DOCUMENT

Y -- Replace Emergency Generator B47 - Attachment

Notice Date
8/8/2011
 
Notice Type
Attachment
 
NAICS
238210 — Electrical Contractors and Other Wiring Installation Contractors
 
Contracting Office
Department of Veterans Affairs;VISN 6 Centralized Acquisition Service;1100 Tunnel Road;Asheville NC 28805
 
ZIP Code
28805
 
Solicitation Number
VA24611IB0062
 
Archive Date
11/6/2011
 
Point of Contact
Denise O'Brien
 
E-Mail Address
Contract Specialist
(denise.obrien2@va.gov)
 
Small Business Set-Aside
Service-Disabled Veteran-Owned Small Business
 
Description
The Charles George VAMC, Asheville, NC is pre-soliciting certified Service Disabled Veteran Owned Small Business to replace Emergency Generator in main Bldg 47. Work includes (but is not limited to) installing a new 1250KW diesel emergency generator set to include fuel line, fuel pump and day tank. Work includes installing associated exhaust thru existing roof with roof repair. Electrical work include new paralleling gear and connecting to the existing buss duct feeder. The existing 1000 KW generator is to be demolished and removed from VA property. New generator will be installed in a vacant space next to the 1250KW generator feeding the clinical additions and is to be installed and up and running prior to demolition of the existing 1000KW generator. New generator site will require block/brick wall sections for access to area and crane to place generator. All work shall be in accordance with construction drawings and specifications. The NACIS code for this procurement is 238210 with a small business size standard of $14M. All work shall be completed within 120 calendar days after date of receipt of notice to proceed. This includes final inspection and clean-up. The magnitude of this construction is between $250,000.00 and $500,000.00. Expect the solicitation to be posted with uploaded drawings and specification on/or about 23 August 2011. No hard copies will provided. Pre-Bid/Walk through is scheduled for on/about 30 August 2011. Bid opening will be on/or about 23 Sep 2011. Firms MUST be registered at Central Contractor Registry (CCR) and at Vet Biz and Online Representations and Certifications must be completed by each bidder prior to the bid opening.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/AsVAMC/VAMCCO80220/VA24611IB0062/listing.html)
 
Document(s)
Attachment
 
File Name: VA-246-11-IB-0062 VA-246-11-IB-0062.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=229400&FileName=VA-246-11-IB-0062-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=229400&FileName=VA-246-11-IB-0062-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Charles George VAMC;1100 Tunnel Rd;Asheville NC
Zip Code: 28805
 
Record
SN02525130-W 20110810/110808234915-76cc8411b420b64af2815dca77809873 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.