59 -- seeking new lighting technologies to retrofit many existing DoD perimeter security lighting systems, in order to provide appropriate lighting, economic energy benefits, and reduced life cycle cost - Attachment

Notice Date
9/14/2011
 
Notice Type
Attachment
 
NAICS
541330 — Engineering Services
 
Contracting Office
N62583 SPECIALTY CENTER ACQUISITIONS NAVFAC 1100 23rd Ave Bldg 1100 Port Hueneme, CA
 
Solicitation Number
N6258311C0662
 
Response Due
10/15/2011
 
Archive Date
10/15/2011
 
Point of Contact
Richard Lee -
 
E-Mail Address
<!--
 
Small Business Set-Aside
N/A
 
Description
The Naval Facilities Engineering Command Engineering Services Center (NAVFAC ESC), Port Hueneme, CA is seeking new commerciallly available lighting technologies to retrofit many existing DoD perimeter security lighting systems, in order to provide appropriate lighting, economic energy benefits, and reduced life cycle cost. It is a market survey to identify commercially available security lighting technologies using induction, LED, or plasma at military installations under extreme climate conditions, where electrical power is provided by 380 volt 50 hertz generators. Security lighting provides illumination during periods of darkness or in areas of low visibility to aid security forces in the detection, assessment, and interdiction of aggressors. Controlled lighting is best used when it is necessary to limit the width of the lighted strip along the perimeter due to adjoining property. The guidance for the design of exterior lighting systems and controls is provided by the Unified Facilities Criteria (UFC), http://www.wbdg.org/ccb/DOD/UFC/ufc_3_530_01.pdf. This UFC meets the current Illuminating Engineering Society of North America ™s (IESNA) standard of practice and addresses general lighting requirements for Department of Defense (DoD) facilities. The specific criteria and design for perimeter security lighting are provided in UFC Chapter 6 “ Security Lighting, Table 6-1 of page 85, and Chapter 8 “ Exterior Applications, Table 8-1 on page 176. Table 6-1 summarizes the minimum horizontal and vertical illuminance levels for typical facility applications. The inner clear zone noted in the table refers to the area along a perimeter fence line within the facility or installation. The isolation zone refers to the area between a double fence line. The outer clear zone describes the area along the perimeter fence on the outside of the protected area. Isolation and clear zones are typically 30 feet (9.1 meters) in width. It is important to note however that overlighting can cause just as many visibility problems as underlighting. In typical applications, the maximum light levels should not be more than double the recommended average value.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/NAVFAC/N47408/N6258311C0662/listing.html)
 
Document(s)
Attachment
 
File Name: N6258311C0662_SourcesSought_Lighting_technologies.pdf (https://www.neco.navy.mil/synopsis_file/N6258311C0662_SourcesSought_Lighting_technologies.pdf)
Link: https://www.neco.navy.mil/synopsis_file/N6258311C0662_SourcesSought_Lighting_technologies.pdf

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN02576820-W 20110916/110915000806-f100e41406d68092298278ee92127a59 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.