SOURCES SOUGHT
68 -- Solid and Liquid Runway Deicer
- Notice Date
- 4/14/2011
- Notice Type
- Sources Sought
- NAICS
- 325998
— All Other Miscellaneous Chemical Product and Preparation Manufacturing
- Contracting Office
- Department of the Air Force, Air Force Materiel Command, 88 CONS/PK, 1940 ALLBROOK DRIVE, WRIGHT-PATTERSON AFB, Ohio, 45433-5309, United States
- ZIP Code
- 45433-5309
- Solicitation Number
- FA8601-11-R-0069
- Point of Contact
- Ryan J. Huffman, Phone: 9375224617
- E-Mail Address
-
ryan.huffman@wpafb.af.mil
(ryan.huffman@wpafb.af.mil)
- Small Business Set-Aside
- N/A
- Description
- THIS IS A SOURCES SOUGHT SYNOPSIS FOR INFORMATION AND PLANNING PURPOSES ONLY AND IS ISSUED TO DETERMINE IF THERE ARE CONTRACTORS CAPABLE OF, AND INTERESTED IN, SUPPLYING THE REQUIRED COMMODITY/ SERVICE. CONTRACTOR MUST BE ABLE TO PROVIDE ALL ASPECTS OF THE REQUIREMENTS IDENTIFED BELOW. THE SUSPENSE DATE FOR SUBMISSION OF CAPABILITIES PACKAGES IS 1:00PM (EST) 27 APRIL 2011. THIS IS NOT A NOTICE OF RFP ISSUANCE. DESCRIPTION OF REQUIREMENT: This action will result in the award of a firm fixed price (FFP) contract for Runway Deicer. This requirement is for products that have been patented by patent number 5,350,533 on 9-27-1994. Accordingly, E-36 is the only product capable of meeting the requirements of the Air Force. This is a proprietary formulation and Cryotech is a division of General Atomics International Services Corporation, the listed assignee for this patent. The supplies are solid and liquid runway deicer including both Liquid and Solid Deicer. Service required to meet the United States Air Force Specifications are: Each load must have a certificate of analysis with every load delivered. The analysis consists of Ph value and Specific Gravity @ 68degrees and also flash point greater than 100 degrees Celcisus. Storage Stability testing must be per AMS 1435A and the fluid must meet ASTMF 1105 after storage. There must not be any evidence of separation or increase in turbidity. Cryotech is ISO 14001:2004 certified, which addresses environmental management; Cryotech is also ISO 9001:2008 certified. ISO standards assure customers that all Cryotech processes are appropriately managed and controlled. This means that all aspects of manufacturing, packaging, distribution and customer service must meet rigorous international quality standards before products are shipped to the customer. This product cannot be mixed with any other product in existing storage tanks. The existing storage tanks keep 2,000 to 3,000 gallons minimum in our tanks at all times due to our mission. The estimated yearly quantities are listed below: Liquid Runway Deier - 17,600 gallons Solid Runway Deicer (1000 KG Super Sack) - 60 sacks NAICS CODE: 325998 SIC CODE: 6810 CAPABILITIES PACKAGE: Interested firms should submit a capability statement that describes the firm's capability to provide all of the supplies and services described above. Include the firm's name, physical address, mailing address, telephone number, fax number, e-mail address, website URL, Commercial and Government Entity (CAGE), and Dun & Bradstreet Data Universal Numbering System (DUNS) Number, if available. The firm should also state if it is a small business in the NAICS Code applicable to the requirement. Capabilities statements should be brief and concise, yet clearly demonstrate the ability to provide the required solid and liquid deicer at fair and reasonable prices. POINT OF CONTACT: : Ryan Huffman, ryan.huffman@wpafb.af.mil, (937) 522-4617, fax (937) 257-3926. All correspondence sent via e-mail shall contain a subject line that reads "FA8601-11-R-0069, Solid and Liquid Runway Deicer". E-mail filters at WPAFB are designed to filter e-mails without subject lines or with suspicious subject lines or contents (i.e.,.exe or.zip files). Therefore, if the prescribed subject line is not included, the e-mail may not get through the e-mail filters. Also.zip or.exe files are prohibited attachments and may be deleted by the WPAFB e-mail filters. Ensure only.pdf,.doc, or.xls documents are sent as attachments to e-mail. The e-mail filters may delete any other form of attachments. If not using e-mail of fax, send capabilities statements to: ASC/PKOB, ATTN: Ryan Huffman 1940 Allbrook Drive, Room 109 Wright-Patterson AFB OH 45433-5309 Please include in all correspondence a reference to "FA8601-11-R-0069, Solid and Liquid Runway Deicer"
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AFMC/88 CONS/FA8601-11-R-0069/listing.html)
- Record
- SN02424690-W 20110416/110414234357-3ab086f1c6a955aa1e078b5a24f595a4 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |