SOLICITATION NOTICE
65 -- Portable Ultrasound Machine
- Notice Date
- 11/22/2011
- Notice Type
- Combined Synopsis/Solicitation
- Contracting Office
- 693 Neiman Street, Ft. Detrick, MD 21702
- ZIP Code
- 21702
- Solicitation Number
- FM568212720071
- Response Due
- 11/30/2011
- Archive Date
- 5/28/2012
- Point of Contact
- Name: Client Services, Title: Sourcing Agent, Phone: 1.877.9FEDBID, Fax: 703.442.7822
- E-Mail Address
-
clientservices@fedbid.com;
- Small Business Set-Aside
- Total Small Business
- Description
- This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, in conjunction with FAR 13.5, as applicable, and as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; bids are being requested and a written solicitation will not be issued.The solicitation number is FM568212720071 and is issued as an invitation for bids (IFB), unless otherwise indicated herein.The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-54. The associated North American Industrial Classification System (NAICS) code for this procurement is 423450 with a small business size standard of 100.00 employees.This requirement is a [ Small Business ] set-aside and only qualified offerors may submit bids.The solicitation pricing on www.FedBid.com will start on the date this solicitation is posted and will end on 2011-11-30 12:00:00.0 Eastern Time or as otherwise displayed at www.FedBid.com.FOB Destination shall be New Cumberland, PA 17070 The U.S. Army MEDCOM North Atlantic Regional Contracting Office requires the following items, Brand Name or Equal, to the following: LI 001, L05323 - SonoSite M-Turbo. SonoSite M-Turbo high-resolution, all-digital, 7.5-pound (3.0 kg) ultrasound system with 10.4 in. digital display. Standard features include Display Module, 2D gray scale with SonoMB Multi Beam Technology and Auto Gain, with SonoADAPT Tissue Optimization Technnology, M-mode, HIPAA compliance tool set, comprehensive application specific calculation packages, PC direct connectivity capability (through USB Memory Stick or via SiteLink - USB Cable ordered separately). Also includes battery, ultrasound gel and user guides. The M-Turbo combines the high performance of cart-based systems with the speed, flexibility and durability of hand-carried ultrasound. 8 GB of on-board Flash memory will retain enough data for over 40 standard exams(or 2,400 seconds of clips, 1,200 still frames and 40 report pages) even after power is turned off. The system supports USB media playback and connectivity is accomplished through one of two USB slots on the system, which allow for direct sharing of images (JPEG) and Clips (MPEG4) to a PC or Mac. M-Turbo's reliability and durability are backed by a five-year standard warranty, which is included in the price of the system. Software upgrades to the main system and transducer databases are both accomplished through one of the two USB ports on the system., 1, EA; LI 002, P07271 - M-Turbo Color Option - Olympic Mist (Silver)., 1, EA; LI 003, P12813 - Color Application Software Package M-Turbo. This package provides the following capabilities for the transducers that support these features: - Tissue Harmonic Imaging (THI), a capability in which the system transmits at one frequency and receives at a higher harmonic frequency to reduce noise and clutter and improve resolution.-SonoHD Imaging Technology, technology which significantly reduces speckle noise while enhancing tissue margins, thereby dramatically improving contrast and structural resolution.- Velocity color flow imaging provides the clinician with the color sensitivty to perform color Doppler examinations with all transducers during a clinical procedure.- PW Doppler is available on all transducers._ CW Doppler is a quantitative assessment of blood flow with Duplex imaging for higher flow velocities., 1, EA; LI 004, P08525 - Advanced OB/GYN Calculations. Advanced calculation package for obstetrics and gynecological imaging applications., 1, EA; LI 005, P07680 - C60X / 5-2 MHz Transducer Biopsy Compatible. C60x / 5-2 MHz multi-frequency, broadband, 60 mm curved array transducer for general purpose, abdominal, obstetric, gynecology and nerve exams. Supports 2D with SonoMB Multi Beam Technology and Auto Gain capabilities, SonoHD Imaging Technology, Tissue Harmonic Imaging, M-mode, Color Power Doppler, Velocity Color Flow Doppler and Pulsed Wave Doppler. Biopsy guide available. 1-meter drop-test durability. Maximum depth is 30 cm., 1, EA; LI 006, P07690 - ICTx / 8-5 MHz Transducer Biopsy Compatible. ICTx / 8-5 MHz intracavity curved array broadband 11 mm transducer for intracavity gynecological and obstetrical exams. Supports 2D with SonoMB Multi Beam Technology and Auto Gain capabilities, SonoHD Imaging Technology, M-mode, Color Power Doppler, Velocity Color Flow Doppler and Pulsed Wave Doppler, Biopsy guide available. Maximum depth is 10 cm., 1, EA; LI 007, L12163 - H-Universal Stand (M-Turbo Only). Ergonomic stand and mobile work platform for the M-Turbo system and transducers. Complete with power supply and DVI mini-dock., 1, EA; LI 008, P06293 - Sony Up 897 Md Black & White Video Printer. Medical grade, monochrome video printer with interface cables. Worlwide power (100V-240V, 50/60Hz) and video (NTSC/PAL). North American power cord supplied by manufacturer., 1, EA; LI 009, P07662 - User Guide M-Turbo. M-Turbo Ultrasound System User Guide, English., 1, EA; LI 010, P04764 - Triple Transducer Connect (TTC) w/quick disconnect. Three-transducer module for mobile docking system that allows connection of up to three (3) transducers simultaneously while the system is docked in the MDSm, MDSe, MDS Lite or H-Stand., 1, EA; LI 011, 5-YR-WARRANTY - 60 MONTHS - STANDARD COVERAGE WARRANTY. 60-months - standard coverage warranty., 1, EA; Solicitation and Buy Attachments ***Question Submission: Interested offerors must submit any questions concerning the solicitation at the earliest time possible to enable the Buyer to respond. Questions must be submitted by using the 'Submit a Question' feature at www.fedbid.com. Questions not received within a reasonable time prior to close of the solicitation may not be considered.*** For this solicitation, U.S. Army MEDCOM North Atlantic Regional Contracting Office intends to conduct an online competitive reverse auction to be facilitated by the third-party reverse auction provider, FedBid, Inc. FedBid has developed an online, anonymous, browser based application to conduct the reverse auction. An Offeror may submit a series of pricing bids, which descend in price during the specified period of time for the aforementioned reverse auction. U.S. Army MEDCOM North Atlantic Regional Contracting Office is taking this action in an effort to improve both vendor access and awareness of requests and the agency's ability to gather multiple, competed, real-time bids.All responsible Offerors that respond to this solicitation MUST submit the pricing portion of their bid using the online exchange located at www.FedBid.com. There is no cost to register, review procurement data or make a bid on www.FedBid.com.Offerors that are not currently registered to use www.FedBid.com should proceed to www.FedBid.com to complete their free registration. Offerors that require special considerations or assistance may contact the FedBid Helpdesk at 877-9FEDBID (877-933-3243) or via email at clientservices@fedbid.com. Offerors may not artificially manipulate the price of a transaction on www.FedBid.com by any means. It is unacceptable to place bad faith bids, to use decoys in the www.FedBid.com process or to collude with the intent or effect of hampering the competitive www.FedBid.com process.Should offerors require additional clarification, notify the point of contact or FedBid at 877-9FEDBID (877-933-3243) or clientservices@fedbid.com.Use of FedBid: Buyers and Sellers agree to conduct this transaction through FedBid in compliance with the FedBid Terms of Use. Failure to comply with the below terms and conditions may result in offer being determined as non-responsive. New Equipment ONLY; NO remanufactured or "gray market" items. All items must be covered by the manufacturer's warranty. Bid MUST be good for 90 calendar days after close of Buy. Shipping must be free on board (FOB) destination CONUS (Continental U.S.), which means that the seller must deliver the goods on its conveyance at the destination specified by the buyer, and the seller is responsible for the cost of shipping and risk of loss prior to actual delivery at the specified destination. Offeror must be registered in the Central Contractor Registration (CCR) database before an award can be made to them. If the offeror is not registered in the CCR, it may do so through the CCR website at http://www.ccr.gov. EFFECTIVE JAN 2005, all offerors are required to use ?Online Representations and Certifications Application (ORCA) to respond to federal solicitations. To register in ORCA, please go to www.bpn.gov/orca. You must be active in the Central Contractor Registration (www.ccr.gov) and have a Marketing Partner Identification Number (MPIN), to register in ORCA. Failure to register in ORCA may preclude an award being made to your company. No partial shipments are permitted unless specifically authorized at the time of award. The selected Offeror must comply with the following commercial item terms and conditions, which are incorporated herein by reference: FAR 52.212-1, Instructions to Offerors - Commercial Items, applies to this acquisition; FAR 52.212-3, Offeror Representations and Certifications - Commercial Items - the selected offeror must submit a completed copy of the listed representations and certifications; FAR 52.212-4, Contract Terms and Conditions - Commercial Items; FAR 52.212-5, Contract Terms and Conditions Required To Implement Statutes or Executive Orders-Commercial Items, paragraph (a) and the following clauses in paragraph (b): 52.222-21, 52.222-26, 52.222-35, 52.222-36, 52.222-37, 52.225-13, 52.232-34.
- Web Link
-
FBO.gov Permalink
(https://www.fbo.gov/spg/USA/MEDCOM/DADA15/FM568212720071/listing.html)
- Place of Performance
- Address: New Cumberland, PA 17070
- Zip Code: 17070-5002
- Zip Code: 17070-5002
- Record
- SN02627992-W 20111124/111122235224-f1217782367bf767617884fd705d59ca (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |