Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF OCTOBER 29, 2011 FBO #3626
DOCUMENT

65 -- IV Start Kit with and without Gloves - Attachment

Notice Date
10/27/2011
 
Notice Type
Attachment
 
NAICS
339113 — Surgical Appliance and Supplies Manufacturing
 
Contracting Office
VA National Acquisition Center - Department of Veterans Affairs National Acquisition Center
 
Solicitation Number
VA797N12I0007
 
Response Due
11/14/2011
 
Archive Date
1/13/2012
 
Point of Contact
Glennis Haynes
 
E-Mail Address
786-7627<br
 
Small Business Set-Aside
N/A
 
Description
VA-797-N-12-I-2007 REQUEST FOR INFORMATION (RFI) FOR IV START KIT RFI closes, 3:00 pm Central Standard Time The Department of Veterans Affairs (VA) National Acquisition Center (NAC) intends to issue a Request for Quotation (RFQ) for IV Start Kit with and without Gloves. VA National Acquisition Center (NAC) wishes to learn if there are customary commercial practices in the market place regarding the specifications and packaging of IV Start Kit items. (Please see the requirements grids below). This is an effort to ensure the specifications are not overly restrictive or unreasonable. Please submit any suggestions, questions, comments on specifications; and/or information, including product literature/brochures describing your firm's ability interest to provide these items. Please submit responses to the Contracting Officer listed below. This is not the RFQ. Glennis Haynes, Contracting Officer VA National Acquisition Center (001AL-A2-3c-MS) First Avenue, 1 block North of Cermak Road P.O. Box 76, Building 37 Hines, IL 60141 Call Glennis Haynes at (708) 786-5136. Glennis.Haynes@va.gov Product Line: IV Start Kit with Gloves LENGTH OF CONTRACT: 5 Years Minimum Technical Requirements (MTR)Method of Evaluation: MTR 1SterileLiterature Review or Physical Inspection MTR 2Packaged for sterile presentation, can be opened without contamination of product.Physical Inspection and Simulated Use MTR 3All contents of the kit are latex freeLiterature Review or Physical Inspection MTR 4List of contents in or on package must be visible.Physical Inspection MTR 5Tourniquet must be 3/4" to 1-1/4" inches wide.Literature Review or Physical Inspection MTR 6Tourniquet must be 17 - 19 inches long.Literature Review or Physical Inspection MTR 7One sterile applicator Chlorhexidine Gluconate 2% (minimum.67ml but no more than 1.5ml)Literature Review or Physical Inspection MTR 8Sterile, 2 each 2 x 2 inch, minimum 4 ply gauzeLiterature Review or Physical Inspection MTR 9Transparent Film Dressing, minimum of 3 x 3" inch maximum 3 x 4" inches Literature Review or Physical Inspection MTR 10Transparent tape, minimum of.75 inch to 1 inch wide, 18 inch rollLiterature Review or Physical Inspection MTR 11Universal size Latex-free gloves, powder free, cuffedLiterature Review or Physical Inspection MTR 12Label, minimum 2 inch x 1 inch, with space for date, time, initials, gauge of needleLiterature Review or Physical Inspection MTR 13Mechanical Stabalization device (not tape or foam)Literature Review or Physical Inspection Intended Use: Used to antiseptically prepare and secure peripheral IV catheter. Product Line: IV Start Kit without Gloves LENGTH OF CONTRACT: 5 Years Minimum Technical Requirements (MTR)Method of Evaluation: MTR 1SterileLiterature Review or Physical Inspection MTR 2Packaged for sterile presentation, can be opened without contamination of product.Physical Inspection and Simulated Use MTR 3All contents of the kit are latex freeLiterature Review or Physical Inspection MTR 4List of contents in or on package must be visible.Physical Inspection MTR 5Tourniquet must be 3/4" to 1-1/4" inches wide.Literature Review or Physical Inspection MTR 6Tourniquet must be 17 - 19 inches long.Literature Review or Physical Inspection MTR 7One sterile applicator Chlorhexidine Gluconate 2% (minimum.67ml but no more than 1.5ml)Literature Review or Physical Inspection MTR 8Sterile, 2 each 2 x 2 inch, minimum 4 ply gauzeLiterature Review or Physical Inspection MTR 9Transparent Film Dressing, minimum of 3 x 3" inch maximum 3 x 4" inches Literature Review or Physical Inspection MTR 10Transparent tape, minimum of.75 inch to 1 inch wide, 18 inch rollLiterature Review or Physical Inspection MTR 11Label, minimum 2 inch x 1 inch, with space for date, time, initials, gauge of needleLiterature Review or Physical Inspection MTR 12Mechanical Stabalization device (not tape or foam)Literature Review or Physical Inspection Comments Acceptable/Unacceptable Recommendation: Intended Use: Used to antiseptically prepare and secure peripheral IV catheter.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/VANAC/VANAC/VA797N12I0007/listing.html)
 
Document(s)
Attachment
 
File Name: VA797N-12-I-0007 VA797N-12-I-0007_1.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=268932&FileName=VA797N-12-I-0007-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=268932&FileName=VA797N-12-I-0007-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Record
SN02614172-W 20111029/111027234623-f87e868e36c74e44e6b26f27b4b76dd6 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.