Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF NOVEMBER 11, 2011 FBO #3639
DOCUMENT

66 -- Purchase (2) Biospectrometer Systems - Attachment

Notice Date
11/9/2011
 
Notice Type
Attachment
 
NAICS
541712 — Research and Development in the Physical, Engineering, and Life Sciences (except Biotechnology)
 
Contracting Office
Department of Veterans Affairs;VA Boston Healthcare System;Contracting Officer (90C);940 Belmont Street;Brockton MA 02301
 
ZIP Code
02301
 
Solicitation Number
VA24112Q0103
 
Response Due
11/16/2011
 
Archive Date
11/30/2011
 
Point of Contact
Christopher Humphrey
 
E-Mail Address
opher.Humphrey@va.gov<br
 
Small Business Set-Aside
N/A
 
Description
The VA Boston Healthcare System (VABHS) intends to negotiate on a sole source basis pursuant to FAR 6.302-1 -- Only One Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements with Optimum Technologies Inc., 68 West St, Southbridge, MA 01550 for (2) Biospectrometer Systems. This requirement will include the following characteristics: Product Description 1.ESS-1000 - Gen1 Single Channel BioSpectrometer System 2.ESS-2000 - Gen2 Dual Channel BioSpectrometer System Salient Characteristics 1.ESS-1000 - Gen1 Single Channel BioSpectrometer System "Detection of dysplasia's and cancers of epithelial tissues. "Apoptosis studies in cell cultures. "Measurements of subcellular components in cell suspensions. OPTICAL Number of spectrometer channels: 1 Spectral range: 200 - 850 nm Light source: Xenon flashlamp Pulse lengths: ~1 ?s Pulse repetition rate: 330 Hz Number of pulses in single train: 1 - 99 Source fiber size: 400 ?m core (larger or smaller on request) Collection fiber size: 100 ?m core (larger or smaller on request) ELECTRICAL Power requirements: 95 - 265 VAC, 50/60 Hz, 700 W max Power cord: 2m long with North American plug (other plugs and lengths available on request) COMPUTER Operating system: MS Windows XP Professional Application software installed: BMS View Languages supported: English Network adapter: Included; RJ-45 Cat 5e socket USB ports: 3 x 2.0 Type A MECHANICAL Size: 21 x 34 x 39 cm (8.5 x 13.5 x 15.2 inches) Weight: 23 lbs (10.5 kg) 2.ESS-2000 - Gen2 Dual Channel BioSpectrometer System "Detection of dysplasia's and cancers in epithelial tissues "Polarized and non-polarized detection "Enhanced immunity to ambient illumination "Flexible protocol configuration; pushbutton data acquisition OPTICAL Number of spectrometer channels: 2001 has 1 channel, 2002 has 2, 2003 has 3 Spectral range: 300 - 950 nm Light source: Xenon flashlamp Pulse lengths: ~10 - 30 ?s Pulse repetition rate: 50 Hz Number of pulses in single train: 1 - 99 Source fiber size: 400 ?m core (larger or smaller on request) Collection fiber size: 200 ?m core (larger or smaller on request) ELECTRICAL Power requirements: 95 - 265 VAC, 50/60 Hz, 200 W max Power cord: 2m long with North American plug (other plugs and lengths available on request) COMPUTER Operating system: MS Windows XP Professional Application software installed: Optical Biopsy 2.0 Languages supported: English Network adapter: Included; RJ-45 Cat 5e socket USB ports: 4 x 2.0 Type A MECHANICAL Size: 40.1 x 40.8 x 18.5 cm (15.8 x 16.1 x 7.3 inches) Weight: 30 lbs (13.6 kg) This Notice of Intent is NOT a request for competitive proposals. Parties may identify their interest, accompanied by supporting literature, to the Contracting Officer no later than November 14, 2011 by 03:00 PM. Responses should be sent to Christopher.Humphrey@va.gov. Information received will be for the purpose of determining whether or not to conduct a competitive procurement. The determination to conduct a competitive procurement based on responses to this notice is solely within the discretion of the Contracting Officer.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/VA/BoVAMC/VAMCCO80220/VA24112Q0103/listing.html)
 
Document(s)
Attachment
 
File Name: VA241-12-Q-0103 VA241-12-Q-0103.docx (https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=272333&FileName=VA241-12-Q-0103-000.docx)
Link: https://www.vendorportal.ecms.va.gov/FBODocumentServer/DocumentServer.aspx?DocumentId=272333&FileName=VA241-12-Q-0103-000.docx

 
Note: If links are broken, refer to Point of Contact above or contact the FBO Help Desk at 877-472-3779.
 
Place of Performance
Address: Department of Veterans Affairs;VA Boston Healthcare System;150 South Huntington Ave;Jamaica Plain, MA
Zip Code: 02130
 
Record
SN02621017-W 20111111/111109235004-f03d71e652e74e929d2c3e73d4691ff4 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.