SPECIAL NOTICE
66 -- Trace Level CO & NO-NOy Analyzers and ZAG
- Notice Date
- 11/8/2011
- Notice Type
- Special Notice
- NAICS
- 334516
— Analytical Laboratory Instrument Manufacturing
- Contracting Office
- RTPPODUS Environmental Protection Agency109 T.W. Alexander DriveMail Code: E105-02Research Triangle ParkNC27709USA
- ZIP Code
- 00000
- Solicitation Number
- SOL-NC-12-00016
- Point of Contact
- Rodney-Daryl Jones
- E-Mail Address
-
Jones.Rodney-Daryl@epa.gov
(Jones.Rodney-Daryl@epa.gov)
- Small Business Set-Aside
- N/A
- Description
- NAICS Code: 334516 The U.S. Environmental Protection Agency (EPA) Office of Air Quality Planning and Standards (OAQPS), under the authority of the Federal Acquisition Rules (FAR) Subpart 8.4, Federal Supply Schedules, intends to issue a sole source purchase order to Advanced Pollution Instrumentation for the purchase of two ambient Air Trace Level Carbon Monoxide (CO) analyzers, one trace level NO-NOy Analyzer, and two Zero Air Generators (ZAGs). Scope and Capabilities: The objective is to obtain two ZAGs, two CO analyzers, and one NO-NOy analyzer for use in the EPA Research Triangle Park (RTP) laboratory and in regional laboratories. These systems are used for independent ambient air monitoring gas analyzer audits in accordance with 40 CFR part 58, Appendix A, section 2.4 and 3.2.2. The ZAG systems must meet the following specifications:1.Internal, long-life, oil-less piston pump, with automatic pump control based on flow demand;2.Regenerative heatless dryer, with lifetime of greater than 5 years; independent of inlet dew point;3.Rack mount;4.Scrubbers for SO2, NO, NO2, O3, plus HC and CO option scrubbers; and5.30 SLPM output. The CO Analyzers must meet the following specifications:1.EPA-designated Reference or Equivalent Method (see EPA-website at www.epa.gov/ttn/amtic/criteria.html) RFCA-1093-093;2.Enhanced Gas filter correlation ambient trace level continuous analyzer with a minimum concentration range of 0-100 ppb and a maximum range of 1-100 ppm and an adjustable averaging time;3.Thermally stabilized heated reaction chamber and a stabilized flow system using capillary technology;4.Lower detectable limit of < 20 ppb;5.Ability for the monitor to perform an automatic zero;6.Zero drift of < 20 ppb/24 hours;7.Span drift < 0.5% of reading/24 hours above 5 ppm;8.Lag time of 10 seconds;9.Rise and fall time of < 60 seconds to95%;10.Linearity of 1% of full scale;11.Precision of 0.5% of reading;12.Sample flow rate of 1800 cm?/min ?20%;13.Rack mount; 14.Power requirements of 100V-120v and 50/60 Hz;15.Analog output ranges of 10V, 5V, 1V, 0, or 1V;16. 2 RS 232 ports; 17.2 USB device ports;18.Opto-isolated digital outputs;19.Opto-isolated digital inputs;20.Analog outputs;21.Self-aligning optics, heated multi-pass optical bench, and vibration protection;22.Electronic diagnostic transducer, dedicated communication processor, remote performance diagnostics;23.Spare parts package;24.Internal pumps;25.Operating temperature range of 5-40?C;26.Dimension of 7? x 17? x 23.5? (178 x 432 x 597 mm);27.50 lbs or less; and28.Full DCHP implementation via Ethernet ports on the analyzer. NO-NOy analyzer specifications:1.US EPA Reference or Equivalent Method Designation for NO2/NOy, RFNA-1194-099;2.Remotely mounted molybdenum converter with temperature controller in an enclosure;3.Converter Temperature, nominally controlled to between 315 and 325?C;4.Tube/Electrical Cable Assembly, up to 50 feet max. length; 5.Converter Efficiency: > 96%, NO2; 6.Teflon fittings between the converter inlet and the converter; 7.0-100 ppb concentration range (0-50, 0-200 ppb also available), averaging time 120 seconds;8.Measurement units: ppb, ?g/m? 9.Linearity: 1% OF full scale;10.24 Hour Span Drift: ? 1%full scale, or < 0.5% of reading; 11.Lower Detectable Limit = 0.050 ppb;12.Zero Noise: < 25 ppt RMS; 13.24 hour Zero Drift: < 0.1ppb;14.Lag time: 20 seconds;15.Rise and fall time: < 50 seconds to 95%;16.Precision: 0.5% of reading above 5 ppb;17.Ethernet port;18.Flash memory port;19.Opto-isolated digital outputs and inputs;20.Serial I/O Com Ports, at least 2 for RS232, or RS232 or 485;21.Analog Output Ranges: 100 millivolts; and 1, 5, and 10 volts; and 4-20 milliAmps;22.Recorder Offset: ?10%;23.Dimensions: 7? x 17? x 23.5?; 24.Weight: Analyzer, 40 Lbs; Converter, 21 Lbs; 25.Sample Flow Rate:1 LPM; 26.Bypass Flow Rate: 800cc/min;27.Cal. Gas flow rate: 4 lpm; and28.Extended service warranty. NO SOLICITATION OR REQUEST FOR QUOTE IS AVAILABLE. Teledyne API is the only vendor providing these instruments. Notwithstanding, any firm who believes it is capable of meeting EPA's requirement as stated herein may submit a response, in writing, and it must be received within 15 calendar days of the date of this announcement. A determination not to compete the proposed purchase order based upon the responses is solely within the discretion of the Government. All questions should be directed to Bridget Findley via email to findley.bridget@epa.gov no later than 4:00 p.m. EST 15 calendar days after the date of this announcement. No telephonic inquiries will be accepted.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/EPA/OAM/CMD/SOL-NC-12-00016/listing.html)
- Record
- SN02619881-W 20111110/111108234539-fbe85a0505fbc8f899c274f07b25754c (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |