Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JUNE 26, 2011 FBO #3501
DOCUMENT

65 -- VASCULAR ROOM EQUIPMENT - SCI - SYRACUSE - Attachment

Notice Date
6/24/2011
 
Notice Type
Attachment
 
NAICS
339112 — Surgical and Medical Instrument Manufacturing
 
Contracting Office
VISN 2 NCA (2-90);CONTRACTING OFFICER;Department of Veterans Affairs Syracuse;1304 BUCKLEY RD, SUITE C102;Syracuse NY 13212
 
ZIP Code
13212
 
Solicitation Number
VA52811RP0223
 
Response Due
7/8/2011
 
Archive Date
9/6/2011
 
Point of Contact
STEVEN S. TOMPKINS
 
E-Mail Address
UCKLEY
 
Small Business Set-Aside
N/A
 
Description
SYSTEM REQUIREMENT FOR OR VASCULAR ROOM The system required must meet the following specifications at a minimum: "Obtain a system that guarantees flexibility to be upgraded as technology changes. "Obtain a customized installation and remote troubleshooting/service/support for the entire system. "Vascular surgery x-ray angiography system with application specific accessories. "Must have a universal ceiling-mounted C-arm angiography system with a high-resolution flat detector, 100 kW generator and x-ray tube with new flat emitter technology for excellent image quality with the functionality to optimize image impression, ability to reduce radiation exposure and DICOM compatible with remote service. "Imaging system software with digital subtraction angiography and digital acquisition technology in 1k/12-bit matrix. "Must have a radiographic system for medical applications with emphasis on surgical and diagnostic radiography, as well as keyhole vascular surgery of the chest. "Must have intervent neuro engine that bundles the basic functionality for neuro-radiological interventions. It shall include a module for optimized radiographic evaluation and diagnosis and the software applications 3d views of projection images acquired with an angiography system, cross-sectional imaging CT, in room control, guidance during interventional procedures enhanced functionality. "19" color flat screen SCD display with high luminance and extended field of view. "Stenosis measurement to determine the degree of stenosis with 3d views of projection images acquired with an angiography system. "Angiography software package that consists of DSA Angio Viewer as well as High-Speed Review for real-time display of native and subtracted angiography images. "Vascular/vessel analysis with determination of degree of stenosis, distance measurement and calibration. "Keyboard with special function keys. "3D acquisition native or subtracted (with DSA options only) rotational angiography with angle triggering, generating the image data required for 3D reconstruction. "High resolution detector 30x40, including components, dynamic flat detector for fully digital imaging chain, with integrated, removable grid. Patient safety measuring chamber for detection of the dose-area product, 3-focus high performance x-ray tube assembly, rotatable angio collimator including filter and integrated collision protection. "Runoff peripheral digital angiography with stepping and online subtraction display. "OR floor-mounted swiveling patient table with telescopic foot, floating and tiltable tabletop (in two axes); motor-driven stepping for digital peripheral angiography. Table control module, power-assisted, for obese patients no less than 500 lbs. "Table top (narrow) and mattress (thin) carbon fiber patient positioning tabletop including special-foam mattress. "Wireless foot switch for release of fluoroscopy, exposure and table brake as well a a configurable additional function. Wireless via radio communication. "DCS 4m DVI 2xBWD-19 (Live+Ref+Prp) display suspension system for three flat-screen displays with two 19" b/w flat-screen displays with blue background color with ability to expand for two additional displays. "Pre-install security systems "2nd DCS3 DVI 2xBWD-19 (Live_Ref+Prp) display suspension system for three flat-screen displays with two 19" b/w flat-screen displays with blue background color. Capability to add one additional display. "ACE cable set in equipment room for image system interface to the displays in the control room if the image system is installed in the equipment room. "C-Room DVI 2xBWD-19 (Live+Ref) -36m - two monochrome 19" flat-screen displays with blue background color. "Multimodality viewing DCS system consisting of a basic kit with video switch, optical video isolation and isolation transformer, as well as a color flat screen display with black frame and cable for installation in a DCS. "Multimodality viewing kit for connection of a color flat panel display in the examination room, including optical isolation transformer and VGA cable. "Multimodality viewing universe kit that includes an optical buffer amplifier with VGA cable and enables the image signal of any VGA-based source (SXGA 1280 x 1024 or VGA 640 x 480) to be displayed (switchable) at a display in the DCS in the examination room. "Multimodality viewing universal kit (CR) that includes an optical buffer amplifier with VGA cable and enables the image signal of any VGA-based source (SXGA 1280 x 1024 or VGA 640 x 480, e.g. Ultrasound) to be displayed (switchable) at a display in the DCS or Large Display in the examination room. The source can be easily connected and disconnected directly at the examination table. "Vessel analysis with determination of degree of stenosis, distance measurement and calibration. "Patient recovery kit manual C-arm release for easy patient recovery in case of a complete system failure. "Fluoro loop storage and review of dynamic fluoroscopic sequences. The maximum storable fluoroscopy time depends on the selected pulse rate, e.g. 17 s at 30 p/s, 34 s at 15 p/s. "Automatic stand positioning, selected reference, image and automatic reference image selection depending on the stand positioning. "DICOM HIS/RIS capability to import of patient/examination data from external RIS/HIS patient management system with DICOM MWL (modality work list). "Provision of DICOM print service for connection to a laser camera or a network printer (postscript). "Security package SW-Option/Extension for providing enhanced security features including user management and audit trail functionality. "LB radiation protection with pivot arm for shielding the lower body against scattered radiation within the examiner's moving range designed to avoid collisions with the tube during oblique projections. "Upper body radiation protection to protect the upper body against scattered radiation in the operator's environment during interventional procedures. "Interface for C-Room Operation (MA) for connecting the optional system control from the control room. "C-Room table support short rail profile for hanging control modules in the control room. "Control room emergency stop safety button capability for switching off all system functions from the control room. "Additional hand switch for radiation release and additional control functions. "Control room injector interface for controlling the contrast medium injector from the control room. "Keyboard with special keys in English - US. "Intercom system for communication between examination room and control room. "Carbon fiber patient positioning wide tabletop with straight design up to the head end for universal angiographic applications and maximum comfort for obese patients, which includes a set of body straps with three Velcro straps for securing and compressing the patient. "Wide mattress for tabletop 8 cm made of open-pore polyurethane material. "Accessory rail extension that attaches to the lateral accessory rail of the patient positioning table and enables position of the control modules on top of each other (parallel in two planes) or attaching of further accessories. "Instrument holder to be positioned at the patient table above the patient. "Instrument holder for position at the foot end of the patient table "Two arm holders for comfortable lateral arm positioning along the patient's body. "Body belt protection set consists of two belts with velcro strap used for general fixation and compression that are laid around patient and tabletop. "Two service and operational manuals and related documentation "Pre-install C-arm "Pre-install C-arm table "Initial onsite training (32 hrs.) "Follow up training (12 hrs.) "Additional onsite training (32 hrs.) "Government training class (T&L not included) "Injector Rack Mt., Table BR HD "Pedestal for injector head, mark V provis "Blue anti-fatigue floor mat for hospital "Standard Rigging zee SP "Offset initial training (32 hrs.) "One complimentary biomedical tuition/training. ? REQUIRED EQUIPMENT FOR PURCHASE: Visum LED2 Surgical Lights "The Visum LED2 is capable of complete platform integration that meets the requirements of a unified solution (with voice activated device control, integration router, and remote diagnostic support) to provide full optimization of product features and functionality. "SORN provides remote diagnostics & support of Visum LED2 surgical lights, integration, and compatible equipment attached to the lights. "LED light with spot size of 8.5 - 12.0", Ra >90, R9 85 +- 10% with a lifetime of 20,000+ hrs. "The Visum LED2 light output can be controlled from integration touch panel and through voice activated device control "The Visum LED2 is Ceiling mount "The Visum LED2 provides Cool light emission "The Visum LED2 outputs a LUX (luminous flux density) rating of 160,000 which is the maximum allowed under the FDA regulations. "The Visum LED2 has an adjustable field diameter that ranges from 7 to over 12 inches "The Visum LED2 has a depth of field that measures up to 43 inches "The Visum LED2 contains a unique reflector shield design that provides a 39 degree continuous column of light; allowing the surgical staff to move the light continuously throughout the procedure without having to re-focus the lights. "Shadow resolution: The design of the Visum LED2 light utilizes every inch of the light head casting separate beams of light, providing a greater surface of light projection to the surgical field reducing shadows to the absolute minimum. "The Visum LED2 light head is made of Aluminum Alloy. "The Visum LED2 provides pure white light with an Ra value of >90 and an R9 value of 85 plus or minus 10% "The Visum LED2 lens covers made with a safety glass that will not yellow with age "The Visum LED2 has a bulb life of at least 30,000 hours "The Visum LED2 has 360 degree rotation "Visum LED2 lights are UL certified and FDA approved "The Visum LEDs lights utilize only 126 watts. "To reduced repair downtime: All critical Visum LED2 components are housed in a centrally located power supply box, instead of inside the light or above the ceiling. The box is extremely easy to exchange for repair with no need to break down the light or access the ceiling, reducing repair costs and down time.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/SyVAMC670/SyVAMC670/VA52811RP0223/listing.html)
 
Document(s)
Attachment
 
File Name: VA-528-11-RP-0223 VA-528-11-RP-0223_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=212789&FileName=VA-528-11-RP-0223-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=212789&FileName=VA-528-11-RP-0223-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: SYRACUSE VAMC;ATTN: SCI;800 IRVING AVE;SYRACUSE, NY 13210
Zip Code: 13210
 
Record
SN02482458-W 20110626/110624235232-ba022c5980b068e409c60cd10265e567 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.