SOLICITATION NOTICE
K -- Tracy 13.8-kv Switchgear/Breaker Replacement Project
- Notice Date
- 6/10/2011
- Notice Type
- Presolicitation
- Contracting Office
- Bureau of Reclamation - MP - Regional Office 2800 Cottage Way, Room E-1815 Sacramento CA 95825
- ZIP Code
- 95825
- Solicitation Number
- R11PS20185
- Response Due
- 7/29/2011
- Archive Date
- 6/9/2012
- Point of Contact
- Bettye Lou Mahoney Contracting Officer 9169785570 bmahoney@usbr.gov;
- E-Mail Address
-
Point of Contact above, or if none listed, contact the IDEAS EC HELP DESK for assistance
(EC_helpdesk@NBC.GOV)
- Small Business Set-Aside
- N/A
- Description
- The Mid-Pacific Region of the Bureau of Reclamation intends to issue a Request for Proposals (RFP) for a firm fixed-price construction contract for Tracy 13.8-kV Switchgear Breaker Replacement. This is an unrestricted solicitation and offers from all responsible concerns will be considered. The work to be performed is described below. The applicable North American Industry Classification System (NAICS) Code is 238210 and the related small business size standard is $14M. This notice is not a request for proposal and the information presented in this announcement will not obligate the Bureau of Reclamation in any manner. The estimated cost of this project is more than $10,000,000. This procurement will require 100% performance and payment bonds. Work is located approximately 10 miles north west of Tracy, California in Alameda County. Solicitation R11PS20185 will be posted to http://ideasec.nbc.gov on or about June 24, 2011. The date for receipt of proposals will be approximately July 29, 2011. The solicitation must be downloaded at the above website; no paper copy of this solicitation will be distributed. Prospective contractors MUST be actively registered in the Central Contractor Registration (CCR) database at http://www.ccr.gov to be eligible for award. Questions concerning this solicitation should be directed to Bettye Lou Mahoney by email at bmahoney@usbr.gov. The principal components of the work to be performed include: 1. Remove and dispose of the existing 13.8-kV switchgear, switchgear building, building foundation, concrete ramp and existing front panel skins (CCA 1F, CCA 2F, CCA 3F, CCA 4F, CCA 5F and CCA 6F). 2. Design, furnish, install and test 13.8-kV arc resistant switchgear assemblies; four switchgear, circuit breakers, relays, controls, meters, accessories and corresponding switchgear buildings with building foundations. 3. Furnish, install and test non-segregated phase bus duct, structural steel supports and corresponding foundations. 4. Furnish and install direct buried conduit and concrete pull box. 5. Design, furnish, install and test new 19-inch, rack mount, front panel skins (CCA 1F, CCA 2F, CCA 3F, CCA 4F, CCA 5F, CCA 6F) and include corresponding electrical devices. 6. Design, furnish, install and test new 19-inch, rack mount control boards (CCA 7, CCA 8, CCA 9 and CCA 10) and include corresponding electrical devices. 7. Furnish, install and test new control cables between Control Room and the four new switchgear, (6A, Feeder Switchgear, 8A and 11A). 8. Furnish, install and test new power and feeder cables, power cable trays and power cable splice cabinet in existing 13.8-kV (power and control) tunnel. 9. Seal existing 13.8-kV tunnel from all water leaks; fix all expansion joints, cap conduits, plug holes and clean drains. 10. Furnish, install and test current limiting reactors (CLR), corresponding non-ferrous structures and foundations. 11. Design, furnish, install and test 125 VDC battery, charger and control/distribution panel system. 12. Design, furnish, install and test Uninterruptible Power System (UPS). 13. Design, furnish, install and test fiber optic cable system. 14. Furnish, install and test 6-inch tubular rigid bus, corresponding structural steel supports and foundations. 15. Design, furnish, install and test interface equipment and structures between the two Government agencies; Western Area Power Administration (WAPA) and Bureau of Reclamation (Reclamation).
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/notices/6dc8699e28cc3f1a8f1bdcb0a99de21e)
- Place of Performance
- Address: 10 miles north west of Tracy, California in Alameda County
- Zip Code: 95825
- Zip Code: 95825
- Record
- SN02470251-W 20110612/110610235655-6dc8699e28cc3f1a8f1bdcb0a99de21e (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |