Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF DECEMBER 08, 2011 FBO #3666
SOLICITATION NOTICE

61 -- Transformer

Notice Date
12/6/2011
 
Notice Type
Combined Synopsis/Solicitation
 
NAICS
423610 — Electrical Apparatus and Equipment, Wiring Supplies, and Related Equipment Merchant Wholesalers
 
Contracting Office
M67400 MARINE CORPS REGIONAL CONTRACTING OFFICE FAR EAST FPO,
 
ZIP Code
00000
 
Solicitation Number
M6740012T0020
 
Response Due
12/15/2011
 
Archive Date
12/30/2011
 
Point of Contact
Minako Kinjo 011816117457841
 
E-Mail Address
Minako Kinjo
(minako.kinjo.ja@usmc.mil)
 
Small Business Set-Aside
N/A
 
Description
This is a combined synopsis / solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. This procurement is not a small business set-aside; any responsible source may submit an offer. This announcement constitutes the only solicitation; quotes are being requested and a separate written solicitation will not be issued. Solicitation number M67400-12-T-0020 applies and is issued as a Request for Quotation. This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-54and Defense Acquisition Circular 91-13. The NAICS code is 423610. The Government intends to issue an order to the responsible offeror whose quote is the most advantageous to the Government considering Technical acceptability and Price. The offeror ™s quote shall contain all requested products as the contract award will be made in aggregate to one offeror. Therefore, any offer received without all products priced will be excluded from competition. Shipping Point -Stateside delivery and local delivery is acceptable: -Delivery point from local offers is to Bldg. 362 Camp Foster, Chatan-town, Okinawa, Japan 901-2100. -Delivery point from offers within CONUS is to Defense Logistics Agency, Defense Distribution Depot San Joaquin, Tracy Depot, Bldg. 30 CCP, 25600 Chrisman Road, Tracy, CA 95376. CLIN0001 Qty: 3EA Mfg: Cooper Power System P/N:201-10 Description: TRANSFORMER, POWER; OVERHEAD, POLE-MOUNT, 167 kVA, SINGLE-PHASE, CONVENTIONAL, IEE C57.12.20 AND AS SPECIFIED HEREIN, LIQUID INSULATED, NO PCB ™s BY JEGS REQUIREMENTS (SEE PARAGRAPH 3 BELOW), TWO BUSHING, 13,800 V PRIMARY (FOR 13,800 V DELTA THREE-PHASE BANK CONNECTION; 95 kV BIL), 120/240 V SECONDARY. 1. TRANSFORMER. SELF-COOLED, 65 DEGREES C CONTINUOUS TEMPERATURE RISE, TWO WINDING, 60 Hz. 2. INSULATING LIQUID. LESS-FLAMMABLE TRANSFORMER LIQUIDS: NFPA 70 AND FM P7825 FOR LESS-FLAMMABLE LIQUIDS HAVING A FIRE POINT NOT LESS THAN 300 DEGREES C TESTED PER ASTM D 92 AND A DIELECTRIC STRENGTH NOT LESS THAN 33 kV TESTED PER ASTM D 877. PROVIDE IDENTIFICATION OF TRANSFORMER AS śNON-PCB ť. THE FLUID SHALL BE A BIODEGRADABLE ELECTRICAL INSULATING AND COOLING LIQUID CLASSIFIED BY UL AND APPROVED BY FM AS śLESS FLAMMABLE ť FLUIDS. THE FLUID SHALL MEET THE FOLLOWING PROPERTIES: (1) POUR POINT: ASTM D 97, LESS THAN - 15 DEGREES C; (2) AQUATIC BIODEGRADATION: EPA 712-C-98-075, 100 % AND (3) TROUT TOXICITY: OECD TEST 203, ZERO MORTALITY OF EPA 600/4-90/027F, PASS. 3. PCB CONTENT CERTIFICATION: THE MANUFACTURER MUST CERTIFY THAT THE TRANSFORMER IS śNON-PCB ť. THE FLUID SHALL CONTAIN LESS THAN 0.1 (ZERO POINT ONE) ppm OF PCB ™s; THIS LIMIT IS A JEGS (JAPAN ENVIRONMENTAL GOVERNING STANDARDS) REQUIREMENT THAT APPLIES TO MARINE CORPS BASE JAPAN. THE CERTIFICATION SHALL SHOW śACTUAL LABORATORY TEST METHOD DETECTION LIMITS ť. 4. NAMEPLATE: SHALL INDICATE śMANUFACTURER ™S NAME AND TYPE OF FLUID ť AND śLESS THAN 0.1 ppm PCB ™s ť. 5. TAPS: PROVIDE FOUR 2-1/2 PERCENT FULL CAPACITY TAPS, 2 ABOVE AND 2 BELOW RATED PRIMARY VOLTAGE. TAP CHANGER SHALL HAVE EXTERNAL HANDLE. 6. CORROSION PROTECTION: PAINT COATING SYSTEM SHALL COMPLY WITH IEE C57.12.28. FINISH COAT SHALL BE LIGHT GRAY, ANSI COLOR No. 70. 7. SHOW TRANSFORMER kVA CAPACITY USING 65 mm 2-1/2 INCH ARABIC NUMERALS PLACED NEAR THE LOW-VOLTAGE BUSHINGS. MFR.: COOPER POWER SYSTEMS, MODEL: TWO HIGH VOLTAGE BUSHINGS SINGLE-PHASE OVERHEAD DISTRIBUTION TRANSFORMER, CATALOG SECTION 201-10 (167 kVA), CLIN0002 Qty: 3EA Mfg: Cooper Power System P/N:201-10 TRANSFORMER, POWER; OVERHEAD, POLE-MOUNT, 167 kVA, SINGLE-PHASE, CONVENTIONAL, IEE C57.12.20 AND AS SPECIFIED HEREIN, LIQUID INSULATED, NO PCB ™s BY JEGS REQUIREMENTS (SEE PARAGRAPH 3 BELOW), TWO BUSHING, 13,800 V PRIMARY (FOR 13,800 V DELTA THREE-PHASE BANK CONNECTION; 95 kV BIL), 240/480 V SECONDARY. 1. TRANSFORMER. SELF-COOLED, 65 DEGREES C CONTINUOUS TEMPERATURE RISE, TWO WINDING, 60Hz. 2. INSULATING LIQUID. LESS-FLAMMABLE TRANSFORMER LIQUIDS: NFPA 70 AND FM P7825 FOR LESS-FLAMMABLE LIQUIDS HAVING A FIRE POINT NOT LESS THAN 300 DEGREES C TESTED PER ASTM D 92 AND A DIELECTRIC STRENGTH NOT LESS THAN 33 kV TESTED PER ASTM D 877. PROVIDE IDENTIFICATION OF TRANSFORMER AS śNON-PCB ť. THE FLUID SHALL BE A BIODEGRADABLE ELECTRICAL INSULATING AND COOLING LIQUID CLASSIFIED BY UL AND APPROVED BY FM AS śLESS FLAMMABLE ť FLUIDS. THE FLUID SHALL MEET THE FOLLOWING PROPERTIES: (1) POUR POINT: ASTM D 97, LESS THAN - 15 DEGREES C; (2) AQUATIC BIODEGRADATION: EPA 712-C-98-075, 100 % AND (3) TROUT TOXICITY: OECD TEST 203, ZERO MORTALITY OF EPA 600/4-90/027F, PASS. 3. PCB CONTENT CERTIFICATION: THE MANUFACTURER MUST CERTIFY THAT THE TRANSFORMER IS NON-PCB. THE FLUID SHALL CONTAIN LESS THAN 0.1 (ZERO POINT ONE) ppm OF PCB ™s; THIS LIMIT IS A JEGS (JAPAN ENVIRONMENTAL GOVERNING STANDARDS) REQUIREMENT THAT APPLIES TO MARINE CORPS BASE JAPAN. THE CERTIFICATION SHALL SHOW śACTUAL LABORATORY TEST METHOD DETECTION LIMITS ť. 4. NAMEPLATE: SHALL INDICATE śMANUFACTURER ™S NAME AND TYPE OF FLUID ť; AND śLESS THAN 0.1 ppm PCB ™s ť. 5. TAPS: PROVIDE FOUR 2-1/2 PERCENT FULL CAPACITY TAPS, 2 ABOVE AND 2 BELOW RATED PRIMARY VOLTAGE. TAP CHANGER SHALL HAVE EXTERNAL HANDLE. 6. CORROSION PROTECTION: PAINT COATING SYSTEM SHALL COMPLY WITH IEE C57.12.28. FINISH COAT SHALL BE LIGHT GRAY, ANSI COLOR No. 70. 7. SHOW TRANSFORMER kVA CAPACITY USING 65 mm 2-1/2 INCH ARABIC NUMERALS PLACED NEAR THE LOW-VOLTAGE BUSHINGS. MFR.: COOPER POWER SYSTEMS, MODEL: TWO HIGH VOLTAGE BUSHINGS SINGLE-PHASE OVERHEAD DISTRIBUTION TRANSFORMER, CATALOG SECTION 201-10 (167 kVA), The following Provisions apply to this acquisition: FAR 52.204-7 Central Contractor Registration FAR 52.209-6 Protecting the Government s Interest When Subcontracting with Contractors Debarred, Suspended, or Proposed for Debarment, FAR 52.211-6 Brand Name or Equal (Aug 1999) FAR 52.211-17 Delivery of Excess Quantities FAR 52.212-1 Instructions to Offerors-Commercial Items (Jun 2008), FAR 52.212-2 Evaluation-Commercial Items (Jan 1999), FAR 52.212-3 Offeror Representations and Certification Commercial Items (FEB 2009), FAR 52.212-4 Contract Terms and Conditions Commercial Items (MAR 2009), FAR 52.212-5 (Dev) Contract Terms and Conditions Required to Implement Statutes or Executive Orders Commercial Items (SEP 2009), FAR 52.232-23 Assingment of Claim FAR 52.232-33 Payment by Electronic Funds Transfer (Oct 2003), DFAR 252.203-7000 Requirement Relating to Compensation of Former DoD officials DFAR 252.203-7002 Requirement to Inform employees of Whistleblower Rights DFAR 252.204-7003 Control of Government Personnel Work Product DFAR 252.204-7004, Alternate A, Central Contractor Registration, DFAR 252.211-7003 Item Identification and Valuation (AUG 2008), DFAR 252.211-7006 Radio Frequency Identification DFAR 252.212-7001 Contract Terms and Conditions (JAN 2009) DFAR 252.225-7021 Trade Agreements DFAR 252.229-7000 Invoices Exclusive of Taxes or Duties DFAR 252.232-7003 Electronic Submission of Payment Requests and Receiving Report. DFAR 252.232-7010 Levies on Contract Payments DFAR 252.243-7001 Pricing of Contract Modifications. Responsible quoter must be active in the Central Contractor Registration in accordance with DFARS 252.204-7004 Alternate A (Sep 2007). DUNS, TIN, and CAGE Code must be written on submitted quote. Payment shall be made electronically by utilizing WAWF. Full text of these provisions can be accessed on-line at http://www.arnet.gov/far, http://farsite.hill.af.mil/vfdfara.htm The following information must be provided with this quotation: 1.Commercial and government entity code (Cage). 2.Taxpayer identification number (Tin). 3.Data universal numbering system (Duns). 4.Estimated Delivery Date: 5.Specs and picture of quoted item 6.Catalog cut or data showing type (Two bushing, etc.), Capacity (kVA) and voltages; 7.PCB content certification (See paragraph 3 above Item description) 8.Name plate data (See paragraph 4 above Item description). Remit to Address Quotes can be faxed to 011816117450959 or e-mailed to minako.kinjo.ja@usmc.mil. Questions can be addressed by email to Minako Kinjo by 12 Dec 2011, 6:00 P.M. (EST). Quotes must be received no later than, 15 Dec 2011, 06 :00PM Eastern Standard Time(EST)
 
Web Link
FBO.gov Permalink
(https://www.fbo.gov/spg/DON/USMC/M67400/M6740012T0020/listing.html)
 
Record
SN02634715-W 20111208/111206234901-f60f5921b1ab81bf9f838cc06154a136 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.