SOLICITATION NOTICE
59 -- 18 AWG Shielded Copper Cable - RFQ
- Notice Date
- 7/15/2011
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 331422
— Copper Wire (except Mechanical) Drawing
- Contracting Office
- Department of the Air Force, Pacific Air Forces, 35 CONS - Misawa, Unit 5201, Misawa AB, APO Japan, 96319-5201
- ZIP Code
- 96319-5201
- Solicitation Number
- FA5205-11-Q-JH04
- Archive Date
- 8/11/2011
- Point of Contact
- SSgt Joseph W. Hoh, Phone: 01181176773898, Yoshikatsu Nakamura, Phone: 81-176-77-3895
- E-Mail Address
-
joseph.hoh@misawa.af.mil, yoshikatsu.nakamura.jp@misawa.af.mil
(joseph.hoh@misawa.af.mil, yoshikatsu.nakamura.jp@misawa.af.mil)
- Small Business Set-Aside
- N/A
- Description
- Request for Quote (RFQ) This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. The solicitation number is FA5205-11-Q-JH04; this solicitation is a request for quotation. This solicitation document and incorporated provisions and clauses are those in effect through FAC 2005-53, DCN 20110629, and AFAC 2011-0714. This acquisition will be full and open competition; the North American Industry Classification System (NAICS) code is 331422. The business size standard is 1,000 employees. The Federal Supply Class (FSC) is 5995. The Standard Industrial Classification (SIC) is 3357. CLIN 0001: 1 Spool (1,200 Feet), 18 AWG Shielded copper cable with 27 individual conductors, gray in color. E96275-T Type: PLTC 18 AWG 90 C 300V. MINIMUM REQUIREMENTS FOR CABLE: Type: PLTS: Multiconductor, stranded, twisted pair color coded copper, shielded with drain wire providing 100% coverage. Minimum number of conductors: 27. Cable Gage: 18 AWG. Voltage: 300V. Capacitance: 30 pF/FT Nom. Insulation: 105 degrees C PVC, Minimum average insulation is.0015 in. Jacket: 90 degrees C FR PVC, sunlight resistant, thickness per UL 13 and UL 2250, footage sequentially printed. Application: (UL) Listed Power Limited Tray Cable for use in instrumentation, process control where protection from electrostatic interference is necessary. Approved for indoors, outdoors, ducts, aerially, in conduit, cable trays, direct burial up to 300 volts. PLEASE USE THE ATTACHED RFQ WHEN PROVIDING A RESPONSE. PLEASE INCLUDE ANY SHIPPING CHARGES FOR ALL CLIN'S TO THE FOLLOWING ADDRESS: Dorsey Road Warehouse 1472 Dorsey Road ATTN: LL163 (Marie Cluster), Internal Delivery; Misawa AB Hanover, MD 21076 Award shall be made in the aggregate, all or none. EVALUATION CRITERIA: Evaluation of offers will be completed in accordance with FAR 13.106-2. The Government will award a contract resulting from this solicitation to the responsible offeror whose offer conforms to the solicitation and represents the best value to the Government, price and other factors considered. The following factors shall be used to evaluate offers: A) TECHNICAL ACCEPTABILITY - All offers must meet the requirements as set forth in this combined synopsis/solicitation. B) PRICE - The price proposed by the offeror will be included as part of the evaluation. The following provisions and/or clauses apply to this acquisition. Offerors must comply with all instructions contained in FAR 52.212-1 Instructions to Offerors -- Commercial Items. FAR 52.212-3 Alt I Offeror Representations and Certifications - Commercial Items. FAR 52.212-4 Contract Terms and Conditions - Commercial Items. FAR 52.212-5 (Dev) Contract Terms and Condition Required to Implement Statues or Executive Orders-Commercial Items (Deviation). FAR 52.222-19 Child Labor - Cooperation with Authorities and Remedies. FAR 52.222-21 Prohibition of Segregated Facilities. FAR 52.222-26 Equal Opportunity. FAR 52.222-50 Combating Trafficking in Persons. FAR 52.223-18 Contractor Policy to Ban Text Messaging While Driving. FAR 52.225-13 Restrictions on Certain Foreign Purchases. FAR 52.232-33 Payment by Electronic Funds Transfer - Central Contractor Registration. DFARS 252.203-7000 Requirements Relating to Compensation of Former DoD Officials. DFARS 252.212-7001 (Dev) Contract Terms and Conditions Required to Implement Statutes or Executive Orders Applicable to Defense Acquisitions of Commercial Items. DFARS 252.232-7003 Electronic Submission of Payment Requests and Receiving Reports. DFARS 252.232-7010 Levis on Contract Payments. Clauses may be accessed electronically in full text through http://farsite.hill.af.mil. Contractors must be actively registered with the Central Contractor Registration (CCR) at http://www.ccr.gov, at Wide Area Work Flow (WAWF) at http://wawf.eb.mil, and at Online Representations and Certifications Application (ORCA) at http://orca.bpn.gov. Please send any response to joseph.hoh@misawa.af.mil NO LATER THAN 27 JULY 2011, 4:00 PM, JST. Point of contact is Joseph Hoh, SSgt, Contract Specialist, telephone 011-81-176-77-3898, joseph.hoh@misawa.af.mil. Alternate POC is Yoshikatsu Nakamura, Contracting Officer, telephone 011-81-176-77-3898, yoshikatsu.nakamura.jp@lajes.af.mil.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/PAF/35CONS/FA5205-11-Q-JH04/listing.html)
- Place of Performance
- Address: Dorsey Road Warehouse, 1472 Dorsey Road, ATTN: LL163 (Marie Cluster), Internal Delivery: Misawa AB, Hanover, Maryland, 21076, United States
- Zip Code: 21076
- Zip Code: 21076
- Record
- SN02501278-W 20110717/110716000245-36e70769c4337019928228ededf0da60 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |