SPECIAL NOTICE
Z -- Install Gas Infra-Red Radiant Heaters
- Notice Date
- 11/3/2011
- Notice Type
- Special Notice
- NAICS
- 238220
— Plumbing, Heating, and Air-Conditioning Contractors
- Contracting Office
- USACE District, Sacramento, 1325 J. Street, Sacramento, CA 95814
- ZIP Code
- 95814
- Solicitation Number
- W9123812R0004
- Archive Date
- 11/2/2012
- Point of Contact
- Eunice A. Haynes, 9165577162
- E-Mail Address
-
USACE District, Sacramento
(eunice.a.haynes@usace.army.mil)
- Small Business Set-Aside
- N/A
- Description
- Installation: Contractor shall provide and install four (4) New, Vent Free type, high Intensity Infra-Red heaters utilizing propane gas, each rated a minimum of 50,000 BTU/hr. Heater style shall be surface combustion type. Reflector shape shall be parabolic. Heaters shall be equipped with burner utilizing propane gas and each heater shall be provided with a gas pressure regulator that will satisfactorily limit the main gas burner supply pressure for indoor use. Heaters shall have an intermittent or interrupted electrically-ignited pilot or a direct electric ignition system. Space thermostats shall have 3 degrees Fahrenheit differential and set point range of 50 to 65 degrees Fahrenheit and shall be set at 65 degrees Fahrenheit. Thermostats shall control the burner and thermostats shall be mounted to the closest column that is accessible. Install a mechanical twist timer for each thermostat and the timer shall be manually set, mechanically driven timer, or electronic timer, without a "hold" feature. Time intervals shall be selectable for up to 2 hours of operation and shall expire unless reset. Relocate and Dispose: Contractor is to disconnect, remove and dispose of existing 500-gallon propane tank located on the southeast corner of Building 208, including piping to the building. Disconnect and relocate existing 1000-gallon propane tank located southeast of Building 286 (MHE area) to south of Building 208. Prior to relocation, pressure test and inspect tank. Contractor shall secure and reuse the 500-gallon tank existing foundation supports as required for the re-located 1000-gallon propane tank and replace pressure regulator and valve. It is the contractor's responsibility to re-enforce the foundation supports as necessary. Contractor shall verify existing conditions and dimensions. Slated time for completion shall include final clean-up of the premises.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/COE/DACA05/W9123812R0004/listing.html)
- Record
- SN02617263-W 20111105/111103233852-66aebaf5dca78ec4df838312943a2d1f (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |