SOLICITATION NOTICE
59 -- Purchase three (3) Current Transformer Saturation, Ratio and Polarity Test Sets
- Notice Date
- 8/12/2011
- Notice Type
- Combined Synopsis/Solicitation
- NAICS
- 334515
— Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals
- Contracting Office
- USACE HEC, Ft. Belvoir, ATTN: CEHEC-CT, 7701 Telegraph Road, Alexandria, VA 22315-3860
- ZIP Code
- 22315-3860
- Solicitation Number
- W912HQ-11-T-0026
- Response Due
- 8/22/2011
- Archive Date
- 10/21/2011
- Point of Contact
- Sarah R Wiley, 703-428-7407
- E-Mail Address
-
USACE HEC, Ft. Belvoir
(sarah.r.wiley@usace.army.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. Reference number is W912HQ-11-T-0026 is issued as a Request for Quote (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-53. The closing date of this synopsis/solicitation is 22 Aug 2011 at 4:30 P.M. EDST. The requirement is set aside for small business and the associated NAICS code is 334515. Contract Line Items: Line Item 0001 - Megger MCT1600B Test Set Description: Three (3) Megger MCT1600B Current Transformer Saturation, Ratio and Polarity Test Sets are needed. Delivery Information: The items shall be shipped no later than 15 days after the date of contract award. Delivery shall be made to: United States Army Prime Power School ATTN: Milton Chisolm BLDG. 12630 FLW 28 Fort Leonard Wood, MO 65473 The Government will award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous to the Government, price and other factors considered. Clauses may be accessed electronically in full text through http://farsite.hill.af.mil. Contractors must be actively registered with the Central Contractor Registration (CCR) at http://www.ccr.gov and at Online Representations and Certifications Application (ORCA) at http://orca.bpn.gov. The following provisions apply: FAR 52.212-1 Instructions to Offerors-Commercial FAR 52.212-3 Offerors Representation and Certifications Commercial Item or complete electronic annual representations and certifications at http://orca.bpn.gov FAR 52.212-4 Contract Terms and Condition-Commercial Items FAR 52.212-5 Contract Terms and Conditions Required to Implement Statutes or Executive Orders-Commercial Item are incorporated by reference, however, for paragraphs (b) and (c) the following clauses apply: FAR 52.204-10 Reporting Executive Compensation FAR 52.219-6 Notice of Small Business Set-Aside; FAR 52.219-28 Post Award Small Business Program Representation FAR 52.222-3 Convict Labor FAR 52.222-19 Child Labor FAR 52.222-21 Prohibition of Segregated Facilities; FAR 52.222-26 Equal Opportunity; FAR 52.222-36 Affirmative Action for Workers with Disabilities; FAR 52.223-18 Contractor Policy to Ban Text Messaging while Driving FAR 52.225-1, Buy American Act - Supplies; Offerors are reminded that the Buy American Act restricts the purchase of supplies that are not domestic end products. FAR 52.232-33 Payment by Electric Funds Transfer -- CCR FAR 52.252-1 Solicitation Provisions Incorporated by Reference DFARS 252.212-7001 Contract Terms and Conditions Required to Implement Statutes or Executive Orders Applicable to Defense Acquisitions of Commercial Items with following clauses that apply: 252.203-7000 Requirements Relating to Compensation of Former DoD Officials; 252.232-7003 Electronic Submission of Payment Requests and Receiving Reports; & 252.247-7023 Transportation of Supplies by Sea - Alt III Due Date: The due date for the delivery of a response to this combined synopsis/solicitation is on or before 04:30 P.M., EDST, Monday, 22 August 2011 to sarah.r.wiley@usace.army.mil or fax to Attn: Sarah Wiley 703-428-8181. Point of Contact: Sarah Wiley, Contract Specialist Phone: 703-428-7407 Fax: 703-428-8181 Email: sarah.r.wiley@usace.army.mil Specifications for three (3) Automatic Current Transformer Saturation, Ratio and Polarity Test Sets Background: The United States Army Prime Power School (USAPPS) trains U.S. Army and Navy personnel on the proper utilization of Current Saturation Transformer Testing Technology to evaluate the condition of electrical current transformers and potential transformers and associated protective relay distribution equipment for their supported customers. Scope: USAPPS has a requirement for three (3) MEGGER MCT1600B test sets to support the Transformer Course taught at the Prime Power School. USAPPS is tasked to provide industry standard training because of the hazardous environment associated with medium voltage power generation and distribution. This requirement requires the school to continuously evaluate the curriculum for relevance and the best product available to accomplish this objective. The MEGGER MCT1600B specifications meet the desired training level and projected training level of the ALC course for 12P MOS (students), and the U.S. Army Corps of Engineers requirements for each 12PS3 soldier to understand Transformer Saturation theory concepts and usage while performing their protective transformer relay testing reports. Deliverables and Technical Specifications: The contractor shall supply three (3) MEGGER MCT1600B and associated operation software in accordance with the technical specifications listed below. a. Input: 100 to 265 V, 1 phase, 50 or 60 hz, 15A max draw b. Output:(continuously variable in four ranges: 1) 0-40 Volts at 2.0 Amps max (5 minute on 15 minute off) 2) 0-40 Volts at 5 Amps max for burden test 3) 0-160 Volts at 2.0 Amps max(5 minute on 15 minutes off) 4) 0-800 Volts at 1.5 Amps max(3 minutes on 15 minutes off) 5) 0-1600 Volts at 1.0 Amps max(3 minutes on 15 minutes off) c. Instrumentation: Voltmeters, Output: 1) 4 digit, auto ranging d. Resolution: 0.0000 to 1.9999/19.999/199.99/1999.9 e. Ranges 0-40/160/800/1600 Volts f. Accuracy: 0.5% of reading and 0.5% range typical 1% of reading and 1 Volt maximum g. Instrumentation: Voltmeters, Input: 4 digit, auto ranging h. Ranges: 0-2/600 i. Resolution: 0.0000 to 1.9999/19.999/199.99/600 Volts j. Accuracy: 2 Volt range 0.5% of reading, and 0.25% range; 600 Volt range 0.5% of reading, and 0.5% range k. Ammeter: 4 digit, auto-ranging l. Range 0.0000 to 1.0000A/5.000 m. Accuracy 0.85% of reading and 1 LSD n. Phase Angle: 3 digits o. Range: 0-360 degrees p. Accuracy: 1 degree at normal voltage ratio q. Range: 0.8 to 5000 r. Accuracy 0.4% typical, 0.8% maximum s. Ratio Test Frequency: 50/60Hz test set t. Winding Resistance: 1) Measuring Range:.01 ohms to 99.9 ohms 2) Accuracy: <99.9 ohms 3% of reading 2 digits u. Measuring Range:.01 ohms to 99.9 ohms v. Accuracy: <99.9 ohms 3% of reading 2 digits w. Insulation test: 1) Test Voltage: 1000 VDC, 500 VDC 2) Measuring Range 10k ohms to 999M ohms x. Short Circuit Current: 1.5mA nominal y. Test Current on Load: 1mA at min. pass b values of insulation (as specified in BS7671, HD 384 and IEC 364) z. Communication Interfaces: USB/Ethernet aa. Environment: ab. Operating: -10 degrees C to 40 degrees C ac. Storage: -30 degrees C to 70 degrees C ad. Standards: IEC 61010, CSA 22.2, CE ae. Weighting no more than 48 pounds af. Enclosure: the unit housing in a rugged enclosure suitable for use in outdoor environment
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA72/W912HQ-11-T-0026/listing.html)
- Place of Performance
- Address: USACE HEC, Ft. Belvoir ATTN: CEHEC-CT, 7701 Telegraph Road Alexandria VA
- Zip Code: 22315-3860
- Zip Code: 22315-3860
- Record
- SN02532299-W 20110814/110812235455-ccfea7a20c8043456509b77afe546d05 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |