MODIFICATION
99 -- Cesium Ion Exchange Process Bulge
- Notice Date
- 11/18/2011
- Notice Type
- Modification/Amendment
- NAICS
- 332999
— All Other Miscellaneous Fabricated Metal Product Manufacturing
- Contracting Office
- Department of Energy, Bechtel National, Inc. (DOE Contractor), Bechtel National Inc., 2435 Stevens Center Place, Richland, Washington, 99352
- ZIP Code
- 99352
- Solicitation Number
- 24590-QL-MRA-PY33-00008
- Point of Contact
- Winifred Renz, Phone: 5093712338
- E-Mail Address
-
werenz@bechtel.com
(werenz@bechtel.com)
- Small Business Set-Aside
- N/A
- Description
- Request for Interest Form Cesium Ion Exchange Process Bulge. Document Number: 24590-QL-MRA-PY33-00008 Important to Safety? Yes Quality Level: NQA-1 Quality Surveillance: Level 3 - Full Scope Inspection Commodity Code: PY33 NAICS Code: 332999 https://eweb1.sba.gov/naics/dsp_naicssearch2.cfm Submit Interest By: December 2, 2011 PROJECT DESCRIPTION AND LOCATION The Hanford Tank Waste Treatment and Immobilization Plant (WTP) is a complex of radioactive waste treatment processing facilities designed and constructed by Bechtel for the Department of Energy (DOE). The facility will process the Hanford Site tank waste and put the waste into a stable glass form. The processed waste will be shipped to other sites for depository. The Project site is located at 200 East Area of the Hanford Site near Richland, Washington, along the Columbia River. The site elevation varies from 662 to 684 feet above mean sea level. Sand and silt exist as surface materials. Ambient temperature is (-) 23 degrees F minimum to 113 degrees F maximum, with relative humidity of 5% minimum to 100% maximum. The project design life is 40 years. SCOPE OF WORK Design and fabricate a Process Bulge. Bulges are extensions of process "Black" cells that house maintainable equipment (control valves, pumps, instruments, etc.), providing shielding for workers performing maintenance. Bulge design includes input from Buyer supplied data sheets, Project specifications, and P&IDs. Input documents dictate bounding dimensions, preliminary piping layout, schematic requirements, and required inlet/outlet locations. A seismic analysis and report meeting UBC requirements (using Buyer's location and specified inputs) is required. Piping design shall meet ASME B31.3 1996 requirements. Maintenance platforms shall meet requirements set forth in WAC 296-24 and Buyer's Project specifications. Seller is required to procure all equipment and instrumentation. Fabrication of piping shall meet ASME B31.3 1996. Piping is subject to 100% radiography for all butt-welds. Seller is required to demonstrate removal/replacement of maintainable equipment using tent or bag-in/bag-out system. EQUIPMENT AND MATERIALS REQUIRED Control valves and actuators Shielding Piping Instrumentation and controls Structural components Other equipment as needed in support of the bulge design and process CODES & STANDARDS WAC 296-24 Washington Administrative Code General Safety and Health Standards ANSI/AISC N690-94 Specification for the Design, Fabrication, and Erection of Steel Safety-Related Structures for Nuclear Facilities, as tailored in Appendix A of this specification AISC M016-1989 Manual of Steel Construction, Allowable Stress Design, Ninth Edition, as tailored in Appendix B of this specification ASME NQA-1-1989 Quality Assurance Program Requirements for Nuclear Facilities NFPA 70-1999 National Electrical Code SNT-TC-1A-1989 Society for Non-Destructive Testing ASME B31.3-1996 Process Piping as tailored in Appendix C of this specification ASME Section VIII Division 1 Boiler and Pressure Vessel Code, Rules for Construction of Pressure Vessels ASME Section VIII Division 2 Boiler and Pressure Vessel Code, Alternate Rules for Construction of Pressure Vessels ASME Y14.100 Engineering Drawing Practices ASME B30.20 Below-the-Hook Lifting Devices QA REQUIREMENTS Potential bidders should provide, in electronic format, some documentation that describes their company's Quality Assurance program. A summary, or table of contents of the program, similar evidence will be satisfactory. The information should be submitted/uploaded directly to the Supplier Registration Portal: https://supplier.bechtel.com T he successful bidder must be registered with Bechtel (https://supplier.bechtel.com) and shall have and maintain a documented quality assurance program that complies with the applicable WTP requirements including, but not limited to, 10 CFR 830, DOE Order 414.1, ASME NQA-1. The bidder's Quality Assurance Program must meet the specific requirements of the Material Requisition. The bidder must have the ability to demonstrate satisfactory implementation of their Quality Assurance Program to be considered for an award. In order to expedite the qualification process, potential bidders are encouraged to provide a controlled copy of their Quality Assurance Program (include the "Package Ref." - Document Number) to BNI Supplier Qualification, if controlled copy was not previously submitted and evaluated by BNI Supplier Qualification. The preferred method is to submit in electronic format via e-mail to: mssendr@bechtel.com -or- Hard copies (include the "Package Ref." - Document Number) may be submitted to: Bechtel National, Incorporated Attn: Supplier Matt Szendre MS 12-2A 2435 Stevens Center Place Richland, WA 99354 COMMERCIAL\TECHNICAL REQUIREMENTS Bechtel Procurement is responsible for collection, evaluation, and internal publication of Supplier/Subcontractor information through our project's pre-qualification program. In addition to the information requested above, Bechtel requires you to register your company at the Supplier and Contractor Portal at: https://supplier.bechtel.com Prior to being considered on any Bidders List you must go to the Qualification Process on this web site to complete the required forms for this opportunity. All information provided shall be strictly confidential. QUESTIONNAIRE Potential offeror shall submit their interest in this opportunity via e-mail using the " Submit Interest " link provided on the Two Year Forecast Report, which provides an outlined email including, but not limited to the bulleted items below, and is appropriately addressed to our central mailbox and to the buyer. Each interest email should include: •§ Dun and Bradstreet #: •§ Company Name: •§ Company Address: •§ Contact Phone #: •§ Contact Fax #: •§ Contact Person: •§ E-mail Address: Note: The wtpacqui@bechtel.com e-mail address is a document file address and is not an actual person. Bechtel personnel will access this address to see who has registered, but since it is not owned by any single person, do not send request for information to this address. If you require additional information, please contact the person listed in this posting. CONTACT Bechtel National, Inc. 2435 Stevens Center Place Richland, WA 99354 Attn: Matthew Szendre Mailstop: MS12-2A Email: msszendr@bechtel.com
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/DOE/BNI/BNI/24590-QL-MRA-PY33-00008/listing.html)
- Record
- SN02626114-W 20111120/111118234510-398a61fed9e72e48b0febaf75cc5eb43 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |