Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF NOVEMBER 20, 2011 FBO #3648
SOLICITATION NOTICE

49 -- Constand Speed Drive Test Stands - CSD test stands

Notice Date
11/18/2011
 
Notice Type
Presolicitation
 
NAICS
336413 — Other Aircraft Parts and Auxiliary Equipment Manufacturing
 
Contracting Office
Department of the Air Force, Air Force Materiel Command, Tinker OC-ALC - (Central Contracting), 3001 Staff Drive, Ste 1AG76A, Tinker AFB, Oklahoma, 73145-3015
 
ZIP Code
73145-3015
 
Solicitation Number
FA8126-12-Q-0041
 
Archive Date
11/16/2012
 
Point of Contact
Thomas L. Long, Phone: 4057364477
 
E-Mail Address
thomas.long@tinker.af.mil
(thomas.long@tinker.af.mil)
 
Small Business Set-Aside
N/A
 
Description
Request for vendor qualified to provide B-52 CSD Test Stands. The government is seeking vendors, especially small businesses to provide K938-S7 B-52 Constant Speed Drive Test Stands. If at least two small businesses respond that they can provide the requirements, this procurement will be set a side. Please Email interest and brief (no more than 3 pages) qualification statement/past performance information to Thomas.long@tinker.af.mil. This procurement has not been funded, our intention is to identify qualified sources and make a set-a-side determination. The actual solicitation will be posted as FA8126-12-Q-0041 as soon as possible; we anticipate the posting date will be on or about 8 December 2011. Questions will not be answered. Background 1. The multi-aircraft Integrated Drive Generators (IDG), Constant Speed Drives (CSD), and their associated generators testing facility are located in Bldg. 2210 at the Oklahoma City Air Logistics Center (OC-ALC), Tinker Air Force Base, Oklahoma City, Oklahoma. The Fuel Accessory & Manufacture Production, Engineering Section (OC-ALC/76 CMXG) has a repair and test requirement that supports the highest priority aerospace weapon systems in the DOD inventory. The readiness of these systems is directly affected by 76 CMXG's ability to meet production, test and maintenance schedules to satisfy customer priority demands. To meet this requirement, it is necessary to install three new IDG/CSD test stands to support growing Air Force requirements. Scope 2. The contractor shall furnish and install "new" Integrated Drive Generator (IDG) / Constant Speed Drive (CSD) test stands. The new test stand's control system, DAQ system, operator consoles, safety implementations and software shall also match the government's current K938-S7 model test stand. The contractor is required to install the new test stand as a turnkey system. The contractor shall install a data acquisition system that produces and prints all of the existing test reports, graphs, and outputs exactly as produced by Tinker's current K938-S7 test stand. The test stand shall have the ability to test all the IDG/CSD's while utilizing all of the existing associated test adapters and equipment. The contractor shall supply all engineering, labor, materials, parts, tools, equipment, supplies, transportation, software and incidentals necessary to install the new test stands and system equipment. The new test stand shall have the ability of Depot testing multi-aircraft Integrated Drive Generators (IDG), Constant Speed Drives (CSD), and their associated generators and parts. The contractor shall be responsible for installation of utility supply up to 50 feet from the new test stand site to provided facility source. The new test stand control and instrumentation test systems shall be capable of performing manual and semi-automatic self-programming system testing. This requires the design, manufacture, and installation of performance data acquisition and control systems for computer based control and monitoring of the test stand's operational test parameters. The contractor shall also, provide training in the operation, maintenance, and calibration of the test systems. This training and equipment shall be used to perform post overhaul acceptance testing for a variety of CSD and IDG. The government shall supply the CSDs and IDGs for the acceptance testing. The new test stands will be located at Tinker Air Force Base, Oklahoma.
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/USAF/AFMC/OCALCCC/FA8126-12-Q-0041/listing.html)
 
Place of Performance
Address: Tinker AFB, Oklahoma, 73145, United States
Zip Code: 73145
 
Record
SN02626291-W 20111120/111118234719-3391d3d433e3333b27d7231feb6f4729 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.