MODIFICATION
42 -- Request for Information for Fire Department Equipment Testing
- Notice Date
- 4/13/2011
- Notice Type
- Modification/Amendment
- NAICS
- 541380
— Testing Laboratories
- Contracting Office
- Department of the Air Force, United States Air Force Europe, 48 CONS/LGC - Lakenheath, RAF Lakenheath, Unit 5070 Box 270, RAF Lakenheath, 09461-0270
- ZIP Code
- 09461-0270
- Solicitation Number
- F3B3E21082A001
- Point of Contact
- Wendell D. Gibson, Phone: 011-44-01638522174, Anna Gulewich, Phone: 001-44-(0)-1638-52-2232
- E-Mail Address
-
wendell.gibson@lakenheath.af.mil, anna.gulewich@lakenheath.af.mil
(wendell.gibson@lakenheath.af.mil, anna.gulewich@lakenheath.af.mil)
- Small Business Set-Aside
- N/A
- Description
- 1. DESCRIPTION OF SERVICES: The contractor shall provide maintenance testing and documentation of all fire department equipment. All services shall be conducted on base and any deviation shall require preapproval by the Contracting Officer. The contractor shall provide the services listed below, Appendix A Estimated Equipment List. 2. CERTIFICATION REQUIREMENTS: All services shall be performed in accordance with the inspection and testing set forth by the manufacture and certification requirements of the National Institute for Occupational Safety and Health (NIOSH), National Fire Protection Association (NFPA), Occupational Health and Safety Administration (OSHA), and all applicable Air Force Occupational Safety and Health (AFOSH) standards. Contractor will be MSA C.A.R.E. Facility, Bauer and Holmatro certified and provide a USDOT RIN#. 3. FACILITY /EQUIPMENT REQUIREMENTS: Government facilities will be provided to the contractor at the Fire Station, building 669. The contractor will be provided an area to perform all duties as well as a computer to access the ACES-FD program. The contractor may use government furnished equipment specific for testing a piece of equipment. Any damage to the facility, equipment or computer under the use of the contractor shall be paid for by the contractor. A vehicle will be provided to the contractor to move equipment and transport between lodging and the work site. 4. MAINTENANCE AND TESTING 4.1 SCBA MASKS: Contractor shall provide service, inspection, and maintenance of all MSA masks to include confined space masks. All repairs and maintenance shall be in accordance with MSA manufactures recommendation and NFPA 1852: Standard on Selection, Care, and Maintenance of Open-Circuit Self-Contained Breathing Apparatus (SCBA) 4.2 INSPECTION OF CYLINDERS: Contractor shall provide a thorough inspection of all SCBA cylinders to include all confined space cylinders in accordance with MSA manufacturer guidance. The contractor personnel shall be certified by MSA to provide technical services for all SCBA's. 4.3 CONFINED SPACE EQUIPMENT TESTING: Contractor shall provide inspection, testing, maintenance, and re-certification of confined space equipment In accordance with manufactures recommendations. Service shall be conducted onsite and include an inventory of all systems, locations and dates on supply and demand hoses. 4.4 AIR CART AND HOSE TESTING: Contractor shall inspect, test, repair and recertify all components of the MSA confined space air cart to include all hose equipment In accordance with manufactures recommendations. 4.5 COMPRESSOR SERVICING: Contractor shall provide inspection, testing, maintenance, and re-certification of all SCBA Bauer compressors and refill stations, storage trailers shall be serviced according to respective manufacturer's recommendations. 4.6 COMPRESSOR AIR SAMPLING: Contactor shall conduct air sampling on all SCBA compressors and shall repair each until a passing sample is produced. 4.7 CALIBRATION: Contractor shall ensure all calibration systems are in compliance with ISO 10012-1 and ANSI/NCSL Z540-1 standards. Equipment to be calibrated includes: portable gas monitors, MSA test panels, compressor CO2 monitors, Biosystems, Posicheck units, level A suit testers, pump testing vacuum gauges, moisture analyzers, temperature probes, pressure and vacuum gauges. 4.8 HYDRAULIC TOOLS AND EQUIPMENT: Contractor shall provide inspection, testing, maintenance, and re-certification of all Holmatro tools, generators and hoses. All work shall be accomplished by trained and certified technicians with all work being accomplished in accordance with manufactures recommendations. 4.9 HOSE TESTING: The contractor shall inspect test and document the servicing of 17,500 feet of fire department fire hose. The testing shall be in compliance with current NFPA 1962: Standard for Inspection C are and Use of Fire Hose, Couplings, and Nozzles and the Service Testing of Fire Hose. 4.10 LADDER TESTING: Contractor shall provide inspection, testing, and recertification of 20 ground ladders in accordance with NFPA 1932 Standard on Use, Maintenance, and Service Testing of In-Service Fire Department Ground Ladders. 4.11 PUMP TESTING: The contractor shall test 9 fire pump systems on fire apparatus. Testing shall be conducted to the standards and procedures as outlined in manufactures recommendations and NFPA 1911 Standard for the Inspection, Maintenance, Testing, and Retirement of In-Service Automotive Fire Apparatus. 4.12 CONTRACT DATA REQUIREMENTS: The Contractor shall provide a final report in a binder to the department:  Annual Fit for Service Certification  Annual Visual Inspection Certificate  Hydrostatic Test Certificate (MSA are on five year schedule) - Posichek reults (this and ACES-FD replaces below)  Interpret Test Results  SCBA Mask History and Maintenance Report  Backpack History and Maintenance Report  Air Bottle History Maintenance Report  Hydrostatic Test Results  Cylinder Failure Form  Cylinder Spec Sheet  Cylinder Visual Defects Report  SCBA Compressor and Refill Station Operational Inspection and Test Certificates - Pump Test Reports -Hose Test Reports -Ladder Test Reports -Rescue Equipment Reports -Air Sample Reports -Confined Space Report -Air Cart Inspection Report -Calibration Cerificates 4.13 SPARE PARTS: The contractor shall utilize parts currently in the Government's inventory. If parts are unavailable the contractor shall get approval from the contracting officer to purchase any replacement parts.   Appendix A Estimated Equipment List RAF Mildenhall Equipment List Annual Service of Complete SCBA Units 148 Annual Service of Additional Cylinders 84 Visual Inspection of Cylinders 278 Hydrostatic Testing of Cylinders (1 time in 5 years) 262* Confined Space Equipment 4 MSA Confined Space Air Cart 1 MSA Confined Space Air Cart Hoses 13 Compressor Service - Annual 4 Air Sanmple Test 1 Air Test Samples 12 A Level Suit Testing 50 Equipment Calbration - Posicheck 1 Ladder Testing - Ground 38 Hose Testing (per foot) 17450 Pump Testing 9 Holmatro Rescue Equipment 2 Homatro Hoses and Tools 9 *As needed
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/USAFE/48CONSLGC/F3B3E21082A001/listing.html)
- Place of Performance
- Address: RAF Mildenhall, United Kingdom, RAF Mildenhall, United Kingdom
- Record
- SN02424342-W 20110415/110413235031-646c982bd2959bfb50040925d37a560d (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |