SOURCES SOUGHT
J -- USCGC 270 WMEC CUTTERS SEWAGE CONTROLLER UPGRADES
- Notice Date
- 10/4/2011
- Notice Type
- Sources Sought
- NAICS
- 336611
— Ship Building and Repairing
- Contracting Office
- Department of Homeland Security, United States Coast Guard (USCG), USCG Surface Forces Logistics Center (SFLC) Procurement Branch 1, 300 East Main Street, Suite 600, Norfolk, Virginia, 23510-9102, United States
- ZIP Code
- 23510-9102
- Solicitation Number
- SEWAGE-CONTROLLER-UPGRADE
- Archive Date
- 10/4/2012
- Point of Contact
- Arlene V Woodley, Phone: (757) 628-4645
- E-Mail Address
-
Arlene.V.Woodley@uscg.mil
(Arlene.V.Woodley@uscg.mil)
- Small Business Set-Aside
- N/A
- Description
- The U.S. Coast Guard is considering whether or not to set aside an acquisition for HUBZone concerns, or Service-Disabled Veteran-Owned, or Small Business concerns. This acquisition is to establish a two year Indefinite Delivery Contract; Base and One (1) option year. The small business size standard is 1,000 employees. The NAICS Code is 336611. The scope of the acquisition is as follows: 1. Sewage Control System, Upgrade 2. Sewage Holding Tanks, Clean and Inspect (A-Class) 3. Sewage Holding Tanks, Clean and Inspect (B-Class) 4. Grey Water Holding Tanks, Clean and Inspect (A-Class) 5. Grey Water Holding Tanks, Clean and Inspect (B-Class) All welding and brazing shall be accomplished by trained welders who have been certified by the applicable regulatory code performance qualification procedures. All work will be performed at the vessels home pier. These vessels and home piers are as follows: Portsmouth, VA : (CGC BEAR, CGC FORWARD, CGC HARRIET LANE, CGC LEGARE, CGC NORTHLAND, CGC TAMPA) Key West, FL: (CGC MOHAWK, CGC THETIS) Boston, MA: (CGC ESCANABA, CGC SENECA, CGC SPENCER) Kittery, ME: (CGC CAMPBELL, CGC TOHOMA) The performance period is 12 days, with a start date on or about 23 April 2012. In accordance with FAR 19.1305 and FAR 19.1405, if your firm is and intends to submit an offer on this acquisition, please include the following : (a) positive statement of your intent to submit a quotation for this procurement as a prime contractor; (b) evidence of experience in work similar in type and scope to include contract numbers, project title, dollar amount, points of contact and phone numbers; (c) Past Performance references with points of contacts and pone numbers. At least two (2) references are requested, but more are desirable. Your response is required by October 12, 2011. All of the above must be submitted in sufficient detail for a decision to be made on a HUBZone Set-Aside or Service-Disabled Veteran-Owned Set-Aside or Small Business Set-Aside. Failure to submit information requested may result in an unrestricted acquisition. A decision on whether this will be pursued as HUBZone Set-Aside, Serviced-Disabled Veteran-Owned Set-Aside, Small Business Set-Aside, or on an unrestricted basis will be posted on FEDBizOPs website at http://www.eps.gov. Questions may be referred to Arlene Woodley via e-mail: arlene.v.woodley@uscg.mil or (757) 628-4645.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DHS/USCG/COUSCGMLCA/SEWAGE-CONTROLLER-UPGRADE/listing.html)
- Record
- SN02601510-W 20111006/111004234357-15ff37b27a20d0e3aed92ebd484d00be (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |