a prime or subcontractor, contract value, Government/Agency point of contact and current telephone number, and a brief description of how the contract relates to the technical requirements described herein. (2) Company Profile to include the following: 1. Number of employees. 2. Office location(s). 3. Available bonding capacity per contract. 4. DUNS number. 5. CAGE Code. 6. Small business designation/status claimed. 7. Annual revenue. RESPONSES ARE DUE NLT 09 May 2011, NLT 2:00 PM EST. LATE RESPONSES WILL NOT BE ACCEPTED. The package shall be sent to the following: Mail responses to: Naval Facilities Engineering Command Mid-Atlantic, Northeast IPT, Attn: Philip Cole 9742 Maryland Ave, Bldg. Z-144, 2nd Floor, Room 214, Norfolk, VA 23511-3095 Express deliver responses to: Naval Facilities Engineering Command Mid-Atlantic, Northeast IPT, Attn: Philip Cole 9742 Maryland Ave, Bldg. Z-144, 2nd Floor, Room 214, Norfolk, VA 23511-3095 Hand deliver responses to the Express Delivery address but to First Floor, Room 109, Attn: Philip Cole Electronic submission of the statement of capabilities package will not be accepted. Questions or comments regarding this notice may be addressed to Philip Cole either by email at philip.j.cole@navy.mil or phone 757-341-1970.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/NAVFAC/N62470HR/N4008511R7246/listing.html)
 
Document(s)
Attachment
 
File Name: N4008511R7246_Sources_Sought.pdf (https://www.neco.navy.mil/synopsis_file/N4008511R7246_Sources_Sought.pdf)
Link: https://www.neco.navy.mil/synopsis_file/N4008511R7246_Sources_Sought.pdf

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN02419925-W 20110409/110407234945-8cd712cfd9e4a34504f781edeb7158f1 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |