DOCUMENT
66 -- Purchase (2) Biospectrometer Systems - Attachment
- Notice Date
- 11/9/2011
- Notice Type
- Attachment
- NAICS
- 541712
— Research and Development in the Physical, Engineering, and Life Sciences (except Biotechnology)
- Contracting Office
- Department of Veterans Affairs;VA Boston Healthcare System;Contracting Officer (90C);940 Belmont Street;Brockton MA 02301
- ZIP Code
- 02301
- Solicitation Number
- VA24112Q0103
- Response Due
- 11/16/2011
- Archive Date
- 11/30/2011
- Point of Contact
- Christopher Humphrey
- E-Mail Address
-
opher.Humphrey@va.gov<br
- Small Business Set-Aside
- N/A
- Description
- The VA Boston Healthcare System (VABHS) intends to negotiate on a sole source basis pursuant to FAR 6.302-1 -- Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements with Optimum Technologies Inc., 68 West St, Southbridge, MA 01550 for (2) Biospectrometer Systems. This requirement will include the following characteristics: Product Description 1.ESS-1000 - Gen1 Single Channel BioSpectrometer System 2.ESS-2000 - Gen2 Dual Channel BioSpectrometer System Salient Characteristics 1.ESS-1000 - Gen1 Single Channel BioSpectrometer System "Detection of dysplasia's and cancers of epithelial tissues. "Apoptosis studies in cell cultures. "Measurements of subcellular components in cell suspensions. OPTICAL Number of spectrometer channels: 1 Spectral range: 200 - 850 nm Light source: Xenon flashlamp Pulse lengths: ~1 ?s Pulse repetition rate: 330 Hz Number of pulses in single train: 1 - 99 Source fiber size: 400 ?m core (larger or smaller on request) Collection fiber size: 100 ?m core (larger or smaller on request) ELECTRICAL Power requirements: 95 - 265 VAC, 50/60 Hz, 700 W max Power cord: 2m long with North American plug (other plugs and lengths available on request) COMPUTER Operating system: MS Windows XP Professional Application software installed: BMS View Languages supported: English Network adapter: Included; RJ-45 Cat 5e socket USB ports: 3 x 2.0 Type A MECHANICAL Size: 21 x 34 x 39 cm (8.5 x 13.5 x 15.2 inches) Weight: 23 lbs (10.5 kg) 2.ESS-2000 - Gen2 Dual Channel BioSpectrometer System "Detection of dysplasia's and cancers in epithelial tissues "Polarized and non-polarized detection "Enhanced immunity to ambient illumination "Flexible protocol configuration; pushbutton data acquisition OPTICAL Number of spectrometer channels: 2001 has 1 channel, 2002 has 2, 2003 has 3 Spectral range: 300 - 950 nm Light source: Xenon flashlamp Pulse lengths: ~10 - 30 ?s Pulse repetition rate: 50 Hz Number of pulses in single train: 1 - 99 Source fiber size: 400 ?m core (larger or smaller on request) Collection fiber size: 200 ?m core (larger or smaller on request) ELECTRICAL Power requirements: 95 - 265 VAC, 50/60 Hz, 200 W max Power cord: 2m long with North American plug (other plugs and lengths available on request) COMPUTER Operating system: MS Windows XP Professional Application software installed: Optical Biopsy 2.0 Languages supported: English Network adapter: Included; RJ-45 Cat 5e socket USB ports: 4 x 2.0 Type A MECHANICAL Size: 40.1 x 40.8 x 18.5 cm (15.8 x 16.1 x 7.3 inches) Weight: 30 lbs (13.6 kg) This Notice of Intent is NOT a request for competitive proposals. Parties may identify their interest, accompanied by supporting literature, to the Contracting Officer no later than November 14, 2011 by 03:00 PM. Responses should be sent to Christopher.Humphrey@va.gov. Information received will be for the purpose of determining whether or not to conduct a competitive procurement. The determination to conduct a competitive procurement based on responses to this notice is solely within the discretion of the Contracting Officer.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/BoVAMC/VAMCCO80220/VA24112Q0103/listing.html)
- Document(s)
- Attachment
- File Name: VA241-12-Q-0103 VA241-12-Q-0103.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=272333&FileName=VA241-12-Q-0103-000.docx)
- Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=272333&FileName=VA241-12-Q-0103-000.docx
- Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
- File Name: VA241-12-Q-0103 VA241-12-Q-0103.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=272333&FileName=VA241-12-Q-0103-000.docx)
- Place of Performance
- Address: Department of Veterans Affairs;VA Boston Healthcare System;150 South Huntington Ave;Jamaica Plain, MA
- Zip Code: 02130
- Zip Code: 02130
- Record
- SN02621017-W 20111111/111109235004-f03d71e652e74e929d2c3e73d4691ff4 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |